A Reliability Evaluation by Regression Analysis of PD and AE Pulse in Low Density Polyethylene

저밀도 폴리에틸렌에 있어서 부분방전과 음향방출펼스 상호간의 회기분석에 의한 신뢰도 평가

  • Kim, S.H. (Department of Electrical Engineering, Kwangwoon University) ;
  • Choi, J.K. (Department of Electrical Engineering, Kwangwoon University) ;
  • Yoon, H.J. (Department of Electrical Engineering, Kwangwoon University) ;
  • Shim, J.T. (Department of Electrical Engineering, Kwangwoon University) ;
  • Kim, J.H. (Department of Electrical Engineering, Kwangwoon University) ;
  • Park, J.J. (Department of computer Science, Joong Bu University) ;
  • Shin, S.J. (Department of computer Science, Joong Bu University)
  • Published : 1997.07.21

Abstract

Because of internal voids in insulators give rise to partial discharge (PD), which cause local breakdown and even entire insulation breakdown. Treeing due to PD is one of the main causes of breakdown of the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation has become important. From this viewpoint, our studies diagnose insulation degradation using the method of computer sensing system, which has the advantages of PD and acoustic emission (AE) sensing system. To use advantages of these two methods can be used effectively to search for treeing location and PD in some materials. In analysis method of degradation, We analyzed the PD pulse and AE pulses by regression analysis, compared to these obtained the correlation coefficient and determination coefficient by T-distribution and saw that PD and AE pulses show a similar pattern on the whole. This is in agreement with the results of the research by Yoshimura and Fujita.

Keywords