• Title/Summary/Keyword: electrolyte concentration

Search Result 685, Processing Time 0.02 seconds

Effect of Electrolyte Concentration on Water Permeation in Protective Coatings (방식도막에 있어서 물의 침투에 대한 전해질 용액의 영향)

  • 박진환
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.206-212
    • /
    • 1998
  • The water permeation in protective coatings, which may greatly influence the corrosion protective property of these coatings, was studied using the electrochemical impedance spectroscopy technique. During the absorption of water in protective coatings immersed in electrolyte solution, the change of coating capacitance with concentration of electrolyte was determined from impedance measurements. When water absorption or desorption of coatings occured by exposing the coatings to electrolyte solutions of different concentration, increase in impedance caused by desorption of water was found to be higher in the case of thicker film. The amount of water absorbed in coatings changed with concentration of electrolyte. The water taken up in coatings from the solution of lower electrolyte concentration was deserted by contact with the solution of higher concentration. The uptake of water in protective coatings varied depending on the type of coating ingredient especially binder.

  • PDF

Effect of Electrolyte Concentration on Surfactant-Enhanced Electrokinetic Removal of Phenanthrene

  • 이유진;박지연;김상준;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.346-349
    • /
    • 2004
  • Surfactant-enhanced electrokinetic (EK) process was investigated to remove polycyclic aromatic hydrocarbons (PAHs) from low-permeable soils. Phenanthrene and kaolinite were selected as a representative PAH and a model soil, respectively. A nonionic surfactant Tergitol 15-S-12 was applied to improve the solubility of phenanthrene and sodium chloride was used as an electrolyte at the various concentrations from 0.001 to 0.1M. The addition of electrolyte affected both the removal efficiency and operation cost. When electrolyte was introduced, the electrical potential gradient became low and thus power consumption was reduced. However, as electrolyte concentration increased, the electroosmotic flow also decreased, so the removal efficiency of contaminant decreased. Therefore, the removal efficiency and power consumption should be considered simultaneously to determine the iptimum surfactant concentration, so a relatively lower concentration of electrolyte than certain value is desired.

  • PDF

Effects of Electrolyte Concentration and Relative Cathode Electrode Area Sizes in Titania Film Formation by Micro-Arc Oxidation

  • Lee, Yong-K.;Lee, Kang-Soo
    • Corrosion Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.171-174
    • /
    • 2010
  • MAO (micro-arc oxidation) is an eco-friendly convenient and effective technology to deposit high-quality oxide coatings on the surfaces of Ti, Al, Mg and their alloys. The roles of the electrolyte concentration and relative cathode electrode area sizes in the grown oxide film during titanium MAO were investigated. The higher the concentration of the electrolyte, the lower the $R_{total}A$ value. The oxide film produced by the lower concentration of the electrolyte is thinner and less uniform than the film by the higher concentration, which is thick and porous. The cathode area size must be bigger than the anode area size in order to minimize the voltage drop across the cathode. The ratio of the cathode area size to the anode area size must be bigger than 8. Otherwise, the cathode will be another source for voltage drop, which is detrimental to and slows down the oxide growth.

Characteristics of electrodeposited bismuth telluride thin films with different crystal growth by adjusting electrolyte temperature and concentration

  • Yamaguchi, Masaki;Yamamuro, Hiroki;Takashiri, Masayuki
    • Current Applied Physics
    • /
    • v.18 no.12
    • /
    • pp.1513-1522
    • /
    • 2018
  • Bismuth telluride ($Bi_2Te_3$) thin films were prepared with various electrolyte temperatures ($10^{\circ}C-70^{\circ}C$) and concentrations [$Bi(NO_3)_3$ and $TeO_2:1.25-5.0mM$] in this study. The surface morphologies differed significantly between the experiments in which these two electrodeposition conditions were separately adjusted even though the applied current density was in the same range in both cases. At higher electrolyte temperatures, a dendrite crystal structure appeared on the film surface. However, the surface morphology did not change significantly as the electrolyte concentration increased. The dendrite crystal structure formation in the former case may have been caused by the diffusion lengths of the ions increasing with increasing electrolyte temperature. In such a state, the reactive points primarily occur at the tops of spiked areas, leading to dendrite crystal structure formation. In addition, the in-plane thermoelectric properties of $Bi_2Te_3$ thin films were measured at approximately 300 K. The power factor decreased drastically as the electrolyte temperature increased because of the decrease in electrical conductivity due to the dendrite crystal structure. However, the power factor did not strongly depend on the electrolyte concentration. The highest power factor [$1.08{\mu}W/(cm{\cdot}K^2$)] was obtained at 3.75 mM. Therefore, to produce electrodeposited $Bi_2Te_3$ films with improved thermoelectric performances and relatively high deposition rates, the electrolyte temperature should be relatively low ($30^{\circ}C$) and the electrolyte concentration should be set at 3.75 mM.

Effects of Electrolyte Concentration on Electrochemical Properties of an Iron Hexacyanoferrate Active Material (헥사시아노 철산철 활물질의 전기화학적 특성에 미치는 전해질 농도의 영향)

  • Yang, Eun-Ji;Lee, Sangyup;Nogales, Paul Maldonado;Jeong, Soon-Ki
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.2
    • /
    • pp.117-123
    • /
    • 2021
  • The effects of electrolyte concentration on the electrochemical properties of Fe4[Fe(CN6)]3(FeHCF) as a novel active material for the electrode of aqueous zinc-ion batteries was investigated. The electrochemical reactions and structural stability of the FeHCF electrode were significantly affected by the electrolyte concentration. In the electrolyte solutions of 1.0-7.0 mol dm-3, the charge-discharge capacities increased with increasing electrolyte concentration, however gradually decreased as the cycle progressed. On the other hand, in the 9.0 mol dm-3 electrolyte solution, the initial capacity was relatively small, however showed good cyclability. Additionally, the FeHCF electrode after five cycles in the former electrolyte solutions, had a change in crystal structure, whereas there was no change in the latter electrolyte solution. This suggests that the performance of the FeHCF electrode is greatly influenced by the hydration structure of zinc ions present in electrolyte solutions.

