• Title/Summary/Keyword: electrical resistance measurement

Search Result 554, Processing Time 0.023 seconds

Optimization method of DC resistivity data acquisition system using multi-electrode arrays (다전극 배열을 사용한 DC 저항률 취득 시스템의 최적화 방법)

  • Boo, Chang-Jin;Kim, Ho-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1795-1796
    • /
    • 2006
  • The accurate measurement of soil resistivity and earthing system resistance is fundamental to electrical safety. However, geological and meterological factors can have a considerable effect on the accuracy of conventional measurements and the validity of the measurement methods. This paper presents optimization method of dc resistivity data acquisition system using multi-electrode arrays.

  • PDF

Extraction of Substrate Resistance Parameters for RF MOSFETs Based on Three-Port Measurement

  • Kang, In-Man;Shin, Hyung-Cheol
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.809-812
    • /
    • 2005
  • In this work, a new method for extracting substrate parameters of RF MOSFETs based on 3-port measurement is presented using device simulation. A T-type substrate resistance network is used. 3-port Y-parameter analyses were performed on the equivalent circuit of RF MOSFETs. All the components in the RF MOSFETs when the device is turned off were extracted directly from the 3-port device simulation data. The small-signal output admittance $Y_{22}$ can be well modeled up to 40 GHz. From the 3-port simulation and modeling results, it was verified that the proposed equivalent circuit and parameter extraction method was more accurate than the single substrate resistance model.

  • PDF

The Measurement of the Grounding Resistance Using the Ground Current of the Distribution System (접지선 전류를 시험 전류원으로 활용한 접지저항 측정기법에 관한 연구)

  • Kang, Moon-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.293-295
    • /
    • 2004
  • Public utilities adopt the grounding rules ; class I, class II, class III and special class III, and install the grounding electrodes in distribution facilities. To keep the safety of the human and the facilities, Public utilities also manage the value of ground resistance in distribution system biennially. At present the Hook-On meter is normally used to measure the ground resistance although it has ${\pm}5[%]$ measuring error and it can not measure the exact value when the current is over 1[A]. In addition it is very difficult to use the fall-of-potential method in distribution system. In this paper we propose the new measurement method using ground current of distribution system as the current source.

  • PDF

A Proposal for Construction Plan of Electric Corrosion from Measurement and Analysis for Earth Resistivity of Ha-Nam IC Water Pipe Line (하남IC 상수도관로 대지비저항 측정 및 분석에 따른 전기방식 시공방안 제시)

  • Shin, Gang-Wook;Lee, Eun-Chun;Hong, Sung-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.355-357
    • /
    • 2000
  • Measurement used electricsal sounding(MacOHM 2115, Japan) for grounding resistance of Jung-Bu highway Ha-Nam IC about 500m. To applied measurement method is fall of potential method and analysis earth resistivity used ESII(Electrical Sounding Interactive Interpretation) program. This result propose for construction plan of electric corrosion.

  • PDF

The Development of Multi-Function Measurement Module for RTD and 4-20[mA] Analog Input (RTD와 4-20[mA] 아날로그 계측용 다기능 모듈의 개발)

  • Park, Jong-Chan;Kim, Byung-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.2
    • /
    • pp.77-81
    • /
    • 2004
  • In this paper, multi-functional measurement module for RTD and 4-20mA Analog input is presented. As you know, In many industry field, RTD has been used for measuring a temperature. Although It have good properties such as wide measurement range, accuracy, the hardware or software compensation methods were applied to better linearity in many applications. According to this paper, a simply approximation method and various measuring technique are proposed to compensate large lead's resistance influence in RTD temperature measurements. As the experiment and simulation results, it is proved that the proposed method has good performance of measuring temperature. Additionally, with the CAN based communication, remote monitoring and parameter setting functions are realized.

P-Q Circle Diagram Based Parameter Measurement for Permanent Magnet Synchronous Motor Including Iron Loss

  • Urasaki, Naomitsu;Senjyu, Tomonobu;Uezato, Katsumi
    • Journal of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.55-61
    • /
    • 2003
  • This paper presents parameter measurement for permanent magnet synchronous motors based on the P-Q circle diagram. Three electrical parameters of permanent magnet synchronous motors, i.e., the equivalent iron loss resistance, armature inductance, and electrical motive force (emf) coefficient are simultaneously measured. The advantages of this method are that it can be implemented under constant excitation and it dispenses with the generating test for the emf coefficient. The proposed method is applied to a 160w permanent magnet synchronous motor, and then the measurement results are analyzed.

