• 제목/요약/키워드: electric constant

검색결과 1,069건 처리시간 0.025초

팬타그래프 전압제약조건을 고려한 AT급전계통 해석 (Analysis Of AT Feeding Systems Considering The Voltage Constraint Conditions Of The Pantagraph)

  • 문영현;김백
    • 한국철도학회논문집
    • /
    • 제9권6호
    • /
    • pp.652-656
    • /
    • 2006
  • Constant load model is widely used for an electric train to perform the static analysis of AT (Auto Transformer) feeding systems. In this model, the train will be considered as a constant load model when it drives or as a constant source model when it applies regenerative brake. However there must be some constraints imposed on the pantagraph voltage in actual operations. These constraints are established for the reason of protecting the feeding facilities from excessive rise of regenerative braking voltage or guaranteeing the minimum traction power of train. In normal operating situation, the pantagraph voltage of the train should be maintained within these limits. Keeping these facts in minds, we suggest new methods or analyzing AT feeding systems using the constant power models with the conditions of voltage constraints. The simulation results from a sample system using the proposed method illustrate both the states of system variables and the supply-demand relation of power among the trains and the systems very clearly, so it is believed that the proposed method yields more accurate results than conventional methods do. The proposed methods are believed to contribute to the assessment of TCR-TSC for compensating reactive powers too.

전기자동차 충전을 위한 2상 구동 시스템에 관한 연구 (2-phase drive for electric vehicle charging)

  • 전성즙
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1-2
    • /
    • 2015
  • In this paper, a 2-phase feeder system for wireless vehicle charging is investigated, which generates moving magnetic field with nearly constant magnitude using 2-phase currents. A moving field is very useful to magnetizing pickups mounted on underneath of electric vehicles.

  • PDF

항공관제용 정전류조정(CCR) 인버터 시스템의 개발 (A Constant Current Regulated Inverter System for Lighting and Beaconing of Aerodromes)

  • 손진근;박종찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.141-146
    • /
    • 2006
  • According as level of industry develops day after day, electricity load system of industry requires high level control, effectiveness and high efficiency. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting and electric heating system. Therefore, in this paper proposed an inverter systems with constant current regulation and power factor correction (PFC) circuit for Lighting and Beaconing of Aerodromes. The effectiveness of the proposed system confirmed through experimental results of CCR.

  • PDF

(Pb,Ba)(Zr,Ti)$O_3$계 세라믹스의 )$Y_2O_3$첨가에 따른 유전 및 전왜 특성 (Dielectric and electrostrictive properties of (Pb,Ba)(Zr,Ti))$O_3$ ceramics with $Y_2O_3$addition)

  • 김규수;윤광희;윤현상;홍재일;유주현;박창엽
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권6호
    • /
    • pp.551-557
    • /
    • 1996
  • To decrease the hysteresis of electric field induced strain, $Y_{2}$ $O_{3}$ dopant of which amount is 0-0.8wt% was added to the (P $b_{0.73}$B $a_{0.27}$)(Z $r_{0}$ 75/ $Ti_{0.25}$) $O_{3}$ ceramics. Electromechanical coupling coefficients of the specimen with 0.1 Wt% $Y_{2}$ $O_{3}$ were $k_{p}$=26.9% and $k_{31}$ =20.4%, which exhibited the maximum value at the constant bias electric field of 10 kV/cm. At the same $Y_{2}$ $O_{3}$ addition amount, electric field piezoelectric constant ( $d_{3l}$) and strain(.DELTA.l/l) showed the maximum values of 139.6*10$^{-12}$ [C/N] and 126*10$^{-6}$ .DELTA. l/l respectively at 10 kV/cm electric field. And the hysteresis of strain showed the minimum value of 17.5%. So, we propose that it is possible to apply PBZT system with $Y_{2}$ $O_{3}$ dopant to the electrostrictive actuator.r.r.

  • PDF

Pyroelectric and pyromagnetic effects on behavior of magneto-electro-elastic plate

  • Kondaiah, P.;Shankar, K.;Ganesan, N.
    • Coupled systems mechanics
    • /
    • 제2권1호
    • /
    • pp.1-22
    • /
    • 2013
  • Under thermal environment, Magneto-Electro-Elastic (MEE) material exhibits pyroelectric and pyromagnetic effects which can be used for enhancing the performance of MEE sensors. Recently studies have been published on material constants such as pyroelectric constant and pyromagnetic constant for magneto-electro-thermo-elastic smart composite. Hence, the main aim of this paper is to study the pyroelectric and pyromagnetic effects on behavior of MEE plate under different boundary conditions subjected to uniform temperature. A numerical study is carried out using eight noded brick finite element under uniform temperature rise of 100 K. The study focused on the pyroelectric and pyromagnetic effects on system parameters like displacements, thermal stresses, electric potential, magnetic potential, electric displacements and magnetic flux densities. It is found that, there is a significant increase in electric potential due to the pyroelectric and pyromagnetic effects. These effects are visible on electric and magnetic potentials when CFFC and FCFC boundary conditions are applied. Additionally, the pyroelectric and pyromagnetic effects at free edge is dominant (nearly thrice the value in CFFC in comparison with FCFC) than at middle of the plate. This study is a significant contribution to sensor applications.

