• 제목/요약/키워드: electric resistance values

검색결과 93건 처리시간 0.019초

전기적 접속/접촉부 열화 평가를 위한 수명 온도상승 모델 (Lifetime-Temperature Rise Model for the Evaluation of Degradation in Electric Connections/Contacts)

  • 김정태;김남준
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권2호
    • /
    • pp.55-61
    • /
    • 2002
  • In this paper, 'lifetime-temperature rise model' based on the 'lifetime-resistance model' is theoretically Proposed, in order to find out the evaluation method of degradation and the residual lifetime by use of infrared image camera for electric connections/contacts. Two assumptions have been builded up for the 'lifetime-temperature rise model': one is associated with the linear relationship between the temperature ism ΔK and contact resistance, and the other the functional relationship between the temperature of electric connections/contacts and the operating time presenting in the 'lifetime-resistance model'. To prove the proposed model, experiments have been performed for various electric connections/contacts. From the experimental results, measured values were quite similar to the calculated values, which proved the above-mentioned two assumptions. Therefore, by use of 'lifetime-temperature rise model', it is possible to estimate the trend of degradation and the residual lifetime for electric connections/contacts through the temperature measurements .

Study on EMTP Simulation Applying Dual Reactor for Prevention of the Ferro-resonance and VT Burnout in Substation System

  • Kim, Seok-kon;An, Yong-ho;Jang, Byung-tae;Choi, Jong-kee;Lee, Nam-ho;Han, Jung-yeol;Lee, You-jin
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.1-8
    • /
    • 2015
  • When the line and switchgear of the substation system are disconnected, ferro-resonance can occur. This happens even if the capacitive reactance and inductive reactance are not equal, which are not common resonance conditions. Resonance conditions vary depending on the busbar configuration environment. Although the damping resistance method applying the existing saturable reactor to cope with ferro-resonance has been successfully applied on site, there can be loss of normal function during long-term operation. The reason is because the rise in the operating frequency of saturable reactors means the saturation number is increased. Therefore, it can no longer function as saturable reactor since the resistor having inadequate capacity is burned out. To address this problem, in this paper, an EMTP-based simulation test was performed by designing and applying a dual reactor method, which adds an extended divergence reactor to the 1st side of the VT. The test result confirms that when the divergence reactor is inserted, the voltage and current values obtained at the 1st side and 2nd side of the VT as well as current values of divergence reactor part were stabilized from the transient phenomena and return to normal values. When compared with existing measures, although this method is similar in adding having a reactor added to a system regarding ferro-resonance, it has the advantage of being able to prevent ferro-resonance in advance since the reactor is added before the system is saturated. In addition, because it does not use damping resistance, it can extend the equipment life and stabilize its operation. Therefore, there are a lot of differences in terms of its operating characteristics and achivement of goal between the conventional method and new divergence reactor method.

표면 열전달 저항이 배제된 건물 벽체 열성능 현장 측정 기법 (In-situ Measurement Technique for Thermal Performance of Building Wall Excluding Surface Heat Transfer Resistance)

  • 김승철;김상봉;나환선
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권2호
    • /
    • pp.151-155
    • /
    • 2020
  • In this paper, a new experimental method to determine the thermal resistance of building wall was proposed by improving the heat flow method (HFM) based on the air-surface temperature ratio theory. This technique measures the thermal resistance of the wall excluding the inner and outer surface heat transfer resistance. Unlike conventional HFM, this value can be compared directly with the theoretical reference value. Its performance was verified using three mock-up structures with a theoretical thermal transmittance of 0.5, 3.3, and 0.18 W/㎡·K respectively. After measuring the variations in the temperature and heat transfer rate of the mock-ups for 383 hours, the thermal transmittances were determined to be 0.47, 3.10, and 0.18 W/㎡·K, which corresponded to errors of 5.2, 6.2 and 0.5%, respectively, compared to the theoretical values. It was concluded that this technique can directly compare the thermal resistance of the wall between the existent stage and initial stage after construction.