Electrical Properties of a Single ZnO Nanowire in a four-probe Configuration (단일 ZnO 나노선 4단자 소자의 전기적 특성)

  • Kim, Kang-hyun;Kang, Hae-yong;Yim, Chan-young;Jeon, Dae-young;Kim, Hye-young;Kim, Gyu-Tae;Lee, Jong-Soo;Kang, Woun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.12
    • /
    • pp.1087-1091
    • /
    • 2005
  • Four-probe device of single ZnO nanowire was fabricated by electron beam lithography. Electrical characterizations in a two-probe and a four-probe configuration with a back-gate were carried out to clarify the relative contribution of the contact and the intrinsic part in a ZnO nanowire. I-V characteristic in four-probe measurement showed an ohmic behavior with a high conductivity, 100 S/cm, which was better than those of two-probe measurement by 10 times. At the same values of the current between two-probe and four-probe, the net voltage applied inside the nanowire were extracted with calculated voltages at the contact. Four-probe current-gate voltage characteristics showed bigger tendencies than those of two-probe measurement at low temperatures, indicating the reduced gate dependence in two-Probe measurements by the existence of the contact resistance.

Efficiency Estimation of Toxicity Free Eire Resistance Cable

  • Yoon, Hun-Ju;Hon, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.3
    • /
    • pp.34-38
    • /
    • 2002
  • In this paper, efficiency estimation of toxicity fee fire resistance cable experiments was measured smoke density of toxicity free fire resistance polyolefin insulation material and electric field dependence of tree shape in low density polyethylene (LDPE). One of the most serious causes of failure in high-voltage cables, can be an electrical discharge across an internal gab or void in the insulating material. Treeing due to partial discharge is one of the main causes of breakdown in the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation and research of the fire resistance character has become important. First, we have studied on electric field dependence of tree shape in LDPE about treeing phenomena occurring on the high electrical field. Second, the measurement method is the attenuation quantity of irradiation by smoke accumulating with in a closed chamber due to non-flaming heat decomposition and flaming combustion. A main cause of fire-growth and generating toxic gas when, it bums, should be dealt with great care in life. safety design. The fire gases were occurred carbon monoxide and decomposition than in polyolefin due to incomplete combustion of PVC, which has high content of carbon in chemical compound.

Electrical Impedance Response Model of Concrete in Setting Process (응결 과정 콘크리트의 전기 임피던스 응답 해석 모델)

  • Shin, Sung Woo;Hwang, Garam;Lee, Chang Joon
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.116-122
    • /
    • 2014
  • Assessment of setting process of concrete is important as it provides useful information to schedule concreting work in construction site. Electrical impedance measurement method, which utilizes the change of electrical resistance of concrete, has been applied to assess setting process of cement-based materials. However, the applicability of the method has been demonstrated only for cement paste and mortar. The main purpose of this research is to develop the electrical impedance based setting process assessment for concrete. To this end, electrical impedance response model for concrete should be developed in advance since it is essential to estimate the electrical resistance of concrete from measured impedance response. The electrical resistance of concrete is a key parameter for the setting process assessment. In this study electrical impedance responses of the concrete in setting process are measured and analyzed. Thereby, an electrical impedance response model of the liquid state concrete is developed and schematically validated.

Identification of Electrical Resistance of Fresh State Concrete for Nondestructive Setting Process Monitoring

  • Shin, Sung Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.6
    • /
    • pp.414-420
    • /
    • 2015
  • Concrete undergoes significant phase changes from liquid to solid states as hydration progresses. These phase changes are known as the setting process. A liquid state concrete is electrically conductive because of the presence of water and ions. However, since the conductive elements in the liquid state of concrete are consumed to produce non-conductive hydration products, the electrical conductivity of hydrating concrete decreases during the setting process. Therefore, the electrical properties of hydrating concrete can be used to monitor the setting process of concrete. In this study, a parameter identification method to estimate electrical parameters such as ohmic resistance of concrete is proposed. The effectiveness of the proposed method for monitoring the setting process of concrete is experimentally validated.