• Title/Summary/Keyword: electric wire

Search Result 744, Processing Time 0.027 seconds

TLP and Wire Bonding for Power Module (파워모듈의 TLP 접합 및 와이어 본딩)

  • Kang, Hyejun;Jung, Jaepil
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.7-13
    • /
    • 2019
  • Power module is getting attention from electronic industries such as solar cell, battery and electric vehicles. Transient liquid phase (TLP) boding, sintering with Ag and Cu powders and wire bonding are applied to power module packaging. Sintering is a popular process but it has some disadvantages such as high cost, complex procedures and long bonding time. Meanwhile, TLP bonding has lower bonding temperature, cost effectiveness and less porosity. However, it also needs to improve ductility of the intermetallic compounds (IMCs) at the joint. Wire boding is also an important interconnection process between semiconductor chip and metal lead for direct bonded copper (DBC). In this study, TLP bonding using Sn-based solders and wire bonding process for power electronics packaging are described.

Correlation between Velocity Fluctuation and Fluctuation of Hydrogen Concentration in 2-D Air-Hydrogen Supersonic Mixing Layer

  • Sakima, Fuminori;Arai, Takakage;Edward, Shelley-R.;Mori, Yuko
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.111-116
    • /
    • 2004
  • An experiment was carried out to confirm the validity of time series evaluation of supersonic mixing condition by using catalytic reaction on a platinum wire. Geseous hydrogen was injected parallel to supersonic freestream (M$\infty$ $\approx$ 1.81) from a slit injector, which was located at backward facing step. Time series condition of supersonic mixing was evaluated by using W-type probe which has a platinum wire and reference wire (nickel wire). The evaluation was by simultaneously measuring each electric circuit which kept the temperature of wire constant. Investigations were also conducted for helium, air and no secondary injectant cases to compare with the hydrogen injectant case. The results indicated that it was possible to measure the time series behavior of air and hydrogen supersonic mixing layer or coherent motion of turbulence by using this evaluation.

  • PDF

Machining Characteristics of Wire EDM Using ER Brake System (ER 제동장치를 적용한 와이어 컷 방전의 가공 특성)

  • 김기선
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.11
    • /
    • pp.171-178
    • /
    • 2004
  • This paper presents vibration characteristics of a wire cut discharge machine in which an electro-rheological brake actuator is used to control the wire tension. The ER brake actuator has several advantages including design simplicity, fast response time and real-time controllability. On the basis of the tension level required in the machine an appropriate size of the ER brake actuator is devised. The ER brake actuator is then incorporated with the machine and the field-dependent wire tension is experimentally evaluated. The straightness of the workpiece is also empirically investigated by changing the intensity of the electric field.

The Study on Application of Flying Inspection Method for the 22.9kV Distribution Line (22.9kV 배전선로 비행점검 방법 적용에 관한 연구)

  • Zhang, Jeong-Il;Kang, Byoung-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.194-198
    • /
    • 2012
  • This paper describes flying inspection apparatus for 22.9kV distribution line. This apparatus is composed of multi-copter(more than 4 propellers), camcorder and remote controller. The existing inspections, such as hot-line inspection job and optical inspection method and distribution Line Checking Robot, have many restrictions. A electric working vehicle and hot-line job license are essential in hot-line inspection job. Besides its high cost, it can't be applied to the electric pole over 18m and road-blocked area. Optical method can't inspect upper side of electric facilities mounted on the electric pole. Robot method can't be applied to the corroded overhead earth wire and nothing of overhead earth wire. To solve the problems, in Korea Electric Power Co., we have applied flying inspection apparatus to the 22.9kV distribution line. The results of trial application show that this paper is practical and effective for the inspection technical method in 22.9kV distribution line

Positive Research of Client-Server Interlock System for m-PACS Rehalibitated Service in Wire less Mobile Environment (무선이동환경에서 m-PACS 재활지원 서비스를 위한 클라이언트-서버 연동시스템의 실증적연구)

  • Kim, Whi-Young;Choe, Jin-Yeong;Park, Seong-Jun;Kim, Jin-Yeong;Park, Seong-Jun;Kim, Hui-Je
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2169-2170
    • /
    • 2006
  • J2ME service technology has advantage that can embody independent and, more soft system in DICOM 3.0 and medicine reflex administration server, client's OS that is medical treatment reflex standard in radio Internet. Also, intranet that do web basedspread, and develop by system that can alternate existent client-server structure rapidly. Specially, posibility of improvement is much because is connecting being limited in internet environment that medical equipment and information system of various kinds of machine are wire in medical institution and so on. Because do medical treatment reflex transmission module development applying DICOM technology and filtering techniques of "m-PACS Rehalibitated " in this research, existence, by interlock in radio usable Mobile reflex conversion system design and embody. That is, patient's information which is stored to various systems to be transmited and can give big help in medical examination and treatment to reflex client without being wooed doctor's interpretation result and so on in place through environment to be radish tentacle bar see

