• Title/Summary/Keyword: electrode configuration

Search Result 196, Processing Time 0.025 seconds

The Numerical Analysis of Two-Dimensional Electrokinetic Remediation Characteristics Dependent on Electrode Configurations (전극배치에 따른 2차원적 동전기 정화 특성의 수치해석)

  • Kim, Soo Sam;Han, Sang Jae;Kim, Byung Ill
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5C
    • /
    • pp.291-301
    • /
    • 2006
  • In this study the characteristics of electrokinetic remediation, which is dependent on a various electrode configuration, was predicted from 2-D numerical analysis program (HERO-2D). Based on the predicted results for one dimensional and two dimensional electrode configurations, the optimized electrode configuration was determined by analyzing remediation efficiency, consumed electric power, installation cost of electrode and so on. When proposed electrode configurations were applied for in-situ remediation of the soils contaminated by heavy metals, the electrode configuration of high remediation efficiency should be chosen in case the high removal effect would be required, and one dimensional electrode configuration should be chosen in case the hard field works would be expected. Because the rectangular electrode configuration is better than others for consumed electric power, remediation efficiency per unit power, installation cost of electrode and so on, it can obtain the best results for the cost reduction.

Measurement of Soot Nano-Particle Using LIIM(Laser-Induced Ion Mobility) (LIIM(Laser-Induced Ion Mobility) 계측을 이용한 매연 나노입자 측정)

  • Lee, Eui-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.9
    • /
    • pp.1110-1116
    • /
    • 2004
  • Experimental measurements of laser-induced ion mobility(LIIM) were performed for ethene/air premixed flames operated near the soot inception point. Soot was ionized using a pulsed laser operated at 532 nm. The ionization signal was collected with a tungsten electrode located in the post-flame region. ionization signals were collected using both a single electrode and dual electrode configuration. Prior LIIM studies have focused on the use of a single biased electrode to generate the electric field, with the burner head serving as the path to ground. In many practical combustion systems, a path to ground is not readily available. To apply the LIIM diagnostic to these geometries, a dual electrode geometry must be employed. The influence of electrode configuration, flame equivalence ratio, and flame height on ionization signal detection was determined. The efficacy of the LIIM diagnostic to detect soot inception in the post-flame region of a premixed flame using a dual electrode configuration was investigated. For the different dual electrode configurations tested, the dual parallel electrode geometry was observed to be most sensitive to detect the soot inception point in a premixed flame.

A study on the discharge characteristics of liquid nitrogen using at cryogenic cable (극저온 전력케이블을 액체질소에 대한 방전특성에 관한 연구)

  • 이현동;주재현;박원주;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.125-129
    • /
    • 1996
  • This study describes that electrical breakdown of liquid nitrogen which is influenced with bubble has been investigated as liquid nitrogen is used coolant of high temperature(T/sub c/) superconductivity. In order to investigate breakdown of liquid nitrogen, we formed electrode system of parallel and vertical configuration toward gravitutional direction. In case of changing with electrode configuration of equal electrode and gap spacing in uniform and nonuniform electric field bubble behavior is changed. In result of that, breakdown voltage is changed. Therefore, this study proved that electrode configuration must be formed the smallest existing probability of bubble between two electrodes in order to increase breakdown strength of liquid nitrogen at atmosphere pressure.

  • PDF

An improved electrode structure of the Patterned Vertical Alignment Liquid Crystal Cell for high optical property

  • Choi, Yong-Hyun;Son, Jung-Hee;Yang, Jin-Seok;Ji, Seung-Hoon;Lee, Gi-Dong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.502-505
    • /
    • 2007
  • In this paper we propose a novel electrode structure for high transmittance in the Patterned Vertical Alignment (PVA) LC cell. Normally, the transmittance of PVA LC cell is depended on the shape of the electrode and cell gap. We studied the area decreasing the transmittance through the electrode structure for wide viewing angle and proposed new electrode design to change LC director configuration in the area. We use the 'TechWiz LCD' for calculation of the director configuration and optical characteristics. We show the comparison of the calculated optical transmittance between the conventional PVA mode and the proposed PVA mode. From the results, we confirm that the optical transmittance of the proposed structure of the PVA cell becomes higher.

  • PDF

Proposition for 4 Channel Frontal Lobe Electrode Configuration and Study on EOG Removal from Measured EEG (4채널 전두엽 전극 배치법의 제안과 측정된 뇌파에서의 안전도 제거에 관한 연구)

  • 신수인;조진호;김명남
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.1
    • /
    • pp.167-175
    • /
    • 2003
  • In this paper, a new electrode configuration and EOG removal method are proposed in order to measure EEG effectively on the frontal lobe and remove EOG in the measured raw EEG. The method of measuring EEG is proposed using four electrodes and a ground electrode on the frontal lobe with a reference electrode at the left earlobe. And also, the separation method using ICA is proposed for EOG removal from the measured EEG, Through the experiments of measuring EEG it was demonstrated that a subject can attach the electrodes by himself easily to measure his own EEG without any assistant and the proposed methods were suitable for removing EOG signal from the measured EEG.

