• Title/Summary/Keyword: electric meter

Search Result 206, Processing Time 0.027 seconds

CONDUCTIVITIES OF SEA-BOTTOM SEDIMENTS

  • HoWoongShon
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.2
    • /
    • pp.79-87
    • /
    • 2003
  • An in-situ four-electrode contact resistivity probe system was designed, and field-tested in submarine sediments. Seismic survey was also performed to support and compare the results of electric survey. The probe was designed to be driven to selected depths below the seafloor using a Vibracore system. The four insulated electrodes were, spaced equidistant across the wedge, were extended beyond the probe tip to minimize effects of sediment disturbance by the wedge insertion. In-situ measurements of resistivity were recorded on board by precision electronic equipment consisting of signal generators and processors, and by temperature- monitoring systems. Overall limits of uncertainty at respective depths below the seafloor are up to ±10% of the measured values. Best estimates of conductivity are considered to be ±3 percent of the reported values. Resistivity measurements were made at six sites in carbonate sediments to a maximum depth of penetration of about 5 m. Average values of conductivity range between 0.88 and 1.21 mho/m. The results show the seabed is composed of alternating layers of relatively high-conductivity material (0.8 to 1.4 mho/m) in thicknesses of more or less one meter and layers about 30 cm thick having relatively low conductivities (0.4 to 0.8 mho/m).

  • PDF

Development of Operation Software for Electric Power Meter (전자식 전력량계 운용프로그램 개발)

  • Jang Moonjong;Kim S.I.;Go J.M.;Oh D.Y.;Yu I.H.;Lee J.K.
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2004.11a
    • /
    • pp.705-708
    • /
    • 2004
  • 한국전력공사는 검침업무의 복잡성을 단순화하고 유지보수에 따른 비용절감 등의 이유로 특정 제조회사의 통신방식이나 데이터구조 등에 구애받지 않도록 표준화된 전자식 전력량계의 통신프로토콜과 운용프로그램 개발을 수행하였다. 전자식 전력량계의 통신프로토콜을 통일하고 표준화된 검침용 운용프로그램을 사용함으로써 검침원에게는 다양한 검침용 운용프로그램 사용법을 익혀야하는 불편함을 없애고 각사별 검침용 장비의 유지관리에 따른 비용을 절감할 뿐만 아니라 저비용으로 보다 신뢰성 있는 원격검침 시스템 구축이 용이할 것으로 기대된다. 본 논문에서는 전자식 전력량계의 통신 프로토콜과 데이터구조, 운용프로그램 설계 및 구현에 대해 소개한다.

  • PDF

The Study on Optical Properties of Xenon ICP Lamp Dependently on Gas Pressure and Input Power (ICP 제논 램프의 가스 압력과 공급 전력에 따른 광학적 특성연구)

  • Choi, Gi-Seung;Lee, Seong-Jin;Lee, Jung-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1659-1660
    • /
    • 2006
  • After end of the 20th environmental problem was became issue. So about mercury free lighting sources are being studied very much. In this paper, a mercury and electrode free bulb was designed. in this bulb was injected mixed of Xe, Ne and Kr Gases. and then the bulb was discharged by 13.56MHz RF Power after spectrum, color coordinates and brightness were measured by spectrum meter CS-1000. Measured results were compared and analyzed, also analysis was able to do a characteristic of a gas defensive fight in proportion to a mixing ratio. Therefore the most of high brightness which was 4500cd/m2 was gained in 1:1 ratio of Xe:Ne at 60W input power.

  • PDF

Measurement of Gas Concentration and flow Rate Using Hot Wire (열선을 이용한 혼합기체의 농도와 유량의 측정)

  • Kim, Young-Han;Park, Jong-Jueng
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.5
    • /
    • pp.407-412
    • /
    • 2002
  • A measurement device for gas concentration and flow rate using hot wire is developed for the utilization in industrial applications. The device has two cells of measuring and reference, and a bridge circuit is installed to detect electric current through the hot wire in the cells. An amplification of the signal and conversion to digital output are conducted for the on-line measurement with a personal computer. The flow rate of air and carbon dioxide gas is separately measured for the performance examination of the device. Also, the concentration of air-carbon dioxide and carbon dioxide-argon mixtures is determined for the same evaluation. The outcome of the performance test indicates that the accuracy and stability of the device is satisfactory for the purpose of industrial applications.

A Study on the Evaluation of Cooling Demand using Cooling Gas Sales (냉방용 가스사용을 중심으로 추정한 냉방전력수요 평가)

  • KIM C.S.;Rhee C.H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.660-662
    • /
    • 2004
  • Cooling demand in Korea has increased constantly. Furthermore, an evaluation and savings of cooling demand has impacted on summer DSM and investment in Korea. Absorbed cooling system uses gas. It could achieve reductions in summer peak load and increase gas demand simultaneously. However its efficiency rate is lower than electric system. Gas cooling system uses separate meter. Therefore we could analyze monthly cooling demand and derive annual uses pattern. This paper analyzes demand pattern of gas cooling and its effects on electricity savings. Also this paper presents the course of policy in electricity sector on spreading of gas cooling measures.

