• Title/Summary/Keyword: effective equivalent dose

Search Result 101, Processing Time 0.02 seconds

Status of Radiation Dose and Radioactive Contamination due to the Fukushima Accident

  • Baba, Mamoru
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.133-140
    • /
    • 2016
  • Backgrounds: The accident at Fukushima Daiichi Nuclear Power Plant (NPP), March 2011, caused serious radioactive contamination over wide area in east Japan. Therefore, it is important to know the effect of the accident and the status of NPP. Materials and Methods: This paper provides a review on the status of radiation dose and radioactive contamination caused by the accident on the basis of publicized information. Results and Discussion: Monitoring of radiation dose and exposure dose of residents has been conducted extensively by the governments and various organizations. The effective dose of general residents due to the accident proved to be less than a mSv both for external and internal dose. The equivalent committed dose of thyroid was evaluated to be a few mSv in mean value and less than 50 mSv even for children. Monitoring of radioactivity concentration has been carried out on food ingredients, milk and tap water, and actual meal. These studies indicated the percentage of foods above the regulation standard was over 10% in 2011 but decreasing steadily with time. The internal dose due to foods proved to be tens of ${\mu}Sv$ and much less than that due to natural $^{40}K$ even in the Fukushima area and decreasing steadily, although high level concentration is still observed in wild plants, wild mushrooms, animals and some kind of fishes. Conclusion: According to extensive studies, not only the effect of the accident but also the pathway and countermeasures against radioactive contamination have been revealed, and they are applied very effectively for restoration of environment and reconstruction of the area.

Characteristic Evaluation of Exposed Dose with NORM added Consumer Product based on ICRP Reference Phantom (ICRP 기준팬텀 기반의 천연방사성핵종이 포함된 가공제품 사용으로 인한 피폭선량 특성 평가)

  • Yoo, Do Hyeon;Lee, Hyun Cheol;Shin, Wook-Geun;Choi, Hyun Joon;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.159-167
    • /
    • 2014
  • In Korea, July 2012, the law as called 'Act on Safety Control of Radioactive Rays Around Living Environment' was implemented to control the consumer product containing Naturally Occurring Radioactive Material (NORM), but, there are no appropriate database and effective dose calculation system. The aim of this study was to develop evaluation technique of the exposure dose with the use of the consumer products containing NORM and to understand the characteristics of the exposed dose according to the radiation type and energy. For the evaluate of exposure dose, the ICRP reference phantom was simulated by the MCNPX code based on Monte Carlo method, and the minimum, medium, maximum energy of alphas, betas, gammas from the representative NORM of Uranium decay series were used as the source term in the simulation. The annual effective doses were calculated by the exposure scenario of the consumer product usage time and position. Short range of the alpha and beta rays are mostly delivered the dose to the skin. On the other hand, the gamma rays mostly delivered the similar dose to all of the organs. The results of the annual effective dose with $1Bq{\cdot}g^{-1}$ radioactive stone-bed and 10% radioactive concentration were employed with the usage time of 7 hours 50 minute per day, the maximum annual effective dose of alphas, betas, gammas were calculated 0.0222, 0.0836, $0.0101mSv{\cdot}y^{-1}$, respectively.

Assessment of Effective Doses in the Radiation Field of Contaminated Ground Surface by Monte Carlo Simulation (몬테칼로 시뮬레이션에 의한 지표면 오염 방사선장에서의 유효선량 평가)

  • Chang, Jai-Kwon;Lee, Jai-Ki;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.4
    • /
    • pp.205-213
    • /
    • 1999
  • Effective dose conversion coefficients from unit activity radionuclides contaminated on the ground surface were calculated by using MCNP4A rode and male/female anthropomorphic phantoms. The simulation calculations were made for 19 energy points in the range of 40 keV to 10 MeV. The effective doses E resulting from unit source intensity for different energy were compared to the effective dose equivalent $H_E$ of previous studies. Our E values are lower by 30% at low energy than the $H_E$ values given in the Federal Guidance Report of USEPA. The effective dose response functions derived by polynomial fitting of the energy-effective dose relationship are as follows: $f({\varepsilon})[fSv\;m^2]=\;0.0634\;+\;0.727{\varepsilon}-0.0520{\varepsilon}^2+0.00247{\varepsilon}^3,\;where\;{\varepsilon}$ is the gamma energy in MeV. Using the response function and the radionuclide decay data given in ICRP 38, the effective dose conversion coefficients for unit activity contamination on the ground surface were calculated with addition of the skin dose contribution of beta particles determined by use of the DOSEFACTOR code. The conversion coefficients for 90 important radionuclides were evaluated and tabulated. Comparison with the existing data showed that a significant underestimates could be resulted when the old conversion coefficients were used, especially for the nuclides emitting low energy photons or high energy beta particles.

