• Title/Summary/Keyword: electrical disaster

Search Result 284, Processing Time 0.031 seconds

A Electrical Fire Disaster Prevention Device of High Speed and High Precision by using Semiconductor Switching Devices (반도체 스위칭 소자를 이용한 고속 고정밀의 전기화재 방재장치)

  • Kwak, Dong-Kurl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.423-430
    • /
    • 2009
  • Recently as the inactive response characteristics of the existing RCD used on low voltage power distribution system, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore, this paper confirms the unreliability of the existing RCD by electrical fault simulator and proposes a EFDPD by using semiconductor switching devices and a high precision current sensor (namely, reed switch) for the prevention of electrical disasters in low voltage power distribution system caused by overload or electric short circuit faults. The sensitive reed switch in the proposed EFDPD exactly detects the increased magnetic flux with the overload or the short current caused by a number of electrical faults, and the following, the self circuit breaker in EFDPD rapidly cuts off the system. The proposed EFDPD confirms the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker through various operation performance analysis. The proposed EFDPD can also prevent electrical disasters, like as electrical fires, which resulted from the malfunction and inactive response characteristics of the existing RCD.

A Study on the Actual Condition Analysis and Improvement Direction of Disaster Safety Education Training Course in School - Focused on Disaster Safety Management for School Facilities - (학교 재난안전 교육연수과정 실태분석 및 개선방향에 관한 연구 - 학교시설에 대한 재난안전관리 중심으로 -)

  • Lee, Byoung-Ho;Park, Youn-Ju;Lee, Jae-Rim
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.17 no.2
    • /
    • pp.11-21
    • /
    • 2018
  • This study suggests desirable disaster safety education curriculum through analyzing the operational status of the school disaster safety management training course and demand survey of school staff. First, the problem of the disaster safety training course of the school is not connected with the lack of law and system and the school disaster safety job. Second, improvement of law and system and variety of training should be made to acquire professional knowledge. Third, it is necessary to divide curriculum into the following four categories, according to educational needs of public officials ; Educational administration officers course focused on facility safety, maintenance and disaster countermeasure. Educational officials in technical post course addressing approval and permission of school facility projects, seismic reinforcement of school building, etc. Educational supervisors course covering roles and responsibilities of the school safety supervisors in the event of disaster. Teaching staffs course focused on safety instructions for students. Fourth, it is found that lectures and experiential learning methods are the most desirable methods of teaching and learning, and the major ranks are earthquake disaster, fire, gas, typhoon, school road, and electrical safety.

A Study on the Properties Analysis and Estimation of Odor Detection System (향 검지 시스템의 특성 해석 및 평가에 관한 연구)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.1-5
    • /
    • 2009
  • We studies wish to investigated establishment form of cabinet board, and confirm possibility of electrical disaster prevention through reappearance experiment of odor detection system. Established breaker consists of MCCB, RCD order in cabinet board for house, but industry is used together with. When imposed shock using shaker to terminal block that contact becomes in appropriate, flame was made sure. According to result that experiment attaching odor capsule in terminal block, capsule commissioned exactly by occurred heat. According to establishment position of sensor, difference of inspection time was about 10 seconds. Estimate odor inspection system by thing which electrical device accident prevention is available. When there is abnormal generated heat in connection of electric wire, accident prevention estimates that is possible by giving an alarm state of overheat to administrator.

Free Vascularized Scapular and Parascapular Combined Flap Coverage for Extensive Soft Tissue Injury of the Extremity (견갑 및 부견갑 병합 유리피판에 의한 광범위한 사지 연부 조직 결손의 수복)

  • Choi, Soo-Joong;Chang, Kee-Young;Lee, Chang-Ju
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.2
    • /
    • pp.144-151
    • /
    • 2005
  • Purpose: Disaster as traffic accident, industrial disaster, high voltage electrical bum and flame burn of extremity have a destructive effect because of the involvement of deep structure. Generally, such injury may result in decreased function or loss of limb. In this study the successful use of the combined scapular/parascapular flap as microsurgical transfer to cover extensive defect of electrical and flame bum is reported. Material and Method: Between January 2000 and June 2001, the combined scapular and parascapular flap was used for the coverage of soft tissue defect for 7 patients were admitted to our department with high voltage electrical bum and flame burn. The recipient site were the wrist joint in 2 cases, the forearm in 1 case, the ankle joint in 1 case, the foot dorsum in 1 case, the heel in 1 case. Result: Flap survival was complete in all patients. The result of flap coverage for these deep wound was successful. Conclusion: The advantages of scapular/parascapular combined flap were coverage of the large defect, easy shaping of the flap to fit the required three dimensional configuration around the joint, non hair bearing skin of uniform thickness, minimal donor site morbidity.

