• Title/Summary/Keyword: electrical grid

Search Result 2,230, Processing Time 0.038 seconds

Probabilistic Reliability Evaluation of Power System using TRELSS II - Focused on Case Studies of IEEE RTS - (TRELSS를 이용한 전력계통의 확률론적 신뢰도 평가 II - IEEE RTS 사례연구를 중심으로 -)

  • Tran, Tungtinh;Kang, Sung-Rok;Choi, Jae-Sok;Jeon, Dong-Hoon;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.67-70
    • /
    • 2003
  • In recent, the importance and necessity of some studies on reliability evaluation of grid come from the recent black-out accidents occurred in the world. The quantity evaluation of transmission system reliability is very important under competitive electricity environment. The reason is that the successful operation of electric power under the deregulated electricity market depends on transmission system reliability management. The various results of many case studies for the IEEE 25buses system using the Transmission Reliability Evaluation for Large-Scale Systems(TRELSS) Version 5_1, a program made in EPRI are introduced in this paper. Some sensitivity analysis has been included. This paper suggests that the some important input parameters of the TRELSS can be determined optimally from this sensitivity analysis for high reliability level operation of a system.

  • PDF

Assessment of the Protection Algorithm Applied in Distributed Generations for Faults Occurred in the Interconnected Distribution Networks (외부 배전선 사고에 대한 분산전원 보호 알고리즘의 동작 수준 평가)

  • Jang, S.I.;Kim, S.G.;Park, Y.U.;Kim, K.H.;Choi, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.337-340
    • /
    • 2003
  • This paper describes the operational characteristics of protection algorithm applied in distributed generations(DG) for faults occurred in the interconnected distribution networks. The DG can be Influenced by abnormal grid conditions such as disturbances occurring in the neighboring distribution feeders as well as the interconnected power line. Particularly, in case of the fault happening in the neighboring distribution feeders emanated from the substation to which DG is connected, the protective devices in the DG might mis-operate. The mis-operation of protective devices can be varied by the fault conditions. The simulation results for Hoenggye substation model composed of five feeders using PSCAD/EMTDC showed that the number of mis-operation of protective devices applied in DG is about 0.66 times per one year.

  • PDF

Characteristic Analysis of Multi-grounding System by Using a Scale Model Technique (축소모델기법을 이용한 다중접지계의 특성분석)

  • Lee, J.B.;Myung, S.H.;Chang, S.H.;Cho, Y.G.;Kim, J.S.;Kil, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1738-1740
    • /
    • 2003
  • This paper deals with the characteristic analysis of multi-grounding system. In order to assess the effectiveness of bonding two grounding systems, the scale model grounding simulation system and grid grounding conductors which were downsized as a scale factor of 100:1 were designed and fabricated. A profile of GPR(Grounding Potential Rise) of each case was measured. Also the measured results were compared with the analysis results.

  • PDF

The Analysis of Power Quality for the Synchro/Asynchro Generation System in Dae kwan Ryung Actual Wind Farm (대관령 풍력실증단지의 동기/유도발전기 전력품질 분석)

  • Kim, Hyun-Han;Jeong, Jong-Chan;Ki, Woo-Bong;Lee, Kue-Sam;Kim, Kwang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.770-771
    • /
    • 2007
  • Wind power plant is based on the wind energy so the active power is frequently changed and connected to grid according with wind condition. These characteristics are bed effect to distribution line. On this reserch, we want to analyze the quality of electric power synchro/asynchronous generation system in Dae Kwan Ryung wind farm. The contents of analysis are active/reactive power variation and total demand distortion and transiency and sag/swell phenomena. we hope this research can contribute to the power quality improvement.

  • PDF

Practical Implementation of an Interleaved Boost Converter for Electric Vehicle Applications

  • Wen, Huiqing;Su, Bin
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.1035-1046
    • /
    • 2015
  • This study presents a practical implementation of a multi-mode two-phase interleaved boost converter for fuel cell electric vehicle application. The main operating modes, which include two continuous conducting modes and four discontinuous conducting modes, are discussed. The boundaries and transitions among these modes are analyzed with consideration of the inductor parasitic resistance. The safe operational area is analyzed through a comparison of the different operating modes. The output voltage and power characteristics with open-loop or closed-loop operation are also discussed. Key performance parameters, including the DC voltage gain, input ripple current, output ripple voltage, and switch stresses, are presented and supported by simulation and experimental results.

