• Title/Summary/Keyword: electric work

Search Result 1,035, Processing Time 0.028 seconds

The Effect of the Anode Thickness on Electrolyte Supported SOFCs

  • So Yeon Shin;Dae-Kwang Lim;Taehee Lee;Sang-Yun Jeon
    • Journal of Electrochemical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.145-151
    • /
    • 2023
  • Planer-type electrolyte substrates are often utilized for stack manufacturing of electrolyte-supported solid oxide fuel cells (ES-SOFCs) to fulfill necessary requirements such as a high mechanical strength and redox stability. This work did an electrochemical analysis of ES-SOFC with different NiO-YSZ anode thicknesses to find the optimal value for the high performance of the fuel cell. The cell resistivities were constant at anode thickness between 25-58 ㎛, but a thick anode (74 ㎛) caused a high electrode resistivity leading to a dramatic reduction in cell performance. A stability test was performed for 50 hours at 700℃, and the results showed a degradation rate of 0.3% per 1000 h by extrapolated fitting.

EPD Thick Film Formation of Ceramic Powder Materials (세라믹 분말재료의 EPD 후막형성 기술)

  • Soh, Dea-Wha;Jeon, Yong-Woo
    • Journal of the Speleological Society of Korea
    • /
    • no.75
    • /
    • pp.49-54
    • /
    • 2006
  • Electrophoretic Deposition (EPD) is the most convenient technology to deposit natural or oxide powders of nonconductive materials in alcoholic suspension solution with adding electrolyte of iodine to form ceramic thick film on metal substrate under applied electric field with double electric layer between electrode and metal substrate. In this research work, the important parameters and technical ways were studied to form EPD thick films of typical oxide ceramics of Al2O3, YBCO and tourmaline powders.

Looseness Estimation of Bolts on Truss Structure with PZT Patches

  • Jiang, Zhongwei;Akeuchi, Yasutaka
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.86.6-86
    • /
    • 2002
  • This work presents a study on development of a practical and quantitative technique for assessment of the healthy state of a structure by piezoelectric impedance-based technique associated with longitudinal wave propagation measuring method. A truss structure embedded with piezoelectric patches is investigated for a fundamental study on estimation of the looseness of bolts in the joint. In order to evaluate the minute mechanical impedance change due to loosening bolt, a harmonic longitudinal elastic wave is applied to the structure by a pair of PZT patches and their electric impedance is measured simultaneously. According to the experimental results, the change of the electric impedance of P...

  • PDF

EIC integrated DCS with single console

  • Kawahara, Hiroshi;Hwa, Hong-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.928-933
    • /
    • 1988
  • Control technology has been making remarkable progress in electrical control (E), instrumentation & control (I) and computer control (C) field respectively. In order to rationalize system engineering and simplify system configuration and operation work, so called, EIC are now to be integrated into one system. FUJI has developed it's own E, I&C integrated system, to meet above mentioned market requirements of variety. This paper describes basic concept of FUJI's Integrated Man-Machine Interface, hereinafter called SINGLE CONSOLE, from some view points of E, I, C integration technology.

  • PDF

Laser Diagnostic in a Plasma Display Panel Discharge Cell

  • Choi, Young-Wook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.21-22
    • /
    • 2000
  • Laser diagnostic method in a plasma display discharge cell was introduced. The information of electric field, potential and electron temperature et al. in the surface of plasma display panel can be measured using laser induced fluorescence spectroscopy. However, because of the very small discharge dimension of ${\sim}$ 100 ${\mu}m$, the measurement attempt has almost not been performed. In this paper, the direct measurement possibility of the parameters and the recent work of electric field measurement are demonstrated in the plasma display panel.

  • PDF

A SERME Control in the Hydraulic or Electric Type Drive Application

  • Ahn, T.Y.;Lee, D.O.;Kim, H.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.455-459
    • /
    • 1994
  • One relay control implementation to the servo control systepm is contrlved mainly for the high power electric or electro hydraulic type drive system. Proposed SERME control is relay emulated software scheme accounting a reay producing maximum torque in both direction in the insufficient bandwidth control system. Possibillty is proposed mathematically prlor to emperical work out.