  • PDF

The Study on the Optimal Operating Conditions of Direct Charging Type Electrospray for Particulate Matter Collection (미세먼지 집진을 위한 직접 하전 방식 정전분무의 최적 동작 조건에 관한 연구)

  • Sugi Choi;Sunghwan Kim;Haiyoung Jung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.5
    • /
    • pp.474-481
    • /
    • 2023
  • This paper is an experimental study on the optimal operating conditions of direct charging type electrospray for particulate matter collection. To perform the research, a direct charging type electrospray visualization system was configured to photograph the spray shape of microdroplets, and experiments were performed with varying electrode distance, flow rate, and applied voltage, which are the main factors affecting the particulate matter collection efficacy. Through image processing, the total number of microdroplets according to each condition was analyzed, and the number of microdroplets with a diameter of 1.5 mm or less was confirmed. In addition, by calculating the number of microdroplets per power consumption according to the applied voltage, the optimal operating conditions were derived in terms of energy consumption efficacy, and the microdroplet size distribution was analyzed under the optimal operating conditions. As a result of the experiment, it was confirmed that the optimal operating condition was at a flow rate of 10 mL/min and a voltage of -20 kV in case of 5 mm electrode distance, and at a flow rate of 15 mL/min and a voltage of -30 kV in case of 100 mm electrode distance.

A Study on the Analysis of Fire Mechanisms in Electronic Products due to Failure and Malfunction of Thermostats Through Fire Cases and Reproduction Experiments (화재사례 및 재현실험을 통한 온도조절장치 고장 및 오동작으로 인한 전자제품 화재 메커니즘 분석)

  • Jeong-il Lee;Jong-Hwa Im
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.1
    • /
    • pp.31-38
    • /
    • 2024
  • In this paper, as there are many cases of fires occurring due to the failure or inoperability of the thermostat of electronic products, the purpose is to test and analyze the risks and probabilities through fire cases and reproduction experiments, and suggest countermeasures. Among electronic products, water purifiers are composed of a refrigerant system with a compressor to make cold water, a heating device to make hot water, and an electric device used as an energy source. Due to the nature of the water purifier manufacturing, these devices are subject to a lot of moisture and dust. etc. exist in large quantities and use electrical energy, so there is a possibility of fire due to short circuit in the wire, electrical abnormal overheating (tracking phenomenon) in the thermostat, electronic board, starting relay, etc., and overheating of the heating device (Band Heater). there is. Therefore, in order to prevent fires from these devices, a system to remove foreign substances inside the water purifier is necessary, the use of heat-resistant (fire-resistant) wires for electrical devices is essential, and the use of non-combustible materials (semi-combustible materials) for each part is necessary to prevent fire. The risk must be eliminated through prevention and combustion expansion prevention devices.

Analysis of Earthquake Countermeasure for Electrical Facility Building on Domestic and Foreign (국내외 건축물에 시설되는 수변전설비 지진 대책에 관한 조사 분석)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.150-156
    • /
    • 2008
  • Recently life and properties damage at Japan and China by generating earthquake. For establishing measure for earthquake in domestic, earthquake disaster measure law was enacted on March, 2008 from a natural disaster of earthquake and present the detail part and enforce the measures. This paper analyzes domestic site and problems of electrical facility earthquake measures at transformer vault which the power supply the emergence situation at generating earthquake. Also we present the domestic seismic design and construction direction from research and analysis related law and regulation for the seismic design and construction in domestic and foreign for electrical facility. Afterward we will need to study reliability inspection for electrical facility seismic design method and construction at buildings transformer vault.

A Study on the Development of Value-Added Service Based on Remote Electrical Safety Inspection of Electrical Facilities for Private User (일반용 전기설비의 원격 전기안전점검 모델을 활용한 전기안전 부가서비스 제공 방안에 관한 연구)

  • Choi, Myeong-Il;Yoo, Jae-Geun;Jeon, Jeong-Chay;Jung, Yong-Uk
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.365-368
    • /
    • 2008
  • This paper introduce the model of remote monitoring system that combine information technology in electrical safety checks that has been done by professional staff. And for general use, electrical safety Value-Added Service using remote check data were presented. In the near future, If demand and interests of Value-Added Service will be increased, this will be a electrical safety Value-Added Service as an important role in the blind spot of country electricity disaster.

  • PDF

The Accident Analysis Caused by Dust of Electrical Installation in Vulnerable Area (전기설비 취약지역에서의 분진에 의한 사고영향 분석)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Jong-Min
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.345-348
    • /
    • 2008
  • In this paper, we investigated a dust pollution and spot survey of electrical installation in vulnerable area. From the survey results, we know that the dust was easily accumulated in cabinet panel because the cabinet panel cover was opened and the management of installation was not good. Although the dust pollution was not difference, the possibility of accident become increased by dust in salt area. Thus, it is necessary to variation of cabinet panel shape to prevention of electrical disaster in dust occurrence and another protection devices.

  • PDF