• 제목/요약/키워드: electrical insulation

검색결과 2,078건 처리시간 0.029초

저밀도 폴리에틸렌에 있어서 부분방전과 음향방출펼스 상호간의 회기분석에 의한 신뢰도 평가 (A Reliability Evaluation by Regression Analysis of PD and AE Pulse in Low Density Polyethylene)

  • 김성홍;최재관;윤헌주;심종탁;김재환;박재준;신승중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1761-1763
    • /
    • 1997
  • Because of internal voids in insulators give rise to partial discharge (PD), which cause local breakdown and even entire insulation breakdown. Treeing due to PD is one of the main causes of breakdown of the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation has become important. From this viewpoint, our studies diagnose insulation degradation using the method of computer sensing system, which has the advantages of PD and acoustic emission (AE) sensing system. To use advantages of these two methods can be used effectively to search for treeing location and PD in some materials. In analysis method of degradation, We analyzed the PD pulse and AE pulses by regression analysis, compared to these obtained the correlation coefficient and determination coefficient by T-distribution and saw that PD and AE pulses show a similar pattern on the whole. This is in agreement with the results of the research by Yoshimura and Fujita.

  • PDF

초전도 변압기의 절연기반 연구 (A Study on the Insulation Basis of Hts Transformer)

  • 천현권;곽동순;윤문수;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.639-642
    • /
    • 2005
  • HTS Transformer developing is developing a power distribution and transmission class HTS transformer that is one of the 21st century superconducting frontier projects. Therefore, we prepared the model, that is Z continuous winding from Kapton insulated Cu tape for a small simulated the HTS transformer. For the development of electrical insulation design of a HTS transformer with Z continuous winding, we have been discussed insulation composition and investigated breakdown characteristics such as breakdown of liquid $N_2(LN_2)$, polymer and surface flashover on FRP and breakdown-surface combination in $LN_2$. Also we have been designed and manufactured a bobbin that has spiral slot for the Z continuous winding. The Z continuous winding mini-model from Kapton film insulated Cu tape for simulated 22.9kV class HTS transformer has been constructed using 0.1 % breakdown strength obtained by Weibull distribution. The widing model was measured their insulation characteristics such as ac (50kV, 1min) and impulse (154kV, $1.2\times50{\mu}s$ full wave, 3 times) withstand test and its excellent performance was confirmed.

  • PDF

동적 시정수 기반 고성능 절연 저항 계산 기법 (Dynamic Time Constant Based High-Performance Insulation Resistance Calculation Method)

  • 손기범;홍종필
    • 한국정보통신학회논문지
    • /
    • 제24권8호
    • /
    • pp.1058-1063
    • /
    • 2020
  • 본 논문에서는 IT 접지 시스템의 감전 및 화재사고 방지를 위한 새로운 절연 저항 계산 기법을 소개한다. 최근 신재생 에너지와 에너지 저장 장치의 확대 보급으로 태양광 발전 시장이 급속하게 성장하고 있으나 절연이 파괴되어 화재사고가 빈번히 발생함에 따라 IT 접지 방식에도 절연 저항 상태를 감시하는 장치가 필수적으로 요구되고 있다. 제안하는 절연 저항 계산 기법은 기존의 고정된 시정수곱 계수기반의 알고리즘에 비해 절연 임피던스의 조건에 따라 동적시정수곱계수를 적용함으로써 넓은 절연 저항 범위에서 빠른 응답 시간과 높은 정확도를 갖는다. 제안하는 동적 시정수 기반 절연 저항 계산 기법은 기존의 방법에 비해 최대 응답 시간은 39.29초, 오차율은 20.11%를 개선시키는 효과를 보였다.

프레스 보드의 제작과 특성 평가(I) (Characteristics and Fabrication of Pressboard( I ))

  • 김귀열;엄승욱;강동필;윤문수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1993년도 추계학술대회 논문집
    • /
    • pp.67-70
    • /
    • 1993
  • A pressboard providing both good insulation and mechanical properties is required as for insulating material in oi1-immersed transformers insulation. This study has examined fabricating methods and specimen characteristics of pressboard.

  • PDF

배전용 전력케이블의 반도전층에 함유되어 있는 불순물 분석 (Impurities of the Semiconductive Shield in the Power Distribution Cable)

  • 김상준;송일근;김주용;한재흥;서광석;이창용;이창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1794-1796
    • /
    • 1996
  • In order to evaluate the soundness of 10 year service-aged XLPE-insulated 22.9 kV underground distribution cables, semiconductive shields have been characterized. The edge of insulation near the insulation shield shows a drastic decrease of OIT. Impurities such as Ca, Mg, Fe, Cu were detected in both conductor and insulation shields. Their concentrations at the insulation shield are much higher than those at the strand shield. All these facts suggest that the edge of insulation near the insulation shield is degraded considerably, which might be attributed to the oxidation reaction of insulation by a large amount of impurities in the insulation shield.

