• Title/Summary/Keyword: electrical resistivity test

Search Result 284, Processing Time 0.028 seconds

Study on the Thermal Degradation Properties of Epoxy Resin for the Cast Resin Transformer (몰드변압기용 에폭시 수지의 열 열화 특성에 관한 연구)

  • Nam, K.D.;Jung, J.I.;Huh, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1572-1574
    • /
    • 2000
  • In this paper, study on the properties of the thermal degradated epoxy resin which is used in cast resin transformer is performed to investigate the problems of the decreasing insulation characteristics and crack in the cast resin transformer. In the test, contact angle, weight loss, surface resistivity and relative dielectric constant are measured. As the results of the above measurements, the epoxy resin has increased to 150$^{\circ}C$ in the contact angle and surface resistivity but at the above 150$^{\circ}C$ the values have decreased. The relative dielectric constants have increased in the thermal treated samples with the degradation temperature. Consequently, the insulation properties of the epoxy resin which is used in cast resin transformer have increased by the 150$^{\circ}C$ but decreased in the above 150$^{\circ}C$.

  • PDF

Effect of Steel Fiber Distribution in Steel Fiber-reinforced Concrete on Surface Electrical Resistivity (강섬유 보강콘크리트의 강섬유 분산이 표면전기저항에 미치는 영향)

  • Kim, Seong Do;Moon, Do Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.1
    • /
    • pp.106-113
    • /
    • 2013
  • One of feasible non-destructivity test methods for evaluation of concrete permeability is the measurement of surface resistivity. But the application to steel fiber-reinforced concrete has been limited because mis-evaluation could be caused by the steel fibers in concrete. In this study, the effect of fiber distribution on surface electrical resistivity of steel fiber-reinforced concrete was investigated through experimental program. Resistivity was measured three times on four surfaces in three rectangular and circular specimens with 0.5%, 1% and 1.5% steel fibers by volume and compared each other. The results obtained from circular specimens were consistent compared to those from rectangular specimens. And the results demonstrated that the effect of fiber distribution on surface resistivity was not significant compared to that of mixing ratio of steel fibers. In conclusion, this non-destructive testing method using measurement of surface resistivity could be used for SFRC within 0.5% steel fibers by volume.

Relationship between Hydraulic Conductivity and Electrical Resistivity of Standard Sand and Glass Bead (표준사와 유리구슬을 이용한 수리전도도와 전기비저항의 관계)

  • Kim, Soodong;Park, Samgyu;Hamm, Se-Yeong
    • Economic and Environmental Geology
    • /
    • v.46 no.3
    • /
    • pp.215-220
    • /
    • 2013
  • We estimated the hydraulic conductivity of the sediments using constant-head permeability tests and electrical resistivity measurements with Jumoonjin standard sand of a uniform size and glass beads of different grain sizes. In this study, we determined the variations of the porosity, the hydraulic conductivity, and the resistivity in case 1 (changing the packing of the Jumoonjin standard sand) and in case 2 (varying the size of the glass beads). The results of case 1 showed that the hydraulic conductivity decreased with an increase in the electrical resistivity. This occurred because the sand grain while packing became rhombohedral with the a decrease of both the pore size and porosity. The results of the case 2 showed that the hydraulic conductivity increased due to the increase in the pore size as caused by the increased glass bead size. In addition, the porosity decreased and the electrical resistivity increased. Therefore, the relationship between the hydraulic conductivity and the electrical resistivity is negatively proportional as regards the grain packing with a change from cubic to rhombohedral whereas this relationship is positively proportional to the increase in the grain size.

Study on Electrical Resistivity Pattern of Soil Moisture Content with Model Experiments (토양의 함수율에 따른 전기비저항 반응 모형 실험 연구)

