• 제목/요약/키워드: electric pulse

검색결과 638건 처리시간 0.026초

스터링헝 오리피스 맥동관 냉동기의 성능특성에 관한 연구 (Study of the performance characteristics of the Stirling type orifice pulse tube refrigerator)

  • 홍용주;박성제;김효봉;김양훈;최영돈
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권2호
    • /
    • pp.63-67
    • /
    • 2002
  • In this study, the performance of the Stirling type orifice Pulse tube refrigerator (OPTR) with a linear compressor was investigated by experiment. The dynamic pressures at three points and a temperature at the cold heat exchanger are measured to explore the dependency of the orifice on the performance of the OPTR. The experimental results show that the opening of the orifice has significant effects on the no load temperature and cool down characteristics. The Pressure amplitude in Pulse tube decrease as the opening of the orifice increase, but the mass flow rate through the orifice and the electric input Power to the compressor increase. The results show that the operating frequency and charging Pressure does not affect on the no load temperature. The pressure amplitude in pulse tube decrease as the operating frequency increase or the charging Pressure decreased.

한방용(韓方用) 맥파 검출시스템 (Radial Pulse Wave Detection system for the Korean Medicine)

  • 이호재;김진우;김흥오;박영배;허웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1991년도 추계학술대회
    • /
    • pp.66-69
    • /
    • 1991
  • This paper describes a design of transducer for non-invasively detecting pressure radial pulse wave in aterial system and a recording system that for the studing the aterial pulse diagnosis of korean traditional medicine. The mechanism of transducer is composed of sensing mechanism, pressure sensor, conditioning amplifier. The variation of radial pulse pressure in the sensing mechanism is converted to the electric signal by piezo-resistive pressure sensor and it converted to the digital signal after preprocessing via A/D converter. The converted signals inputed to the computer as data files and then it display to the monitor for waveform watching and this datas can be used as the aterial pulse diagnosis data. This system effectively detect non-differential radial pulse wave and we conside that if analizing the recorded radial pulse wave, compared each other, it can be helpful in quantify radial pulse wave diagonosis of the Korean traditional medicine.

  • PDF

Non-iterative pulse tail extrapolation algorithms for correcting nuclear pulse pile-up

  • Mohammad-Reza Mohammadian-Behbahani
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4350-4356
    • /
    • 2023
  • Radiation detection systems working at high count rates suffer from the overlapping of their output electric pulses, known as pulse pile-up phenomenon, resulting in spectrum distortion and degradation of the energy resolution. Pulse tail extrapolation is a pile-up correction method which tries to restore the shifted baseline of a piled-up pulse by extrapolating the overlapped part of its preceding pulse. This needs a mathematical model which is almost always nonlinear, fitted usually by a nonlinear least squares (NLS) technique. NLS is an iterative, potentially time-consuming method. The main idea of the present study is to replace the NLS technique by an integration-based non-iterative method (NIM) for pulse tail extrapolation by an exponential model. The idea of linear extrapolation, as another non-iterative method, is also investigated. Analysis of experimental data of a NaI(Tl) radiation detector shows that the proposed non-iterative method is able to provide a corrected spectrum quite similar with the NLS method, with a dramatically reduced computation time and complexity of the algorithm. The linear extrapolation approach suffers from a poor energy resolution and throughput rate in comparison with NIM and NLS techniques, but provides the shortest computation time.

사과주스의 품질에 미치는 pulsed electric field 연속 처리효과 (Effect of continuous pulsed electric fields treatments on quality of apple juice)

  • 안성환;임정호;김영호;정석진;박기재
    • 한국식품저장유통학회지
    • /
    • 제20권5호
    • /
    • pp.650-658
    • /
    • 2013
  • 전기장의 세기 20 kV/cm, 펄스 폭 25 ${\mu}s$에서 펄스 빈도 35 Hz(40 kJ/L), 55 Hz(70 kJ/L), 72 Hz(100 kJ/L) 및 85 Hz(130 kJ/L)로 달리하여 투입 에너지를 기준으로 사과 착즙액의 PEF 연속처리 살균 효과를 분석한 결과 일반세균수은 초기 5.3 log CFU/mL에서 130 kJ/L의 에너지로 처리하였을 때 3.0 log CFU/mL로 감소하였고 효모 및 곰팡이는 초기 4.6 log CFU/mL에서 130 kJ/L의 에너지로 처리로 < $10^1$ CFU/mL 이하로 감소하였다. 그리고 대장균군수도 초기 4.7 log CFU/mL에서 130 kJ/L의 에너지 처리로 < $10^1$ CFU/mL 이하로 감소하였다. PEF 처리에 따른 가용성 고형분, 유리당 등에는 처리 조건에 따른 유의적 차이가 없었으며(p<0.05), 총 페놀함량, DDPH 및 FRAP 값은 처리조건에 따라 부분적으로 유의적인 감소를 보였지만 $65^{\circ}C$에서의 가열처리보다는 감소량이 작았다. 전기장 세기 20.0 kV/cm, 펄스 빈도 85 Hz, 펄스 폭 25 ${\mu}s$에서의 반복처리는 미생물 살균 효과가 제한적이었고 처리회수에 따라 총 페놀함량, DPPH 및 FRAP 값을 유의적(p<0.05)으로 감소시켰다.

