• Title/Summary/Keyword: efficiency test

Search Result 5,992, Processing Time 0.033 seconds

An Experimental Study on Torque Characteristics and Efficiency of Hydraulic Couplings (유체커플링의 토오크 특성과 효율에 관한 실험적 연구)

  • 박용호;염만오
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.5
    • /
    • pp.46-55
    • /
    • 1994
  • The purpose of this research is to construct experimental test set-up and to establish a series of performance test program for the domestically developed hydraulic couplings, and to provide a software to store and utilize these experimental data which can be used to improve the performance of the hydraulic coupling and solve the job problems confronted during operation. The performance test consists of measurement of torque, rpm and efficiency of the hydraulic coupling for three different amounts of working fluid with various loads to the output shaft, and investigating the torque, rpm and efficiency characteristics with respect to these parameters. The results of this study can contribute to the development of variable speed hydraulic coupling and torque converter pursued by the domestic industry.

  • PDF

Performance Characteristics of Micro Propeller Turbine (마이크로 프로펠러 수차의 성능 특성)

  • Kim, Byung-Kon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.3
    • /
    • pp.25-32
    • /
    • 2014
  • The main objective of this study is to validate the performance characteristics of newly developed micro propeller turbine based on experimental model test. For this purpose, Measurements of efficiency and cavitation tests with variations on the guide vane opening, blade rotational speed, head and load are carried out according to the IEC standard for model testing. From the tests and scale up calculation, the maximum prototype and model efficiency of the runner blade reaches as high as 90.87 % and 90.27 % respectively. Test results show that good cavitation behavior is covered in the range of output 50kW and 100 kW.

Decontamination of Simulated Test Piece by Dry Ice Pellet Blasting (드라이아이스 펠렛 분사에 의한 모의 시편의 제염)

  • Shin Jin-Myeong;Park Jang-Jin;Yang Myung-Seung
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.2
    • /
    • pp.30-36
    • /
    • 2004
  • Dry decontamination technique is required for maintaining nuclear material handling equipment contaminated with highly radioactive material in a hot cell. In order to determine the optimum blasting conditions of dry ice pellet blasting device, the basic experiments have been conducted on the simulated test specimens of four types of metals. The removal efficiency of test piece was evaluated by the XRF analysis and the change of the surface condition before and after blasting. The removal efficiency of cesium on loose contamination was 100% under blasting pressure; 3 kg/$cm^2$, blasting distance; 10 cm, blasting time: 10 sec. In case of fixed contamination, the removal efficiency of cesium was almost 96% under blasting pressure; 4kg/$cm^2$, blasting distance; 10 cm, blasting time; 30 sec.

A Study of a Generator Efficient Testing Method that Incorporates Tidal Limitations (조력발전소 조위 제약사항을 고려한 발전기 효율시험에 관한 연구)

  • Kim, Hyun-Han;Jun, Jung-Pou;Kim, Kwang-Ho
    • Journal of Industrial Technology
    • /
    • v.33 no.A
    • /
    • pp.23-30
    • /
    • 2013
  • Tidal power generation is to produce electrical energy from fluctuations of the ebb and flow in a constructed embankment. More specifically, the sinusoidal variations of tidal flow, along with the periodicity and changes in the height of waves over time make the tidal power generation possible at a certain tidal level. This paper proposes a more practical efficiency test method for tidal power plant generator that utilizes the axis torque changing values rather than the retardation method which is commonly used. The proposed method was compared with the conventional method and the test result shows that proposed method provides a similar accuracy with the conventional retardation method and a better efficiency.

  • PDF

A Study on the Evaluation of Turbine Efficiency through the Performance Test of New Power Plant (신규 화력발전소의 성능 시험을 통한 터빈 효율의 평가에 관한 연구)

  • Kweon, Y.S.;Chung, H.T.;Jung, Y.B.
    • Journal of Power System Engineering
    • /
    • v.5 no.1
    • /
    • pp.11-20
    • /
    • 2001
  • Super-critical type steam power plant, which operates with steam pressure above the super-critical point, has a good reputation recently and is adopted as a new standard of the Korean Electric Power Corporation. The reason for the good reputation lies in it's superior power efficiency. However, the field data of the new power plant for the verification of it's performance are still insufficient, and more empirical data are needed to acquire technologies on the effective operation of it. In this study, the authors analyzed the field test data on power efficiencies got in a super-critical type steam power plant, and evaluated the excellency of the new plant by comparing the efficiency data with the one got in a conventional sub-critical type steam power plant.

  • PDF

A Study on the Performance Test of Axial-flow Cyclone Separator (축상유입식 사이클론 집진기 성능시험에 관한 연구)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.1
    • /
    • pp.101-106
    • /
    • 2020
  • Along with dust collection efficiency, pressure loss is a very important cyclone operation factor. A severe rise in pressure loss causes the problem of cost. To solve the problem, the method connecting axial-vane type cyclones in parallel is suggested recently. The axial vane type cyclone dust collector applied in this study is a small portable type. Multiple cyclones are installed in a round type. The basic performance test on the axial vane type cyclone dust collector was conducted. As a result, the cut size reduced along with a rise in the wind velocity of the cyclone dust collector inlet. According to the test on dust collection efficiency, the effect of dust collection began to appear in the range of 3㎛ and dust collection efficiency was greatly improved at 5 ㎛. The noise of the cyclone dust collector well met the fan sound power level of KSB 6361.