An Analytical Solution for Voltage Stability Studies Incorporating Wind Power

  • Lin, Yu-Zhang;Shi, Li-Bao;Yao, Liang-Zhong;Ni, Yi-Xin;Qin, Shi-Yao;Wang, Rui-Ming;Zhang, Jin-Ping
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.865-876
    • /
    • 2015
  • Voltage stability is one of the most critical security issues which has not yet been well resolved to date. In this paper, an analytical method called PQ plane analysis with consideration of the reactive power capability of wind turbine generator and the wake effect of wind farm is proposed for voltage stability study. Two voltage stability indices based on the proposed PQ plane analysis method incorporating the uncertainties of load-increasing direction and wind generation are designed and implemented. Cases studies are conducted to investigate the impacts of wind power incorporation with different control modes. Simulation results demonstrate that the constant voltage control based on reactive power capability significantly enhances voltage stability in comparison of the conventional constant power factor control. Some meaningful conclusions are obtained.

저온소결 (K0.5Na0.5)NbO3 세라믹스의 분극전계에 따른 압전 및 유전특성 (Piezoelectric and Dielectric Properties of Low Temperature Sintering (K0.5Na0.5)NbO3 Ceramics with the Variation of Poling Electric Field)

  • 이일하;류주현;정영호
    • 한국전기전자재료학회논문지
    • /
    • 제21권11호
    • /
    • pp.1000-1004
    • /
    • 2008
  • In this paper, the influences of poling electric field on piezoelectric properties of $0.95(K_{0.5}Na_{0.5})NbO_3$-$0.05Li(Sb_{0.8}Nb_{0.2})O_3$ (abbreviated as KNN-LSN) ceramics were investigated. The specimens was sintered at sintering temperature of $1050^{\circ}C$. They showed orthorhombic phase structure without secondary phase. Electromechanical coupling factor (kp), dielectric and piezoelectric constant($d_{33}$) increased with poling electric field. However, mechanical quality factor (Qm) decreased. Take into account of poling conditions and piezoelectric properties of KNN-LSN ceramics, the optimum poling condition for KNN-LSN ceramics was poling electric field of 4.5 kV/mm. At the time, kp of 0.458, Qm of 43.97, $d_{33}$ of 278 pC/N, and dielectric constant of 1079 were shown, respectively.

Pulse Density Modulated Zero Voltage Soft-Switching High-Frequency Inverter with Single Switch for Xenon Gas Dielectric Barrier Discharge Lamp Dimming

  • Sugimura, Hisayuki;Suh, Ki-Young;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.391-394
    • /
    • 2006
  • This paper presents soft switching zero voltage switching high frequency inverter for rare gas fluorescent lamp using dielectric-barrier discharge phenomenon. The simple high-frequency inverter can completely achieve stable zero voltage soft switching (ZVS) commutation for wide its output power regulation ranges and load variations under its constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operating principle is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZVS operation commutation, together with its output effective power regulation characteristics-based on the high frequency PDM strategy. The experimental operating performances of this high frequency Inverter are illustrated as compared with computer simulation results and experimental ones. Its light dimming characteristics due to power regulation scheme are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliance implemented here is proven from the practical point of view.

  • PDF

Comparative Study of Flux Regulation Methods for Hybrid Permanent Magnet Axial Field Flux-switching Memory Machines

  • Yang, Gongde;Fu, Xinghe;Lin, Mingyao;Li, Nian;Li, Hao
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.158-167
    • /
    • 2019
  • This research comparatively studies three kinds of flux regulation methods, namely, stored capacitor discharge pulse (SCDP), constant current source pulse (CCSP), and quantitative flux regulation pulse (QFRP), which are used for hybrid permanent magnet (PM) axial field flux-switching memory machines (HPM-AFFSMMs). Through an analysis of the operation principle and the series hybrid PM flux regulation mechanism of the objective machine, the circuit topologies and flux regulation process of these flux regulation methods are addressed in detail. On the basis of a simulation, the flux regulation characteristics of the researched machine during the magnetization and demagnetization processes are comparatively evaluated. Then, machine performance, including back EMF, direct and quadrature axis inductances, and magnetization and demagnetization characteristics, is quantitatively investigated. Results show that the QFRP enables the HPM-AFFSMM to achieve a less harmonic component of back EMF by approximately 7.28% and 7.97% at the magnetization and demagnetization states, respectively, and a more complete magnetization process than the SCDP and CCSP.

수변전설비에서 접점 불량에 따른 열 및 전계 분포 해석 (The Analysis of Temperature and Electric Field due to Contact Failure in Power Substation)

  • 김기준
    • 한국전기전자재료학회논문지
    • /
    • 제29권5호
    • /
    • pp.307-311
    • /
    • 2016
  • Although there are existing Residual Current Protective Device (RCD) including detect electric leakage and elements such as short circuit and surge, the occurrence of incidents caused by electric faults, including fire, are still constant. The purpose of this study is to analyze the causes of accidents through the electric field distribution in the interpretation of the fault contact breaker. Simulation results by the arc fault has shown the convergence of temperature and electric field to the defect. Through their simulation results, the main cause of erosion phenomena in circuit breaker bar is the electric arc by concentration of electric field not due to dissolve by temperature.