  • PDF

Design of a Low-cost Active Dry Electrode Module for Single Channel EEG Recording

  • Byeon Jong-Gil;Jin Kyung-Soo;Park Byoung-Woo
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.1
    • /
    • pp.49-54
    • /
    • 2005
  • This paper presents a design of 1-channel active dry electrode module for EEG from one's forehead. The IA(instrumentation amplifier) circuit inside the module is based on the configuration sown on the paper MettingVanRijn et al. We analyze the IA circuit to find out the related equation, and then compare its simulated characteristic with the result obtained from the real active dry electrode circuit. With the active dry electrode and the wet(Ag/AgCI) electrode connected to the separated analog processing module on one's forehead at the same time, their real time and FFT outputs of EEG are examined for comparison. The active dry electrode module has advantages over the wet electrode and its analog processing module: 1) The size of the analog processing circuit of the active dry electrode module is smaller than that of existing EEG analog processing module; 2) the total cost required to make the proposed analog processing circuit is much lower than that of the existing circuit, since the designed circuit needs smaller parts; 3) the electrical characteristic is comparable to the general EEG analog processing module even if the designed module has simpler circuit configuration.

Optimum electrode selection for measuring the abdominal pressure using bio-impedance method (비침습적 복압 측정을 위한 생체 임피던스 전극의 최적 위치 선정)

  • An, Yang-Su;Kim, Keo-Sik;Song, Chul-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.46-48
    • /
    • 2007
  • In this study, we determined the optimum electrode pair for measuring the abdominal pressure using bio-impedance method. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified using values of impedance change, correlation coefficient and SNR. Our results showed the optimum electrode pair (1, 9) which could detect impedance changes due to an increase of the intensity of the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2$+0.0620x+0.6958, respectively. It demonstrated that the abdominal pressure could be measured non-invasively and simply using bio-impedance method. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of abdominal pressure by ambulatory urodynamics monitoring study.

  • PDF

Numerical Analysis of Discharge in Wire ion Plasma Source (입자법을 이용한 와이어.이온.플라즈마원의 해석)

  • 송태헌;고광철;강형부
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.369-372
    • /
    • 1997
  • Wire Ion Plasma Source (WIPS) is a plasma device which has a thin wire anode, a coaxially-set cylindrical cathode and electrodes located in both ends of the cylinder. The potential between the anode and cathode changes logarithmically by this electrode configuration. This electrode configuration enables high-density plasma to produce even at a low anode voltage. Since the electrode configuration is axially symmetric and long. plasma with axially uniform number density can be produced. Using particle-in-cell(PIC) and Monte Carlo collision(MCC), we investigate the traiectory of electrons and the characteristics of D.C. discharge in Wire ton Plasma Source.

  • PDF

Modeling and performance evaluation of a piezoelectric energy harvester with segmented electrodes

  • Wang, Hongyan;Tang, Lihua;Shan, Xiaobiao;Xie, Tao;Yang, Yaowen
    • Smart Structures and Systems
    • /
    • v.14 no.2
    • /
    • pp.247-266
    • /
    • 2014
  • Conventional cantilevered piezoelectric energy harvesters (PEHs) are usually fabricated with continuous electrode configuration (CEC), which suffers from the electrical cancellation at higher vibration modes. Though previous research pointed out that the segmented electrode configuration (SEC) can address this issue, a comprehensive evaluation of the PEH with SEC has yet been reported. With the consideration of delivering power to a common load, the AC outputs from all segmented electrode pairs should be rectified to DC outputs separately. In such case, theoretical formulation for power estimation becomes challenging. This paper proposes a method based on equivalent circuit model (ECM) and circuit simulation to evaluate the performance of the PEH with SEC. First, the parameters of the multi-mode ECM are identified from theoretical analysis. The ECM is then established in SPICE software and validated by the theoretical model and finite element method (FEM) with resistive loads. Subsequently, the optimal performances with SEC and CEC are compared considering the practical DC interface circuit. A comprehensive evaluation of the advantageous performance with SEC is provided for the first time. The results demonstrate the feasibility of using SEC as a simple and effective means to improve the performance of a cantilevered PEH at a higher mode.

Electrical Characterization of Electronic Materials Using FIB-assisted Nanomanipulators

  • Roh, Jae-Hong;You, Yil-Hwan;Ahn, Jae-Pyeong;Hwang, Jinha
    • Applied Microscopy
    • /
    • v.42 no.4
    • /
    • pp.223-227
    • /
    • 2012
  • Focused Ion Beam (FIB) systems have incorporated versatile nanomanipulators with inherent sophisticated machining capability to characterize the electrical properties of highly miniature components of electronic devices. Carbon fibers were chosen as a model system to test the applicability of nanomanipulators to microscale electronic materials, with special emphasis on the direct current current-voltage characterizations in terms of electrode configuration. The presence of contact resistance affects the electrical characterization. This resistance originates from either i) the so-called "spreading resistance" due to the geometrical constriction near the electrode - material interface or ii) resistive surface layers. An appropriate electrode strategy is proposed herein for the use of FIB-based manipulators.