  • PDF

The Properties Analysis of 600V Grade Polyvinyl Chloride Insulated Wire with Variation of Thermal Stress (열적 스트레스 변화에 따른 600V 비닐절연전선의 특성 분석)

  • 최충석
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.108-115
    • /
    • 2001
  • In this paper, we analyzed the properties change of electric wire when the thermal stress was applied to 600V grade polyvinyl chloride insulated wire (IV). In the structure analysis, normal wire has the properties of direction on the surface, but in case of deteriorated wire at above $400^{\circ}c$, it formed the carbide, the crack and the crystal. The surface composition rate of normal wire was Cu : 100%, but the section composition of the deteriorated wire at $800^{\circ}c$ showed Cu : 78.89%, O : 21.11%. In result of analyzing the differential scanning calory of copper wire, the new reaction peak was observed on the deteriorated wire at above $700^{\circ}c$. In case of the deteriorated wire as $150^{\circ}c$ at the differential thermal analysis, an endothermic reaction appeared at $264^{\circ}c$ lower than the reactive point of normal wire. The occupation rate of oxygen according to the deterioration of copper wire is about 20% at $500^{\circ}c$.

  • PDF

A Study on the Thermal Characteristics of Wire Connection Part Depending on the Screw Torque (나사조임토크에 따른 전선접속부의 열적특성에 관한 연구)

  • Kim, Si-Kuk;Jee, Seung-Wook;Park, Sang-Min;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.82-88
    • /
    • 2012
  • To analyze the thermal characteristics of wire connection part that is connected to a screw-clamping terminal block depending on screw torque, the normal screw torque defined in KS C 2625 and the abnormal screw torque that can occur due to loosened screws resulting from defective work or aged deterioration were used as experimental variables. After the same load was applied to normal and abnormal screw torques, the thermal characteristics of the wire connector were measured and compared with a thermal imaging camera. The findings from this study will be used to detect heating due to defective screw torque at terminal block connections during electric safety inspection in the future and minimize the hazard of electric fire.

The Analysis of Metallurgical Structure and Arc Properties of Copper Wire Due to Over-current (과전류에 의한 동 전선의 용단 아크 특성 및 금속조직 분석)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Dong-Ook;Lee, Ki-Yeon;Choi, Chung-Seog
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.554-555
    • /
    • 2005
  • In this paper, we analyzed a metallurgical structure and arc properties of copper wire when the over-current flows on electric wire. From the results, The fusing current was related to the fusing time(current rising rate per second). In case of the shorter the fusing time, the fusing current was high, and the fusing time of ac type was larger than that of dc type. The copper wire was bent by the increase of current and heated, the beads were scattered around wire with a flash. We could observed the dendrite structure in 'molten wire at ac and dc current type. According as the current rising rate per second is short, the dendrite structure is distributed in surface of wire.

  • PDF

Development of Digital Fault Detection Systems for Screening Open and Short of Wire Harness (와이어 하네스 단선 단락 선별을 위한 디지털 고장 검출 시스템 개발)

  • A Ran Kim;Jae Wan Park;Ha Seon Kim;Jae Hoon Jeong;Sun Young Kim
    • Journal of Drive and Control
    • /
    • v.20 no.4
    • /
    • pp.140-149
    • /
    • 2023
  • Wire harness is a component for efficient control when electronic parts are required such as construction machinery and electric vehicles. With emerging issues such as autonomous driving and automation in construction, a wire harness composed of multiple cables has become an essential part because more electronic parts are required. However, when a wire harness failure occurs, systems can be stopped, accidents can occur, and economic damage can be significant. Therefore, in this paper, we developed a digital fault screening system that could easily and quickly diagnose faults in the wire harness. The principle of the developed system was to sequentially send pulse signals to the wire harness and use returned signals to perform fault detection. As a result of diagnosing faults using the developed failure detection system, a detection accuracy of 99.9 % was confirmed through the experiments.

Neutral Line Current Analysis of Three-phase Four-wire Power System (3상 4선식 전력 시스템의 중성선 전류 분석)

  • Min Joon-Ki;Kim Hyng-Chul;Kim Su-Chel;Choi Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.492-494
    • /
    • 2006
  • Neutral line current is analyzed by the neutral line CF in nonlinear load balanced and unbalanced conditions. The worst nonlinear load condition is nonlinear balanced load condition, and It is below CFNL=1.194 that a neutral line current could not excess the rated value

  • PDF