  • PDF

A Remote Electric Meter Reading System based on Industrial x86 Android Platform (산업용 x86 안드로이드 플랫폼 기반의 원격 전기 검침 시스템)

  • Joo, Young Sun;Kim, Jong Bok;Jeong, Wooyoung;Jeon, Joongnam
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.11a
    • /
    • pp.3-4
    • /
    • 2011
  • 스마트폰을 필두로 태블릿 PC와 PMP 등 다수의 스마트 디바이스에 안드로이드가 적용되어 다양한 서비스를 제공하고 있다. 초기에는 ARM 계열의 디바이스에 주로 안드로이드가 탑재 되었으나 최근에는 ATOM CPU 기반의 넷북 등 x86 기반의 다양한 디바이스에도 탑재가 이루어지고 있어 탑재 가능한 하드웨어 범주가 점차 확장되고 있으며, 산업용 디바이스 또한 탑재에 대한 관심이 크게 증가하고 있는 추세이다. 본 논문은 무선 네트워크를 적용한 x86 기반의 산업용 컴퓨터에 안드로이드를 탑재하여 원격 전기 검침 서비스를 제공하는 시스템을 구현한다.

A Study on the development and calibration method of a modular internal resistance meter to improve the safety of reusable batteries

  • Mi-Jin Choi;Sang-Bum Kim
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.3
    • /
    • pp.228-235
    • /
    • 2024
  • Battery use is increasing worldwide to achieve carbon neutrality and improve energy efficiency, but batteries are a finite resource and their application is determined by capacity and specifications. Battery performance deteriorates as the number of uses increases. A certain level of battery performance degradation has become an issue in the field of reuse and recycling, and various studies are being conducted on reuse to solve power shortages. Waste batteries from electric vehicles are suitable for building ESS based on reusable batteries, and for stable use, technical skills are needed to accurately predict battery life and determine status information. Predicting battery life and determining status information are difficult due to non-linearity due to internal structure or chemical changes. In this paper, we manufactured a modular internal resistance measuring device and compared the measured values with Hioki equipment to minimize the error rate through a correction method. As a result of testing Hioki equipment and modular measuring instruments to ensure efficiency and safety based on reusable batteries, an accuracy of over 95% was confirmed.

Development of Magnetic Sensor for Live Line Detector of the Underground Cable (지중케이블 활선검출기를 위한 자장 센서 개발)

  • Kim, Ki-Joon;Oh, Yong-Cheul;Lee, Kyeong-Seob;Jung, Han-Seok;Kim, Tag-Yong;Choi, Mi-Hui;Soung, Min-Yeong;Shin, Cheol-Gi;Kim, Jin-Sa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.2
    • /
    • pp.166-171
    • /
    • 2011
  • We use the electrical energy and it is essential energy in modern life, but we lay cable underground due to the issue for environment and safety. Safety for worker is still insufficient for the development of safety equipment and related research has been focused on the cable lifetime diagnosis at underground cable work. I have to develop live line detector around the magnetic field were investigated at underground cable. In this paper, we were investigated by variation of coil turns and load due to detection of magnetic field at lines around. And detected value of developing products compared with measured value of milli-gauss meter. As a result, the value of the number of coil turns was found to be proportional to the measured value. But turn-numbers increase showed that the weak noise. I could be confirmed that sensor showed the optimum value from 4,000 to 5,0000.

Effect of Carbon Fiber Layer on Electrochemical Properties of Activated Carbon Electrode

  • Jong kyu Back;Jihyeon Ryu;Yong-Ho Park;Ick-Jun Kim;Sunhye Yang
    • Journal of Electrochemical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.184-193
    • /
    • 2023
  • This study investigates the effects of a carbon fiber layer formed on the surface of an etched aluminum current collector on the electrochemical properties of the activated carbon electrodes for an electric double layer capacitor. A particle size analyzer, field-emission SEM, and nitrogen adsorption/desorption isotherm analyzer are employed to analyze the structure of the carbon fiber layer. The electric and electrochemical properties of the activated carbon electrodes using a carbon fiber layer are evaluated using an electrode resistance meter and a charge-discharge tester, respectively. To uniformly coat the surface with carbon fiber, we applied a planetary mill process, adjusted the particle size, and prepared the carbon paste by dispersing in a binder. Subsequently, the carbon paste was coated on the surface of the etched aluminum current collector to form the carbon under layer, after which an activated carbon slurry was coated to form the electrodes. Based on the results, the interface resistance of the EDLC cell made of the current collector with the carbon fiber layer was reduced compared to the cell using the pristine current collector. The interfacial resistance decreased from 0.0143 Ω·cm2 to a maximum of 0.0077 Ω·cm2. And degradation reactions of the activated carbon electrodes are suppressed in the 3.3 V floating test. We infer that it is because the improved electric network of the carbon fiber layer coated on the current collector surface enhanced the electron collection and interfacial diffusion while protecting the surface of the cathode etched aluminum; thereby suppressing the formation of Al-F compounds.

Design of New Smart Switch with Remote Power Control and Standby Power Management Function (원격 전력제어 및 대기전력 관리 기능을 갖는 새로운 스마트 스위치 설계)

  • Lee, Yong-An;Kim, Kang-Chul;Han, Seok-Bung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.10
    • /
    • pp.2343-2350
    • /
    • 2010
  • In this paper, new smart switch that can monitor and control the power consumption and standby power in real-time by implementing an embedded web-server is proposed. The proposed switch can perform the following functions: measuring the electric power like commercial smart meter product, monitoring the power consumption in real-time in distant places through wire and wireless devices, and finally controlling ON/OFF of each switch. In addition, it also contains auto power-shutoff functions for standy power, overvoltage and overcurrent just like existing power-saving outlet and mulitap. Finally, the proposed smart switch has lower hardware and power consumption than the existing products and can be commercialized as a small-sized product by using exclusive embedded web-server of its own, rather than using PC for monitoring and remote control.