Utility AC Frequency to High Frequency ACPower Conversion Circuit with Soft Switching PWM Strategy

  • Sugimura Hisayuki;Ahmed Nabil A.;Ahmed Tarek;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권2호
    • /
    • pp.181-188
    • /
    • 2005
  • In this paper, a DC smoothing filterless soft switching pulse modulated high frequency AC power conversion circuit connected to utility. frequency AC power source is proposed for consumer induction heating hot water producer, steamer and super heated steamer. The operating principle of DC link filterless utility frequency AC-high frequency AC (HF AC) power conversion circuit defined as high frequency cycloinverter is described, which can operate under a principle of ZVS/AVT and power regulation based on alternate asymmetrical PWM in synchronization with the utility frequency single phase AC positive or negative half wave voltage. The dual mode modulation control scheme based on high frequency PWM and commercial frequency AC voltage PDM for the proposed high frequency cycloinverter are discussed to enlarge its soft switching commutation operating range for wide HF AC power regulation. This high frequency cycloinverter is developed for high frequency IH Dual Packs Heater (DPH) type boiler used in consumer and industrial fluid pipeline systems. Based on the experiment and simulation results, this high frequency cycloinverter is proved to be suitable for the consumer use IH-DPH boiler and hot water producers. The cycloinverter power regulation and power conversion efficiency characteristics are evaluated and discussed.

알콜 탈수소효소의 안정도에 미치는 전기 자극의 효과 (Effect of Electro-stimulation on Stability of Alcohol Dehydrogenase from Horse Liver)

  • 이강민;김철생;이혜정;함대현;박충웅
    • 동의생리병리학회지
    • /
    • 제18권6호
    • /
    • pp.1723-1727
    • /
    • 2004
  • We investigated the activity and stability of alcohol dehydrogenase from horse liver (HLADH) under the electric stimulation. The activity and stability of alcohol dehydrogenase depended on electric output voltaqe, stimulation time, pulse duration and pulse interval, and temperature. HLADH retained about 23% of its activity in buffer but 78% in 10% trehalose solution under electric stimulation with 10V, 10min, The stabilizing of enzymes against electric stimulation by stabilizing additives showed a great potential use of enzymes in biotechnology and medical engineering fields.

신경회로망을 이용한 가공조건에 따른 원형가공 표면거칠리 평가 (Evaluation of Circle Machining Surface Roughness on the Process Conditions using Neural Network)

  • 성백섭;김일수;차용훈
    • 한국안전학회지
    • /
    • 제17권1호
    • /
    • pp.11-17
    • /
    • 2002
  • The purpose of this study was to present the method to choose the optimization machining condition for the wire electric machine. This was completed by examining the ever-changing quality of the material and by improving the function of the wire electric discharge machine. Precision metal mold products and the unmanned wire electric discharge machining system were used and then applied in industrial fields. This experiment uses the wire electric discharge machine with brass wire electrode of 0.25mm. To measure the precision of the machining surface, average values are obtained from 3 samples of measures of center-line average roughness by using a third dimension gauge and a stylus surface roughness gauge. In this experiment, we changed no-node voltage to 7 and 9, pulse-on-time to $6{\mu}s,\;8{\mu}s$ and $10{\mu}s$, pulse-off-time to $8{\mu}s,\;10{\mu}s$ and $13{\mu}s$, and experimented on wire tension at room temperature by 1000gf, 1200gf, and 1400gf, respectively.

Research on Grid Side Power Factor of Unity Compensation Method for Matrix Converters

  • Xia, Yihui;Zhang, Xiaofeng;Ye, Zhihao;Qiao, Mingzhong
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1380-1392
    • /
    • 2019
  • Input filters are very important to matrix converters (MCs). They are used to improve grid side current waveform quality and to reduce the input voltage distortion supplied to the grid side. Due to the effects of the input filter and the output power, the grid side power factor (PF) is not at unity when the input power factor angle is zero. In this paper, the displacement angle between the grid side phase current and the phase voltage affected by the input filter parameters and output power is analyzed. Based on this, a new grid side PF unity compensation method implemented in the indirect space vector pulse width modulation (ISVPWM) method is presented, which has a larger compensation angle than the traditional compensation method, showing a higher grid side PF at unity in a wide output power range. Simulation and experimental results verify that the analysis of the displacement angle between the grid side phase current and the phase voltage affected by the input filter and output power is right and that the proposed compensation method has a better grid side PF at unity.

ZigBee를 이용한 뇌졸중 치료용 무선 전기 자극기 개발 (Development of Wireless Neuro-Modulation System for Stroke Recovery Using ZigBee Technology)

  • 김국화;유문호;신용일;김형일;김남균;양윤석
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.153-161
    • /
    • 2007
  • Stroke is the second most significant disease leading to death in Korea. The conventional therapeutic approach is mainly based on physical training, however, it usually provides the limited degree of recovery of the normal brain function. The electric stimulation therapy is a novel and candidate approach with high potential for stroke recovery. The feasibility was validated by preliminary rat experiments in which the motor function was recovered up to 80% of the normal performance level. It is thought to improve the neural plasticity of the nerve tissues around the diseased area in the stroked brain. However, there are not so much research achievements in the electric stimulation for stroke recovery as for the Parkinson's disease or Epilepsy. This study aims at the developments of a wireless variable pulse generator using ZigBee communication for future implantation into human brain. ZigBee is widely used in wireless personal area network (WPAN) and home network applications due to its low power consumption and simplicity. The developed wireless pulse generator controlled by ZigBee can generate various electric stimulations without any distortion. The electric stimulation includes monophasic and biphasic pulse with the variation of shape parameters, which can affect the level of recovery. The developed system can be used for the telerehabilitation of stroke patient by remote control of brain stimulation via ZigBee and internet. Furthermore, the ZigBee connection used in this study provides the potential neural signal transmission method for the Brain-Machine Interface (BMI).