Experimental Study on Efficiency of Floating Vertical Axis Wind Turbine with Variable-Pitch (부유식 가변 피치형 수직축 풍력발전기의 발전효율에 관한 실험 연구)

  • Kim, Jae-Heui;Jo, Hyo-Jae;Hwang, Jae-Hyuk;Jang, Min-Suk;Lee, Byeong-Seong
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.202-207
    • /
    • 2018
  • This paper presents the efficiency of a floating vertical axis wind turbine with variable-pitch. A model was designed to use the lift force and drag force for blades with various pitch angles. The blade's pitch angle is controlled by the stopper. To validate the efficiency of the wind turbine discussed in this paper, a model test was carried out through a single model efficiency experiment and wave tank experiment. The parameters of the single model efficiency experiment were the wind speed, electronic load, and pitch angle. The wave tank experiment was performed using the most efficient pitch angle from the results of the single model efficiency experiment. According to the results of the wave tank experiment, the surge and pitch motion of a structure slightly affect the efficiency of a wind turbine, but the heave motion has a large effect because the heights of the wind turbine and wind generator are almost the same.

Evaluation of the KASI Detector Performance Test System Using an Andor iKon M CCD Camera

  • Yu, Young Sam;Kim, Jinsol;Park, Chan;Jeong, Woong-Seob;Kim, Minjin;Choi, Seonghwan;Park, Sung-Joon
    • Journal of Astronomy and Space Sciences
    • /
    • v.35 no.3
    • /
    • pp.201-210
    • /
    • 2018
  • The characterization of detectors installed in space- and ground-based instruments is important to evaluate the system performance. We report the development of a detector performance test system for astronomical applications using the Andor iKon M CCD camera. The performance test system consists of a light source, monochromator, integrating sphere, and power meters. We adopted the Czerny-Tuner monochromator with three ruled gratings and one mirror, which covers a spectral range of 200-9,000 nm with a spectral resolution of ~1 nm in the visible region. Various detector characteristics, such as the quantum efficiency, sensitivity, and noise, can be measured in wide wavelength ranges from the visible to mid-infrared regions. We evaluated the Korea Astronomy and Space Science Institute (KASI) detector performance test system by using the performance verification of the Andor iKon-M CCD camera. The test procedure includes measurements of the conversion gain ($2.86e^-/ADU$), full well capacity ($130K\;e^-$), nonlinearity, and pixel defects. We also estimated the read noise, dark current, and quantum efficiency as a function of the temperature. The lowest measured read noise is $12e^-$. The dark current at 223 K was determined to be $7e^-/s/pix$ and its doubling temperature is $5.3^{\circ}C{\pm}0.2^{\circ}C$ at an activation energy of 0.6 eV. The maximum quantum efficiency at 223 K was estimated to be $93%{\pm}2%$. We proved that the quantum efficiency is sensitive to the operating temperature. It varies up to 5 % in the visible region, while the variation increases to 30 % in the near-infrared region. Based on the comparison of our results with the test report by the vendor, we conclude that our performance test results are consistent with those from the vendor considering the test environment. We also confirmed that the KASI detector performance test system is reliable and our measurement method and analysis are accurate.

A Study on a Simple Efficiency Estimation of Small DC Motor (소형 직류모터의 간략한 효율예측에 관한 연구)

  • Won, Sung Hong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.3
    • /
    • pp.143-148
    • /
    • 2014
  • This paper proposes a novel efficiency measurement method without dynamometer. In case of small motor, the measurement of efficiency is not easy because the percentage of mechanical loss is comparably huge and the mechanical loss is not easy to be measured. In this paper, the authors proposes a method which can measure the efficiency with two test motors. This method can be useful to engineers who study small electrical motors.

The Status of Maintenance of Exhaust Fans and Bag filters in Melting Processes in a foundry industrial complex (주물 공단 용해공정의 송풍기 및 백필터 관리 실태)

  • Kim, Tae Hyeung;Ha, Hyun Chul;Jeoung, Chun Hwa;Seo, Jeoung Yoon;Piao, Cheng Xu;Yang, Jun Ho;Li, Xiaoyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.3
    • /
    • pp.212-223
    • /
    • 2007
  • 18 Local exhaust ventilation systems in 10 melting companies located in an industrial complex were tested to know the status of maintenance. Test items were fan flowrates, fan static pressures, rotational speeds and differential pressures of bag filters. Only 22% of the tested fans has more than 80% flowrate efficiency. 44% of the fans has lower than 60% efficiency. The performance of the fans are not in a good status. For the fans with lower than 60% efficiency, the analysis shows that the lower flowrate might be caused by the degradation of fan performance. On the other hand, for the fan s with higher than 60% efficiency, the main cause of flowrate reduction might be too much pressure losses due to clogging of filter bags. The degradation of fans usually lead the reduction of hood capture efficiency, resulting in the increase of contaminant concentrations in workplace. To keep fans in good status, self inspections should be periodically conducted. This inspection should include the measurements of flowrate and pressures. The most important thing to be performed is the initial test of local exhaust ventilation system because the initial test data should be used to know the level of system degradation.