  • Ji, Yoonsoo;Oh, Seokhoon;Lee, Heui Soon
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.2
    • /
    • pp.79-90
    • /
    • 2013
  • Geophysical investigation in non-destructive testing is economically less expensive than boring testing and providing geotechnical information over wide-area. But, it provides only limited geotechnical information, which is hardly used to the design. Accordingly, we performed electrical resistivity experiments on large scale of soil model to analyze the correlation between electrical resistivity response and soil water contents. The soils used in the experiments were the Jumunjin standard sand and weathered granite soil. Each soil particle size distribution and coefficient of uniformity of experimental material obtained in the experiments were maintained in a state of the homogeneous. The specifications of the model used in this study is $160{\times}100{\times}50$(cm) of acrylic, and each soil was maintained at the height 30 cm. The water content were measured using the 5TE sensors (water contents sensors) which is installed 7 ~ 8 cm apart vertically by plugging to floor. The results of the resistivity behavior pattern for Jumunjin standard sand was found to be sensitive to the water content, while the weathered granite soil was showing lower resistivity over the time, and there was no significant change in behavior pattern observed. So, it results that the Jumunjin standard sand's particle current conduction was better than the weathered granite soil's particle through contact with the distilled water. This lab test was also compared with the result of a test bed site composed of similar weathered soil. It was confirmed that these experiments were underlying research of non-destructive investigation techniques to improve the accuracy to estimate the geotechnical parameter.

Study on electrical ageing properties of ATV silicone coatings (RTV 실리콘 코팅재의 전기적 열화 특성 연구)

  • Han, Se-Won;Cho, Han-Goo;Han, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.35-39
    • /
    • 2003
  • An ageing characteristics of RTV coating materials by corona discharge have been studied. The recovery of a hydrophobicity of RTV coating materials with the thickness of $300{\mu}m$ was in identical with a bulk silicone materials. The hydrophobicity of RTV coating materials has been almost lost when its were discharged during 40 seconds by corona with 10kV, and recovered after about 45 hours. But the resistivity of RTV coating materials has not been recovered after 45 hours, even though after 80 hours the 95% of initiation resistivity value has been recovered. There was no critical compounds(such as Si and Al) changes on RTV surfaces by the corona discharge treatment until 100 seconds. In the test of arc erosion, it was seen that the coating sample with silicone rubber as a base material have more longer bum-out time than other samples with FRP or glass base.

  • PDF

Nondestructive Damage Sensitivity for Functionalized Carbon Nanotube and Nanofiber/Epoxy Composites Using Electrical Resistance Measurement and Acoustic Emission (전기저항 측정과 음향방출을 이용한 표면 처리된 탄소 나노튜브와 나노 섬유 강화 에폭시 복합재료의 비파괴적 손상 감지능)

  • Kim, Dae-Sik;Park, Joung-Man;Kim, Tae-Wook
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.10a
    • /
    • pp.42-45
    • /
    • 2003
  • Nondestructive damage sensing and mechanical properties for acid-treated carbon nanotube (CNT) and nanofiber (CNF)/epoxy composites were investigated using electro-micromechanical technique and acoustic emission (AE). Carbon black (CB) was used to compare to CNT and CNF. The results were compared to the untreated case. The fracture of carbon fiber was detected by nondestructive acoustic emission (AE) relating to electrical resistivity under double-matrix composites test. Sensing for fiber tension was performed by electro-pullout test under uniform cyclic strain. The sensitivity for fiber damage such as fiber fracture and fiber tension was the highest for CNT/epoxy composites. Reinforcing effect of CNT obtained from apparent modulus measurement was the highest in the same content. For surface treatment case, the damage sensitivity and reinforcing effect were higher than those of the untreated case. The results obtained from sensing fiber damage were correlated with the morphological observation of nano-scale structure using FE-SEM. The information on fiber damage and matrix deformation and reinforcing effect of carbon nanocomposites could be obtained from electrical resistivity measurement as a new concept of nondestructive evaluation.

  • PDF

A Relationship between Hydraulic Conductivity and Electrical Properties of Silty Sand on the Riverside of the Nakdong River (낙동강변 실트질 모래의 수리전도도와 전기적 물성과의 관계)

  • Kim, Soo-Dong;Park, Samgyu;Hamm, Se-Yeong;Oh, Yun-Yeong
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.39-46
    • /
    • 2014
  • Hydraulic conductivity is an important parameter, representing permeable property of the groundwater in aquifers, in the issues of groundwater development, groundwater contamination, and groundwater flow, etc. We estimated a relationship between hydraulic conductivity and electrical properties (formation factor, chargeability, and time constant) of silty sand in the laboratory. For this study, we conducted grain size analysis, constant head permeameter test, and measured electrical resistivity and spectral induced polarization of silty sand samples collected from the riverside alluvium of the Nakdong River in Nogok-ri area, Dasan-myeon, Goryeong-gun in Gyeongbook Province, Korea. In the laboratory test, we used soil samples of approximately uniform porosity with 0.5% error range, and kept the electrical resistivity of pore water with 100 ohm-m. As a result, the relationship between effective particle size and hydraulic conductivity agrees fairly well with the existing empirical formulas. Hydraulic conductivity was correlated with formation factor, chargeability, and time constant: hydraulic conductivity increased with increasing formation factor and time constant as well as with decreasing chargeability.