Effect of PEO Process Conditions on Oxidized Surface Properties of Mg alloy, AZ31 and AZ91. II. Electrolyte (PEO 처리조건에 따른 마그네슘 합금 AZ31과 AZ91의 산화표면피막특성에 대한 연구. II. 전해질의 영향)

  • Ham, Jae-Ho;Jeon, Min-Seok;Kim, Yong-Nam;Shin, Hyun-Gyoo;Kim, Sung Youp;Kim, Bae-Yeon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.4
    • /
    • pp.225-230
    • /
    • 2016
  • Effect of electrolyte composition and concentration on PEO coating layer were investigated. Mg alloy, Surface of AZ31 and AZ91 were oxidized using PEO with different electrolyte system, Na-P and Na-Si. and applied voltage and concentration. We measured thickness, roughness, X-ray crystallographic analysis and breakdown voltage of the oxidized layer. When increasing concentration of electrolyte, the thickness of oxide layer also increased too. And roughness also increased as concentration of electrolyte increasing. Breakdown voltage of coated layer showed same behavior, the voltage goes high as increasing thickness of coating layer, as increasing concentration of electrolyte, and increasing applied voltage of PEO. $Mg_2SiO_4$ phase were observed as well as MgO.

Electrochemical Degradation of Phenol by Electro-Fenton Process (전기-펜톤 공정에 의한 페놀의 전기화학적 분해)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.3
    • /
    • pp.201-208
    • /
    • 2009
  • Oxidation of phenol in aqueous media by electro-Fenton process using Ru-Sn-Sb/graphite electrode has been studied. Hydrogen peroxide was electrically generated by reaction of dissolved oxygen in acidic solutions containing supporting electrolyte and $Fe^{2+}$ was added in aqueous media. Phenol degradation experiments were performed in the presence of electrolyte media at pH 3. Effect of operating parameters such as current, electrolyte type (NaCl, KCl and $Na_2SO_4$) and concentration, $Fe^{2+}$ concentration, air flow rate and phenol concentration were investigated to find the best experimental conditions for achieving overall phenol removal. Results showed that current of 2 A, NaCl electrolyte concentration of 2g/l, 0.5M concentration of $Fe^{2+}$, air flow rate of 1l/min were the best conditions for mineralization of the phenol by electro-Fenton.

Operational conditions of electrochemical oxidation process for removal of cyanide (CN-) in real plating wastewater

  • Zhao, Xin;Jang, Minsik;Cho, Jin Woo;Lee, Jae Woo
    • Membrane and Water Treatment
    • /
    • v.11 no.3
    • /
    • pp.217-222
    • /
    • 2020
  • An electrochemical oxidation process was applied to remove cyanide (CN-) from real plating wastewater. CN- removal efficiencies were investigated under various operating factors: current density and electrolyte concentration. Electrolyte concentration positively affected the removal of both CN- and Chemical Oxygen Demand (COD). As the electrolyte concentration increased from 302 to 2,077 mg Cl-/L, removal efficiency of CN- and COD increased from 49.07% to 98.30% and from 23.53% to 49.50%, respectively, at 10 mA/㎠. Current density affected the removal efficiency in a different way. As current density increased at a fixed electrolyte concentration, CN- removal efficiency increased while COD removal efficiency decreased, this is probably due to lowered current efficiency caused by water electrolysis.

Effect of Electrolyte Concentration Difference on Hydrogen Production during PEM Electrolysis

  • Sun, Cheng-Wei;Hsiau, Shu-San
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.99-108
    • /
    • 2018
  • Proton exchange membrane (PEM) water electrolysis systems offer several advantages over traditional technologies including higher energy efficiency, higher production rates, and more compact design. In this study, all the experiments were performed with a self-designed PEM electrolyser operated at 1 atm and $25^{\circ}C$. Two types of electrolyte were used: (i) potassium hydroxide (KOH), and (ii) sulfuric acid ($H_2SO_4$). In the experiments, the voltage, current, and time were measured. The concentration of the electrolyte significantly affected the electrolyser performance. Overall the best case was with 15 wt% $H_2SO_4$ at the anode channel and 20 wt% at the cathode channel with. In addition, increasing the difference in concentration of the sulfuric acid had an effect on the diffusion. The diffusion flux became larger when the difference in concentration became larger, increasing electrolyser efficiency without the addition of extra energy.

Effect of the Concentration of Suspension and Electrolyte on Zeta Potential (현탁액과 전해질의 농도가 제타전위에 미치는 영향)

  • 정상진;이승인;임형미
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.3
    • /
    • pp.293-300
    • /
    • 2003
  • It was investigated that effect of suspension and electrolyte concentrations on zeta potential of alumini suspension and Iso-Electric Point(I.E.P.). The alumina powders in 0.1∼l $\mu\textrm{m}$ particle size distribution, and the electrolyte NH$_4$NO$_3$ were used for preparing the suspension and electrophoresis method was used for measuring zeta potential in this work. As the concentration of suspension was increased, zeta potential and the I.E.P. were increased, respectively. On the other hand, as the electrolyte concentration was increased, the I.E.P. was decreased. As a result of this work, the best condition for measuring zeta potential was the 0.01 wt% and 10 mM of the suspension and the electrolyte concentration, respectively.