  • PDF

Radiation Exposure Dose of Handlers Using 18F-FDG in Small Animal Image Acquisition Experiments

  • Ik Soo Kim;Sun Young Yoon;Hwa Yeon Yeo
    • Journal of Radiation Industry
    • /
    • v.17 no.3
    • /
    • pp.233-238
    • /
    • 2023
  • This study was conducted to confirm the safety of the operator's radiation exposure in the micro PET-CT image acquisition experiment using the 18F-FDG. The usage of 18F-FDG and the exposure dose of handlers were measured at University B in Metropolitan City A, which uses 18F-FDG for micro PET-CT image acquisition. As a result of the measurement, the exposure dose is far below the effective dose limit of radiation workers, 50 mSv per year, and the equivalent dose limit of 500 mSv per year for hands, feet, and skin. has been measured Since these exposure doses can be further increased according to the number of times of use of 18F-FDG, it is judged that the exposure dose compared to the handling amount of 18F-FDG shown in this study can be used as reference data. In addition, as changed environments such as the use of materials other than unopened RI are occurring in education and research environments, such as the use of 18F-FDG at University B, radiation exposure with more interest in safety management by checking the factors of radiation exposure of the handler concerned We will always do our best to reduce it.

DEVELOPMENT OF POINT KERNEL SHIELDING ANALYSIS COMPUTER PROGRAM IMPLEMENTING RECENT NUCLEAR DATA AND GRAPHIC USER INTERFACES

  • Kang, Sang-Ho;Lee, Seung-Gi;Chung, Chan-Young;Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.215-224
    • /
    • 2001
  • In order to comply with revised national regulationson radiological protection and to implement recent nuclear data and dose conversion factors, KOPEC developed a new point kernel gamma and beta ray shielding analysis computer program. This new code, named VisualShield, adopted mass attenuation coefficient and buildup factors from recent ANSI/ANS standards and flux-to-dose conversion factors from the International Commission on Radiological Protection (ICRP) Publication 74 for estimation of effective/equivalent dose recommended in ICRP 60. VisualShieid utilizes graphical user interfaces and 3-D visualization of the geometric configuration for preparing input data sets and analyzing results, which leads users to error free processing with visual effects. Code validation and data analysis were performed by comparing the results of various calculations to the data outputs of previous programs such as MCNP 4B, ISOSHLD-II, QAD-CGGP, etc.

  • PDF

Investigation of organ dose difference of age phantoms for medical X-ray examinations (X선 촬영 시 연령별 장기선량 차이 연구)

  • Park, Sang-Hyun;Lee, Choon-Sik;Kim, Woo-Ran;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.1
    • /
    • pp.35-42
    • /
    • 2003
  • Methodology for calculating the organ equivalent doses and the effective doses of pediatric and adult patients undergoing medical X-ray examinations were established. The MIRD-type mathematical phantoms of 4 age groups were constructed with addition of the esophagus to the same phantoms. Two typical examination procedures, chest PA and abdomen AP, were simulated for the pediatric patients as well as the adult as illustrative examples. The results confirmed that patients pick up approximate 0.03 mSv of effective dose from a single chest PA examination, and 0.4 to 1.7 mSv from an abdomen AP examination depending on the ages. For dose calculations where irradiation is made with a limited field, the details of the position, size and shape of the organs and the organ depth from the entrance surface considerably affect the resulting doses. Therefore, it is important to optimize radiation protection by control of X-ray properties and beam examination field. The calculation result, provided in this study, can be used to implement optimization for medical radiation protection.

