• Title/Summary/Keyword: electric pulse

Search Result 638, Processing Time 0.03 seconds

Pulse Density Modulated Zero Voltage Soft-Switching High-Frequency Inverter with Single Switch for Xenon Gas Dielectric Barrier Discharge Lamp Dimming

  • Sugimura, Hisayuki;Suh, Ki-Young;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.391-394
    • /
    • 2006
  • This paper presents soft switching zero voltage switching high frequency inverter for rare gas fluorescent lamp using dielectric-barrier discharge phenomenon. The simple high-frequency inverter can completely achieve stable zero voltage soft switching (ZVS) commutation for wide its output power regulation ranges and load variations under its constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operating principle is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZVS operation commutation, together with its output effective power regulation characteristics-based on the high frequency PDM strategy. The experimental operating performances of this high frequency Inverter are illustrated as compared with computer simulation results and experimental ones. Its light dimming characteristics due to power regulation scheme are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliance implemented here is proven from the practical point of view.

  • PDF

Pulp Vitality Evaluation and Comparison with Old Methods Using Pulse Oximetry (맥박산소측정기(pulse oximetry)를 이용한 치수 생활력 측정과 기존 방법과의 비교)

  • Kwon, Ik-Jae;Seo, Kwang-Suk;Kim, Jung-Wook;Chang, Ju-Hea;Kong, Hyoun-Joong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.12 no.1
    • /
    • pp.17-23
    • /
    • 2012
  • Background: This study evaluated pulp vitality of anterior permanent teeth using pulse oximetry (PO), which is already used for monitoring of patient's $SpO_2$ and pulse rates (PR). Also we compared with ice tests and electric pulp test (EPT). Methods: 9 teeth, endodontic treated, were selected as non-vital teeth group. 17 vital teeth were selected as control group. Our aim is to compare sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of ice test, electric pulp test and pulse oximetry, respectively. Pulse oximetry has two test results, $SpO_2$ and pulse rates. Also we calculated correlation and statistical significances by Pearson's test between EPT and pulse oximetry. Results: Sensitivity, specificity, PPV, NPV were calculated on each tests. Ice test has results of 1.00, 0.89, 0.94 and 1.00, respectively. EPT has results of 0.94, 0.78, 0.89 and 0.88 respectively. $SpO_2$ has results of 0.94, 1.00, 1.00 and 0.90, respectively. PR has results of all 1.00. Conclusions: PO showed relatively accurate, stable and objective results on both $SpO_2$ and PR. Percentage of ability of accurate diagnosis for vital teeth is 94% for ice test, 89% for EPT, 100% for $SpO_2$ and PR. Percentage of ability of accurate diagnosis for non-vital teeth is 100% for ice test, 88% for EPT, 90% for $SpO_2$ and 100% for PR. In additions, PR could be more accurate and significant tests than $SpO_2$.

Expansion Ratio and Ultimate Load of Pulse-Discharge Bulbed Anchors (펄스방전 그라운드 앵커의 확공특성 및 극한인발력에 관한 연구)

  • Kim, Nak-Kyung;Kim, Sung-Kyu;Joo, Yong-Sun;Seo, Hyo-Kyun;Kim, Sun-Ju
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.7
    • /
    • pp.5-10
    • /
    • 2009
  • The ground anchor is not usually used in soft clay and loose sand, because the pullout resistance of anchors can not be guaranteed. However, there is a method to increase the capacity of anchors using electric discharge geotechnical technologies, which are also known as pulse discharge and electric-spark technologies. The pulse-discharge anchor has a bulbed (or underreamed) bond length that is expanded by high voltage electrokinetic pulse energy. 24 anchors were installed in the weathered soil and sandy clay at the Geotechnical Experimentation Site at Sungkyunkwan University in Suwon, Korea. In this study, in order to define a relation between expansion rate of the anchor diameter and ultimate load, anchor load tests were carried out in accordance with testing procedures by AASHTO (AASHTO 1990) and FHWA (Weatheb 1998). And then several anchors were exhumed to measure the diameter of the pulse discharge anchors.

전기기기절연물중의 void pulse와 그 검출에 관한 연구

  • 성영권
    • 전기의세계
    • /
    • v.16 no.3
    • /
    • pp.21-27
    • /
    • 1967
  • We meet with the fact that a majority of electric machinery have been insulated to the state of solids & liquids or solids & gases, that is, with compound dielectrics. And also we can find voids caused by undesirbble structure, long-used material and so on. When it is discharged in a void or in the parts of gases of insulating material, the insulation of the machinery is gradually and finally destroyed through the effect of ozone, nitrogen-oxide, electronic pulses and so on. So we maybe conculded that it is necessary and important to detected void pulse and void corona in order to prevent sudden break down of electric machinery.