  • PDF

염수에 의해 열화된 절연커버 및 옥외용 가교폴리에틸렌 절연전선의 표면구조변화 (A Change of Surface Structure with Insulation Cover and Outdoor Cross-linked Polyethylene Insulated Wire Degraded by Salt Water)

  • 최충석;길형준;김향곤;한운기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1897-1899
    • /
    • 2004
  • In this paper, in order to analyze the characteristics of degradation by salt water with insulation cover and OC wire(outdoor cross-linked polyethylene insulated wire) used in power receiving system, an experimental apparatus has been designed and fabricated. An insulation cover and OC wire were installed in an experimental apparatus, and degraded in each case of 2%, 5%, 10% salinity during 12 weeks. An optical microscope was used to observe a changing process of sample surface, and an electrical safety was analyzed by measuring dielectric breakdown voltages of samples. As salinity increased, so ununiformity of sample surface increased. The breakdown wasn't produced to 50kV about samples regardless of salinity, testing period.

  • PDF

전기기기용 비닐절연전선에서의 직렬 아크에 의한 열화 특성 분석 (Analysis of Deterioration Characteristics of Polyvinyl Chloride Insulation Wires for Electrical Apparatus by Series Arcing)

  • 김향곤;길형준;김동욱;김동우;최충석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.234-235
    • /
    • 2006
  • In this study, we experimented deterioration characteristics of PVC insulation wires for electrical apparatus by series arcing and analyzed the heat generation at the contacts of wires, glowing/growing process of copper oxide, waveforms of contact voltage, current, power dissipation, and so on. We found out that how glowing contacts and surface arcing can decompose PVC insulation and that subsequent series arc can lead to ignition. We expect that these results are useful for improving fire protection technology by providing a better understanding of how electrical fires can initiate.

  • PDF

전기 절연성능 향상을 위한 폴리머 애자의 표면 특성 연구 (A Study on the Surface Properties of Polymer Insulators for Improving Electrical Insulation Performance)

  • 박용섭;배재성;홍병유;이재형
    • 한국전기전자재료학회논문지
    • /
    • 제34권1호
    • /
    • pp.63-67
    • /
    • 2021
  • In this paper, we investigated the surface properties of polymer insulators to improve electrical insulation performance. First, after washing the polymer insulator in various ways, its contact angle was increased, thereby improving the hydrophobic properties and electrical insulation properties. In addition, TiO2 thin films, which have been used as a photocatalytic material and have been applied to the polymer insulator surface of to enhance the surface and electrical insulating properties. For the sputtering method, the contact angle after coating the TiO2 thin film increased with increasing RF power, but it was lower compared to that before coating, indicating that the hydrophobic properties of the surface were slightly deteriorated. Consequently, the electrical properties of the polymer-insulating material were maintained or improved after the TiO2 thin-film coating.

Analysis of Insulation Quality in Large Generator Stator Windings

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho;Kim, Byong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권3호
    • /
    • pp.384-390
    • /
    • 2011
  • To evaluate the condition of stator winding insulation in generators that have been operated for a long period of time, diagnostic tests were performed on the stator bars of a 500 MW, 22 kV generator under accelerated thermal and electrical aging procedures. The tests included measurements of AC current (${\Delta}I$), dissipation factor ($tan{\delta}$), partial discharge (PD) magnitude, and capacitance (C). In addition, the AC current test was performed on the stator winding of a 350 MW, 24 kV generator under operation to confirm insulation deterioration. The values of ${\Delta}I$, ${\Delta}tan{\delta}$, and PD magnitude in one stator bar indicated serious insulation deterioration. In another stator bar, the ${\Delta}I$ measurements showed that the insulation was in good condition, whereas the values of ${\Delta}tan{\delta}$ and PD magnitude indicated an incipient stage of insulation deterioration. Measurements of ${\Delta}I$ and PD magnitude in all three phases (A, B, C) of the remaining generator stator windings showed that they were in good condition, although the ${\Delta}tan{\delta}$ measurements suggested that the condition of the insulation should be monitored carefully. Overall analysis of the results suggested that the generator stator windings were in good condition. The patterns of PD magnitude in all three phases (A, B, C) were attributed to internal discharge.

온도, 습도의 누설전류와 절연저항 영향 연구 (Study on Leakage Current and Insulation Resistance Effect of Temperature and Humidity)

  • 한경철;최용성
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.370-374
    • /
    • 2019
  • 본 논문에서는 전기재해를 일으킬 수 있는 요소를 미리 제거하기 위해 보다 효율적이고 신뢰성 있는 누설전류 검출방법을 찾고자 온도, 습도가 다른 환경에서 누설전류 및 절연저항을 측정하여 그 측정값에 대한 차이점을 비교하고 분석하였다. 식당과 상점에서 누설전류 및 절연저항을 비교한 결과 식당에서 누설전류와 절연저항은 모두 허용값을 만족하였지만 2개 회로는 누설전류가 높게 나타났을 때 절연저항도 높게 나타나는 비정상적인 비례관계를 나타내었다. 상점에서 누설전류와 절연저항은 1개 회로에서 누설전류가 허용값 이하로 부적합하였지만 절연저항은 모두 허용값을 만족하였다. 누설전류 및 절연저항이 허용값 이내일 때도 비정상적인 비례관계를 나타냈으며 이러한 부하는 대부분 전열부하로 분석되었다.