도체접속부 열화에 대한 수명온도상승 모델 (Lifetime Temperature Rise Model for the Degradation of Electric Connections/Contacts)

  • 김정태;김지홍;구자윤;윤지호;함길호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1611-1613
    • /
    • 2000
  • In this study in order to find out the trends and the residual lifetime for electric connections/contacts using infrared image camera, "lifetime temperature rise model" is theoretically proposed on the base of "lifetime resistance model" and to prove this theory, experiments have been performed for various kinds of electric connections/contacts. Two suggestions have been builded up or the "lifetime temperature rise model" ; one is the linear relationship between the temperature rise $\Delta K$ and contact resistance, and the other is the functional relationship between the temperature of electric connections/contacts and the operating time which ascribed in the "lifetime resistance model". From the experimental results, measured values were quite similar to the theoretical value so that two suggestions in "lifetime temperature rise model" were appeared to be correct.

  • PDF

A new geophysical exploration method based on electrical resistivity to detect underground utility lines and geological anomalies: Theory and field demonstrations

  • Jo, Seon-Ah;Kim, Kyoung-Yul;Ryu, Hee-Hwan
    • Geomechanics and Engineering
    • /
    • 제18권5호
    • /
    • pp.527-534
    • /
    • 2019
  • Although ground investigation had carried out prior to the construction, many problems have arisen during the civil-engineering works because of the presence of the unexpected underground utility lines or anomalies. In this study, a new geophysical exploration method was developed to solve those problems by improving and supplementing the existing methods. This new method was based on the difference of electrical resistance values between anomalies and surrounding ground medium. A theoretical expression was suggested to define the characteristics of the anomalies such as location, size and direction, by applying the electric field analysis. An inverse analysis algorithm was also developed to solve the theoretical expression using the measured electrical resistance values which were generated by the voltage flowing the subsurface medium. To verify the developed method, field applications were conducted at the sites under construction or planned. From the results of the field tests, it was found that not only the new method was more predictive than the existing methods, but its results were good agreed with the measured ones. Therefore, it is expected that application of the new exploration method reduces the unexpected accidents caused by the underground uncertainties during the underground construction works.

石炭의 黑鉛性에 關한 硏究 (第1報) (Studies on the Electric Resistecna of Coals (1))

  • 오신섭;이석원
    • 대한화학회지
    • /
    • 제5권1호
    • /
    • pp.22-25
    • /
    • 1961
  • The attempt to distinguish between graphite and domestic anthracite was means, especially electric resistance. The specific resistance values of various coals and graphites were determined by Wheaston Bridge equipped with more finely adjustable slide wire. The result of graphite was in the below of 0.08 ohm-cm and that of anthracite has $10^{-1}{\sim}10^1$ohm-cm range.

  • PDF

전동 스쿠터 동력장치 설계 (A Driving System Design of an Electric Motor Scooter)

  • 김문환
    • 한국자동차공학회논문집
    • /
    • 제19권5호
    • /
    • pp.1-6
    • /
    • 2011
  • This paper proposes a new design method for electric scooter which can maximize the power efficiency at the given driving condition. The proposed method is designed with the electric and mechanical parameters and driving dynamics. These values are extracted from the dynamic and mathematical equations of the scooter. For validation, numerical simulation results are presented in this paper. As a result, the scooter achieved over 80% efficiency at 360 rpm at 1.42kw load. It is clear that the proposed method was verified through a 1.42kw numerical model.