  • PDF

A Study on Effective Floor Area for Wheelchair Users to Use Toilet (휠체어 사용자의 대변기 이용을 위한 화장실 유효바닥면적에 대한 연구)

  • Ryu, Sang-oh;Kim, Bo-hee;Park, Ji-young
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.24 no.2
    • /
    • pp.79-87
    • /
    • 2018
  • Purpose: The purpose of this paper is to provide logical basis on enlargement of toilet floor space for the disabled by "ACT ON GUARANTEE OF PROMOTION OF CONVENIENCE OF PERSONS WITH DISABILITIES, THE AGED, PREGNANT WOMEN. ETC" Revised Enforcement regulation [Asterisk 1] (2018.2.10.) and to help with making plans, designs and establishing policies by conducting experimental study with the enhanced floor area regulations. Methods: We conduct Experimental study, field work and interview for this paper. In experimental study, verification of the effective floor area was proceeded by measuring activity space for people in manual wheelchair, electric wheel chair and electric scooter and also reviewed useable area with the space expanded 0.2m both width and depth. In filed work, conducted an observation what other things (ex. sanitary equipment, hand rail and so on) can also affect the active space as well as effective floor space. In the interview, other problems and requirements that were not revealed were experimental study and observation of field work. Results : it's expected to provide better access to toilets for the disabled with the law revision of effective floor area. But, with the usage increasement of enlarged wheel chair and electric wheel chair, expanding side areas of toilet is also highly likely to be required going forward. Implications : Additional research is required on locations of exists and internal arrangement that effect the usage of toilet. It should be led to Universal design by making additional investigation and verification of the users patterns.

Moment Resisting Behaviors of Railway Electric Pole Foundation According to Form Work Methods (거푸집 설치 방법에 따른 철도 전철주기초의 모멘트 저항 거동)

  • Lee, Su-Hyung;Lee, Seung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.411-417
    • /
    • 2013
  • The moment responses of electric pole foundations for a railroad were investigated using real-scale load tests. Large overturning moments were applied to two square rigid piles with a 1.1 m width and a 2.2 m embedded depth. Two different installation methods-with and without a form-were applied to evaluate the influence of the form work on the moment capacities of the foundations. The reduction of ground strength caused by the excavation without a form is more pronounce than the decrease of frictional strength due to the smooth concrete surface with a form. From the test results, it is found that the current design method which applies a proportional coefficient to consider the effect of a form work is not appropriate. When the normal and frictional stressed is considered separately, the effect of a form work can be estimated reasonably by reducing the friction angle between soil and foundation by 20%.

A development the system to assist planning and designing a route for transmission line based 3D GIS and CAD technology (3차원 GIS & CAD를 기반으로 하는 송전선로 경과지 선정시스템 개발)

  • Baik, Seung-Do;Kim, Tai-Young;Min, Byeong-Wook;Wi, Hwa-Bog;Choi, Jin-Sung;Bang, Hang-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.63-65
    • /
    • 2006
  • These days, it is not easy to construct the transmission line because of the environmental association activity, a civil appeal, etc. To solve these kinds of difficulties, the program with leading-edge IT technology, such as GIS, 3 dimensions CAD, computer graphic, etc., is developed to be more transparent and objective in the design stage of the transmission line and the selection stage of the transmission line route. Comparing this program with previous methods, this program is composed of the environmental evaluation program, data producing program for analysis and selecting line route program because it is not possible to conduct those kinds of work without any help from the computer and well-developed program. To confirm the performance of the program, the result from the program and the human were compared. Therefore, the result from the program was same as the result conducted by human. In addition, the program makes the selection of the transmission line route easier by checking the mountainside, lumbering, the estimated cost of the tower construction, etc. in real-time.

  • PDF

A Study on the Human body Model shocked Electric installation in Underwater (수중에서의 인체에 가해지는 전기적 현상에 관한 연구)

  • Woo, J.H.;Park, H.Y.;Song, W.C.;Kim, N.S.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1338-1339
    • /
    • 2008
  • In this paper, charging part by basic from Andrew's body model research to second a danger have affect on remaining and rehabilitation humans in space under water. The construction of a circuit make to Andrew's body model. It compare that voltages measure a hand, a breast, a groin and electric currents measure an arm, a breast, a leg with safety a limit of body through an electric current. Out of result, it research that magnitude and wave of body passing an electric current give the effect to the heart control a signal and it have affect on direct the ventricle of the heart in detail motion. A thing of this sort get through to the simulation by the ATP-Draw program. The results from above, it is publish one's research work with safety a limit electric angle take measurement of resistance a body in under water and to the voltage and electric current passing each parts.

  • PDF