• 제목/요약/키워드: electric wave

검색결과 797건 처리시간 0.026초

전기장하에서의 담배 및 완두 원형질체 융합 (Electrofusion of Tobacco and Pea Protoplasts)

  • 서정우
    • Journal of Plant Biology
    • /
    • 제29권1호
    • /
    • pp.1-10
    • /
    • 1986
  • Intra- and inter-specific protoplast fusion of tobacco (Nicotiana tabacum cv. Virginia 115) and pea (Pisum sativum cv. Sparkle) were carried out in highly inhomogeneous alternating electric fields. Under the electric field of alternating current (AC, sine wave), 600 V/cm and 800 kHz for tobacco protoplast, and 600 V/cm and 700 kHz for pea protoplasts, the protoplasts were aggregated in pearl chains. Intra-specific protoplast fusions were most effectively induced within the aggregates of tobacco and pea, respectively, by the additional application of a single high field pulse of direct current (DC, square wave) at 1 kV/cm for 50 $mutextrm{s}$. Inter-specific fusions between protoplasts of the two plants were most effectively induced in the electric field of 600 V/cm and 700 kHz, and square wave pulse at 1 kV/cm for 50 $mutextrm{s}$. The duration of the pulse over the electrical breakdown voltages was simulated from 1 to 100 $mutextrm{s}$ in both tobacco and pea protoplast. The yield of the electrofusion products was significantly high (above 60%), compared with that (20%) of the standard fusion method by polyethylene glycol (PEG) 4,000, and the viability of electrofused protoplasts was above 70%, but that of PEG-fused protoplasts 8~16%, when determined by Evan's blue staining method.

  • PDF

도심의 전파 사각 지역 문제 해결을 위한 VANET 경고 메시지 전달 기능의 개선 (A performance Enhancement of VANET Warning Message Propagation on Electric Wave Blind Area Problem in the Urban Environment)

  • 이원열
    • 한국멀티미디어학회논문지
    • /
    • 제17권10호
    • /
    • pp.1220-1228
    • /
    • 2014
  • Emergency Warning Service will be the most important service of VANET. Transmission delay is the most important performance criteria of the warning service. Most legacy research takes a way to minimize the packet collision. However those approach has a critical weak point on urban environment where there is a blind area of electric wave. So another issue is required in order to provide enhanced warning message propagation technique to overcome the urban environment problem. In this paper, I proposed an enhanced warning message propagation scheme in the poor electric wave environment as the intersection area. Proposed scheme forwards the warning message to the blind area by enhanced forwarding node selection technique. For efficiency of warning message propagation, I suggest forwarding priority for decision of forwarding node. And the node has a direct mode or redirect mode depending on neighbor nodes. The simulation was carried out to evaluate the performance. The simulation results show that proposed scheme has the superior performance compared to legacy warning message technique.

A Novel Seamless Direct Torque Control for Electric Drive Vehicles

  • Ghaderi, Ahmad;Umeno, Takaji;Amano, Yasushi;Masaru, Sugai
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.449-455
    • /
    • 2011
  • Electric drive vehicles (EDV) have received much attention recently because of their environmental and energy benefits. In an EDV, the motor drive system directly influences the performance of the propulsion system. However, the available DC voltage is limited, which limits the maximum speed of the motors. At high speeds, the inverter voltage increases if the square wave (SW) voltage (six-step operation) is used. Although conventional direct torque control (DTC) has several advantages, it cannot work in the six-step mode required in high-speed applications. In this paper, a single-mode seamless DTC for AC motors is proposed. In this scheme, the trajectory of the reference flux changes continuously between circular and hexagonal paths. Therefore, the armature voltage changes smoothly from a high-frequency switching pattern to a square wave pattern without torque discontinuity. In addition, because multi-mode controllers are not used, implementation is more straightforward. Simulation results show the voltage pattern changes smoothly when the motor speed changes, and consequently, torque control without torque discontinuity is possible in the field weakening area even with a six-step voltage pattern.

A Novel Procedure for Protection Setting in an HVDC System Based on Fault Quantities

  • Gao, Benfeng;Zhang, Ruixue;Zhang, Xuewei
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.513-521
    • /
    • 2017
  • HVDC protection setting is difficult to be calculated analytically because of its strong nonlinearity. The currently used setting method is based on the empirical setting of previous projects and then verified by digital simulation. It entails a huge workload and low efficiency. To facilitate protection setting, this paper systematically summarizes the HVDC protection characteristics and then presents a classification of HVDC protections according to the protection principles. On the basis of the fault quantities, a novel setting procedure suitable for travelling wave protection, derivative and level protection, and differential protection is proposed. The proposed procedure is illustrated and verified in detail with the example of travelling wave protection. An HVDC protection setting system that has the functions of automatic protection setting and data management is developed utilizing the C# programming language.