  • PDF

A Damped Sinusoidal Electromagnetic Pulse Generator using a Charged Line (충전선로를 이용한 Damped Sinusoidal 전자기펄스 발생장치)

  • Ryu, Ji-Heon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.136-142
    • /
    • 2006
  • A damped sinusoidal electromagnetic pulse generator was designed, fabricated and tested. The pulse generator consisted of an oscillator(a spark gap switch and an initially charged low impedance line) and a high impedance antenna. This generator was capable of producing damped sinusoidal pulses at closure of the spark gap switch. A Marx generator was employed to supply the Pulse generator with high voltage pulses. While the pulse generator was provided with the high voltage pulses of 200kV from the Marx generator, its output power was maximized by controlling the pressure of the gas contained in the spark gap switch. The output power of the damped sinusoidal electromagnetic pulse oscillator was 1.3GW and the amplitude of electric field radiated from the pulse generator was 4kV/m at the range of 25m.

A Study on Risk Assessments and Protection Improvement for Electric Power Infrastructures against High-altitude Electromagnetic Pulse (전력기반시설의 고 고도 핵 전자기파에 대한 위험성 검토 및 방호 개선방안 연구)

  • Chung, Yeon-Choon
    • Convergence Security Journal
    • /
    • v.19 no.3
    • /
    • pp.43-50
    • /
    • 2019
  • In a hyper-connected society, electric power infrastructures and information and communication infrastructures are the core of critical national infrastructures. However, electric power infrastructure is very deadly to high-frequency nuclear electromagnetic pulse (HEMP) threats recently issued by North Korea, so the resilience through rapid recovery after attack is directly related to the survivability of our country. Therefore, electric power infrastructure should take precedence over any other key infrastructure, with preemptive protection measures and fast recovery plans. In this paper, the characteristics of the HEMP threats was examined, and the risks and effective major protection measures of the electric power infrastructures are discussed. In the future, it is expected that it will be able to help establish the direction of enactment and revision of legal schems related to the 'high power EMP infringement prevention' for Korea's electric power infrastructures.

Pulse forming's switching control adopted a Transcranial Magnetic Stimulation Biomedical engineering, Dongju College University (펄스포밍의 스위칭 제어기술을 적용한 경두개 자기자극장치)

  • Kim, Whi-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.3
    • /
    • pp.729-736
    • /
    • 2010
  • In this study, a magnetic stimulation (MS) device with controllable pulse forming technology and pulse shape (MS) is described. The MS device uses an IGBT with appropriate snubbers to switch coil currents up to 6 kA, enabling pulse forming technology control from 5 s to over 100 s. The induced electric field pulses use 2% - 34% less energy and generate 57% - 67% less coil heating compared to matched conventional cosine pulses. MS is used to stimulate rhesus monkey motor cortex in vivo with pulse forming technology of 20 to 100 s, demonstrating the expected decrease of threshold pulse amplitude with increasing pulse forming technology. The technological solutions used in the MS prototype can expand functionality, and reduce power consumption and coil heating in MS, enhancing its research and therapeutic applications.

Effect of Dynamic Electric Fields on Dielectric Reliability in Cu Damascene Interconnects (동적인 전기장이 다마신 구리 배선에서의 절연파괴에 미치는 영향)

  • Yeon, Han-Wool;Song, Jun-Young;Lim, Seung-Min;Bae, Jang-Yong;Hwang, Yuchul;Joo, Young-Chang
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.4
    • /
    • pp.111-115
    • /
    • 2014
  • Effect of dynamic electric fields on dielectric breakdown behavior in Cu damascene interconnects was investigated. Among the DC, unipolar, and bipolar pulse conditions, the longest dielectric lifetime is observed under the bipolar condition because backward Cu ion drift occurs when the direction of electric field is changed by 180 degrees and Cu contamination is prohibited as a results. Under the unipolar pulse condition, the dielectric lifetime increases as pulse frequency increases and it exceed the lifetime under DC condition. It suggests that the intrinsic breakdown of dielectrics significantly affect the dielectric breakdown in addition to Cu contamination. As the unipolar pulse width decreases, dielectric bond breakdown is more difficult to occur.

Harmonic and Torque Ripple Reduction of Electric Propulsion System using 12-Pulse Diode Rectifier by Auxiliary Supply (보조 전원을 이용한 12 펄스 다이오드 정류기를 사용하는 추진시스템의 고조파 및 토크 리플 저감)

  • Kim, Jong-Su;Seo, Dong-Hoan;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.1
    • /
    • pp.66-70
    • /
    • 2013
  • The input current of three phase rectifier which is mainly used in the propulsion system of the electric propulsion ship includes a variety of low order harmonics. To reduce these harmonics, the power conversion system, used in the large vessels which high power is required, is currently used the rectifiers of 12-pulse output, but it still has a problem that occurs $12{\pm}1$ harmonics. Also, in the case of the direct torque control technique which is widely used for the speed and torque control, the torque ripple is severe and the input current of motor has greatly included harmonics by the switching of the inverter. In order to reduce harmonics and improve the performance of torque control, this paper presents that the auxiliary supply assisted into the 12-pulse rectifier of the electric propulsion system using direct torque control technique. We confirm the validity of the proposed method through the simulation under the environment of a real vessel system.