A Validation Study on the Reinforcement Effect of Reservoir Grouting by Surface Wave Survey (표면파탐사를 이용한 저수지 제체 그라우팅 보강효과 검증 연구)

  • Bae, Hyungseop;Lee, Yeong-Dong;Won, Kyoung-Sik
    • The Journal of Engineering Geology
    • /
    • v.28 no.2
    • /
    • pp.297-312
    • /
    • 2018
  • In order to assess the safety diagnosis and grouting reinforcement effect of old reservoir facility, local governments and public offices mainly use electrical resistivity survey. However, electrical resistivity survey is a qualitative evaluation that varies the resistivity value by various exploration conditions. It is also difficult to grasp the stiffness change directly related to the stability of reservoir, thus an electrical resistivity survey is not applicable to continuous stability monitoring after grouting. The purpose of this study is to investigate and validate the quantitative evaluation of reinforcement effect of reservoir with cement grouting through shear velocity (Vs), which is closely related to the stiffness (${\mu}$) of the ground. This study was carried out on two reservoir facilities. The reinforcement effect was evaluated by comparing the permeability test, standard penetration test, down-hole test and MASW(Multi-channel Analysis of Surface wave) survey before and after cement grouting. Shear wave velocity changes before and after grouting were analyzed by phase velocity difference and inversion analysis, respectively, and the reliability of the analytical results was evaluated by comparing with field test results. Shear wave velocity increases to 5~10% in case of the D levee, and 10~20% in the levee of H reservoir. These results are showed similar pattern to the field test results.

The characteristics of leachate migration and corrosivity in municipal wastefills at seaside (해안 도시폐기물 매립지의 침출수 이동 특성 및 부식성)

  • Jang, Yeon-Su;Jeong, Ha-Ik;Kim, Jin-Man
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1992.12a
    • /
    • pp.33-66
    • /
    • 1992
  • Recently, waste landfills built on seashores have been increased because of the easy availability of broad area near the urban communities. To evaluate the performance of the marine clay landfill liner numerical contaminant transport analyses are performed by selecting the typical section of a waste landfill built on seashores and using hydraulic conductivity data obtained from the site. Also, the laboratory electrical resistivity test and the in-situ corrosion test are performed in order to analyze the influence of the soil and leachates composing the landfills on the construct ion materials. From the results of contaminant transport analyses, it is shown that the leachates can be migrated faster through narrow pervious channels than the wide homogeneous pervious tedium and the importance of good quality barriers to prevent the contaminant migration is recognized. In the laboratory electrical resistivity test all the earth materials except the cover soils saturated with distilled water have small resistivities, which shows a high potential of corrosivity of soils composing landfills. However, the degree of corrosion of specimens buried in the landfills was not so severe except the zinc and carbon steel specimens. This apparently conflict results present the necessity of the investigation of other major factors and the long term in-situ corrosion test.

  • PDF

A Study on Validation of Condition Monitering Method of Accelerated Thermal Aging CSPE (가속열화 된 CSPE 상태감시법의 유효성 연구)

  • Shin, Yong-Deok;Goo, Cheol-Soo;Kim, In-Yong;Lee, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1447-1448
    • /
    • 2011
  • The CSPE cables are used for three years in nuclear power plant. The accelerated thermal aging of chloro sulfonate polyethylene(CSPE) jacket of test cables were carried out for the period equal to 10, 20 and 30 years in air at 90 and $100^{\circ}C$, respectively. The electrical volume resistivity, density, XPS, FE-SEM, EDS and XRF of the accelerated thermal aging of CSPE were measured. The validation of condition monitering method of accelerated thermal aging CSPE was estimated by them. The best validation of condition monitoring method of accelerated aging CSPE is electrical volume resistivity because change thermal of the specimen showed distinction.

  • PDF