경계요소법에 의한 3차원 유전체 구의 산란파 수치해석 (Numerical Analysis of the Electromagnetic Waves scattered from a dielectric sphere by the BEM)

  • 김정혜
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1990년도 제5회 파동 및 레이저 학술발표회 5th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.64-68
    • /
    • 1990
  • Boundary element method using linear basis function is applied to obtain fields scattered from a 3-D dielectric sphere. Electric field integral equation is used on the surfaces of the dielectric material where its surface is discretized into trilateral cells. For plane wave incidence, scattered fields by a dielectric sphere is calculated and compared with its analytic solution. The total electric fields are calculated on the great circle of the sphere boundary as well as the outside of the sphere in the plane of the wave vector and the polarization vector of the incident electric field.

  • PDF

전자기파 부분방전 신호의 권선 투과 특성 (Partial Discharge Electromagnetic Wave Penetration Characteristics Throughout Transformer Winding)

  • 주형준;한기선;윤진열
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.809-813
    • /
    • 2010
  • Frequency domain measurement of propagation loss for ultra high frequency (UHF) partial discharge in the winding of power transformer using a spectrum analyzer and pulse generator is presented. We compared the performance of the method using a network analyzer with and without a winding. Using a network analyzer simplifies the measurement and offers better dynamic range and frequency range. It also provides precise propagation loss within the winding in frequency domain at UHF range. We applied this method to measure UHF propagation loss of transformer mock-up, modeled 154 kV 20 MVA power in KEPCO substation.

Investigation on Terahertz Generation by GaP Ridge Waveguide Based on Cascaded Difference Frequency Generation

  • Li, Zhongyang;Zhong, Kai;Bing, Pibin;Yuan, Sheng;Xu, Degang;Yao, Jianquan
    • Journal of the Optical Society of Korea
    • /
    • 제20권1호
    • /
    • pp.169-173
    • /
    • 2016
  • Terahertz (THz) generation by a GaP ridge waveguide with a collinear modal phase-matching scheme based on cascaded difference frequency generation (DFG) processes is theoretically analyzed. The cascaded Stokes interaction processes and the cascaded anti-Stokes interaction processes are investigated from coupled wave equations. THz intensities and quantum conversion efficiency are calculated. Compared with non-cascaded DFG processes, THz intensities from 11-order cascaded DFG processes are increased to 5.48. The quantum conversion efficiency of 177.9% in cascaded processes can be realized, exceeding the Manley-Rowe limit.

Application of Pulsed Electric Fields with Square Wave Pulse to Milk Inoculated with E. coli, P. fluorescens, and B. stearothermophilus

  • Shin, Jung-Kue;Jung, Kwan-Jae;Pyun, Yu-Ryang;Chun, Myong-Soo
    • Food Science and Biotechnology
    • /
    • 제16권6호
    • /
    • pp.1082-1084
    • /
    • 2007
  • Ultra-high temperature (UHT) processed full fat milk inoculated with Escherichia coli, Pseudomonas fluorescens, and Bacillus stearothermophilus was exposed to 30-60 kV/cm square wave pulsed electric field (PEF) with $1\;{\mu}sec$ pulse width, and $26-210\;{\mu}sec$ treatment time in a continuous PEF treatment system. Eight log reduction was obtained for E. coli and P. fluorescens and 3 logs reduced for B. stearothermophilus under PEF treatment conditions of $210\;{\mu}sec$ treatment time, 60 kV/cm pulse intensity at $50^{\circ}$. There was no significant change in pH and titration acidity of milk after PEF treatment. The electrical energy required to achieve 8 log reduction for E. coli and P. fluorescens was estimated to be about 0.74 kJ/L.

오대산지진(M=4.8, '07. 1. 20)의 지진파 전달특성 평가 (Spectral Features of Seismic Wave Propagation from Odaesan Earthquake (M=4.8, '07. 1. 20))

  • 연관희;박동희;장천중
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.81-86
    • /
    • 2007
  • Spectral features of the seismic wave propagation from Odaesan Earthquake were evaluated based on the commonly treated random error between the observed data and the prediction values by the stochastic point-source ground-motion spectral model regarding the source, path and site effects. Radiation pattern of the error according to azimuth angle was found to be similar to the theoretical estimate. It was also observed that the spatial distribution of the errors was correlated with the geological map and the Q0 map which are indicatives of seismic boundaries.

  • PDF

인버터 저항 점용접 장치의 PWM제어에 관한 연구 (Study on PWM Control in Inverter Resistance Spot Welding)

  • 권효철;최용범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.169-171
    • /
    • 2006
  • Nowadays, inverter welding is risen in spot welding, because can secure productivity. This study made changed output wave form of inverter welding equipment by several forms and measured electric current that pass to the second of transformer for welding. Purpose of study is finding electric current of most suitable form. Also, studied applies PID control in electric current control of inverter resistance weld device and heightens electric current precision.

  • PDF