Improved Transient Response of Distributed Energy Resources Inverters to PQ Control using Decoupling (분산전원용 인버터의 유효 무효전력 감결합을 통한 PQ제어 과도상태 특성개선)

  • Choi, Chul-Hoon;Choi, Jong-Woo;Lee, Chang-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.438-444
    • /
    • 2012
  • This paper deals with the active and reactive power control of Grid connected system. It was shown that active power and reactive power can be dependently controlled with two individually adaptable parameters. The two parameters are power angle and voltage magnitude. Transient state will occur with active or reactive power reference value variation. This paper presents a new control strategy for active and reactive power control of less interaction and improved transient response. The paper details the control technique by the mathematical and electrical network analysis of the methodology. The performance was verified through computer simulation using MATLAB Simulink and experiment.

Design of 100kW Grid connected Inverter system for Fuel Cell Voltage characteristics (연료전지 전압 특성을 고려한 100kW 계통 연계 인버터 설계)

  • Jang, Ju-Young;Joung, Woo-Taek;Moon, Sang-Ho;Lee, Jeong-Hum;Son, Yong-Hun;Kim, Min-Kyu
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.142-143
    • /
    • 2012
  • EBOP(Electrical Balance of Plant)는 연료전지 출력인 DC 전원을 전력변환기술을 이용하여 계통 전원에 연계하는 계통 연계형 PCU 시스템이다. EBOP는 연료전지의 DC 전압 특성을 고려하여 인버터를 설계하여야 안정적인 전력 제어가 가능하다.

  • PDF

Operational Characteristics of Grid-Interactive Distributed Generation System with Voltage-controlled VSI (전압제어형 VSI를 적용한 계통연계형 분산전원시스템의 동작특성)

  • Kang, Dae-Up;Cho, Sung-Phil;Ko, Sung-Hun;Lee, Seong-Ryong;Lee, Su-Won;Mun, Young-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1151-1152
    • /
    • 2007
  • 본 논문에서는 전력품질개선, 부하수요관리, 무정전전원공급, 부하전압안정화 등의 기능을 통합적으로 수행할 수 있는 전압제어형 전압원인버터(VCVSI: Voltage-Controlled Voltage Source Inverter)를 적용한 계통연계형 분산전원시스템의 제어 알고리즘을 제안하였다. 제안 된 시스템은 계통, 신재생에너지원(또는 배터리) 그리고 부하조건에 따라 3가지 모드(전력품질개선모드. 부하수요관리모드, 무정전전원공급모드)에 따라 동작한다. 본 연구에서는 각각의 모드에 따른 동작특성을 분석하고, 시뮬레이션을 통해 그 유용성을 확인하였다.

  • PDF

A Study about Grid-Connected Wind Power Generation System (계통연계 풍력발전 시스템에 관한 연구)

  • Cho, Moon-Taek;Hwang, Lak-Hun;Kim, Young-Soo;Na, Seung-Kwon;Song, Ho-Bin;Kim, Yeal-Chung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1238-1240
    • /
    • 2007
  • The wind force development system is applying variableness inside system recently. High-capacity system performs blade pitch check and main point check, but because pitch angle is fixed in case of capacity system, development efficiency drops. Must do to achieve variableness inside control about change of manners to be acted in maximum electric power point hereupon. Treatise that see hereupon proves this theoretically, and proved validity through 400 [W] experiments.

  • PDF

A localization method using sensor fusion system (다중 센서 시스템을 이용한 로봇 위치 인식 제어 방법)

  • Lim, Jea-Gyun;You, Jong-Jin;Hyun, Woong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1767-1768
    • /
    • 2007
  • This paper represents a map building system of Embedded Linux mobile robot. We propose a localization method which uses multiple sensors such as indoor GPS and encoder sensor for simultaneous map building system. In this paper we proposed a multiple sensor system for SLAM. For this, we developed a sensor based navigation algorithm and grid based map building algorithm under the Embedded Linux O.S. We proved this system's validity through field test

  • PDF