Effects of surface-roughness and -oxidation of REBCO conductor on turn-to-turn contact resistance

  • Y.S., Chae;H.M., Kim;Y.S., Yoon;T.W., Kim;J.H., Kim;S.H., Lee
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권4호
    • /
    • pp.40-45
    • /
    • 2022
  • The electrical/thermal stabilities and magnetic field controllability of a no-insulation (NI) high-temperature superconducting magnet are characterized by contact resistance between turn-to-turn layers, and the contact resistance characteristics are determined by properties of conductor surface and winding tension. In order to accurately predict the electromagnetic characteristics of the NI coil in a design stage, it is necessary to control the contact resistance characteristics within the design target parameters. In this paper, the contact resistance and critical current characteristics of a rare-earth barium copper oxide (REBCO) conductor were measured to analyze the effects of surface treatment conditions (roughness and oxidation level) of the copper stabilizer layer in REBCO conductor. The test samples with different surface roughness and oxidation levels were fabricated and conductor surface analysis was performed using scanning electron microscope, alpha step surface profiler and energy dispersive X-ray spectroscopy. Moreover, the contact resistance and critical current characteristics of the samples were measured using the four-terminal method in a liquid nitrogen impregnated cooling environment. Compared with as-received REBCO conductor sample, the contact resistance values of the REBCO conductors, which were post-treated by the scratch and oxidation of the surface of the copper stabilizer layer, tended to increase, and the critical current values were decreased under certain roughness and oxidation conditions.

톱밥과 왕겨로 제조된 세라믹의 전기적 성질과 원적외선 방사특성 (Electrical Properties and Far-infrared Ray Emission of Ceramics Manufactured with Sawdust and Rice Husk)

  • 오승원
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권1호
    • /
    • pp.106-112
    • /
    • 2016
  • 농림 부산물인 톱밥과 왕겨를 이용하여 세라믹을 제조하고 페놀수지 함침율과 탄화 온도에 따른 전기적 성질 및 원적외선 방사특성을 조사하였다. 원적외선 방사율과 방사 에너지 값은 탄화온도가 증가함에 따라 감소하였으며, 수지함침율 60%, 탄화온도 $600^{\circ}C$일 때 원적외선 방사율은 0.930, 방사에너지는 $4.32{\times}10w/m^2$로 가장 높았다. 전기저항 값은 탄화온도가 증가함에 띠라 감소하여 $1200^{\circ}C$ 이상에서는 거의 도체에 가까운 성질을 보였다. 소비전력은 수지함침율이 높을수록 전기저항의 감소와 전류의 증가로 함께 증가하였다.

레지스토그래피를 이용한 수령조사 가능성 검토 (Verifying the Possibility of Investigating Tree Ages Using Resistograph)

  • Oh, Jung-ae;Seo, Jeong-Wook;Kim, Byung-Ro
    • Journal of the Korean Wood Science and Technology
    • /
    • 제47권1호
    • /
    • pp.90-100
    • /
    • 2019
  • 본 연구는 수목의 수령을 조사하는 방법으로 레지스토그래피를 활용하는데 있어서 수종별로 가장 적합한 삽입속도를 찾기 위하여 수행되었다. 회전속도는 1,500 r/min로 고정하였다. 수종은 낙엽송, 더글라스 퍼, 잣나무, 전나무, 느티나무이다. 실험결과 수종에 따른 적합한 삽입속도는 느티나무 75 cm/min, 낙엽송과 더글라스 퍼 100 cm/min, 전나무 150 cm/min, 잣나무 175 cm/min으로 나타났다. 하지만 모든 경우에서 연륜폭이 1 mm이하일 경우 연륜경계 확인이 어려운 것으로 확인되었다. 연륜폭이 1 mm이하인 경우를 제외하고는 연륜폭측정기와 레지스토그래피의 연륜폭그래프는 매우 일치하였다. 향후 연륜폭이 1mm 이하인 미세연륜 확인이 가능한 레지스토그래피가 개발된다면 레지스토그래피가 수령조사를 위해 전통적으로 활용되는 생장편의 연륜관찰방법을 대체할 수 있을 것이다. 또한 레지스토그래피의 연륜폭그래프는 생장량 조사에도 활용할 수 있을 것으로 판단된다.