A Study on the Removal Characteristics of Microcystin in the Water Treatement Plant by Ozonation (오존산화에 의한 정수장의 Microcystin제거 특성에 관한 연구)

  • 김민규;권재현;조영하;이진애;권오섭
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.74-83
    • /
    • 2003
  • Microcystin, stable compounds with circular heptapeptides, is presented inside cyanobacterial cell. So far, over 30 types have been known to exist and microcystin-LR, RR among them are the most potent toxin compound. By this reason, a strong oxidant, ozone was used in this study to remove the microcystins produced by cyanobacteria. Removal efficiency of microcystin at M water treatment plant was also evaluated. Microcystin concentration was determined by protein phosphatase inhibition assay. The results showed that dissolved microcystin in raw water detected in the range of 0.011-0.028 ㎍ Microcystin-RR equivalent/l. Above 98% of microcystin was removed through overall treatment system. Therefore, the water treatability of M treatment plant seemed to be excellent. Removal efficiency of microcystin according to unit process varied as characteristics of raw water such as DOC, UV/sub 254/ and turbidity. Removal efficiency of microcystin by ozonation was investigated in laboratory according to contact time and ozone dose. Dissolved microcystin was increased by twice fold according to ozone contact time, but increased by fifth fold according to ozone dose. So, changing of ozone dose more affected microcystin release than changing of ozone contact time. Behavior of microcystin by ozonation was similar to that of DOC, and residual ozone concentration gave influence to removal ratio of microcystin. In conclusion, single ozone treatment wasn't effective on microcystin removal in case of water containing a lot of cells. Therefore, it's more effective to use ozonation process after the removal of cyanobacterial cells in advance.

Safety classification for frequently-used herbal medicines inducing toxic metabolites (독성대사체를 생성하는 다빈도사용 한약재의 안전성등급화 - 천궁, 당귀, 감초, 숙지황을 중심으로 -)

  • Park, Yeong-Chul;Lee, Sundong
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.19 no.2
    • /
    • pp.123-133
    • /
    • 2015
  • The new formular for herbal medicine-safety classification in terms of evidence-based medicine was developed and applied to evaluate various herbal medicines in the previous study. This study is aimed to evaluate the frequently-used herbal medicines inducing toxic metabolites or reactive intermediates(RI), such as Ligusticum wallichii Franch, Angelica sinensis, Glycyrrhizae Radix, Rehmanniae Radix, based on 6 safety grades calculated from human equivalent dose(HED)-based MOS(margin of safety). HED-based MOS can be explained as the ratio of theoretical ALD(approximate lethal dose) of human as $LD_1$(lethal dose of 1%)/ clinical maximum dose as $ED_{99}$(Effective dose of 99%). The herbal medicine showing the ratio less than 1 belongs to Class 1, but the herbal medicine showing the ratio more than 500 belongs to Class 6 with the lowest toxicity. As a result, they were evaluated as class 2 for Angelica sinensis and Glycyrrhizae Radix, class 3 for Ligusticum wallichii Franch and Rehmanniae Radix. These resultant grades for 4 herbal medicines were lower than the grade expected under consideration that these herbal medicines are used very frequently in oriental clinics. These low grades would be due to their ingredients which is biotransformed to toxic metabolites.

History of the Photon Beam Dose Calculation Algorithm in Radiation Treatment Planning System

  • Kim, Dong Wook;Park, Kwangwoo;Kim, Hojin;Kim, Jinsung
    • Progress in Medical Physics
    • /
    • v.31 no.3
    • /
    • pp.54-62
    • /
    • 2020
  • Dose calculation algorithms play an important role in radiation therapy and are even the basis for optimizing treatment plans, an important feature in the development of complex treatment technologies such as intensity-modulated radiation therapy. We reviewed the past and current status of dose calculation algorithms used in the treatment planning system for radiation therapy. The radiation-calculating dose calculation algorithm can be broadly classified into three main groups based on the mechanisms used: (1) factor-based, (2) model-based, and (3) principle-based. Factor-based algorithms are a type of empirical dose calculation that interpolates or extrapolates the dose in some basic measurements. Model-based algorithms, represented by the pencil beam convolution, analytical anisotropic, and collapse cone convolution algorithms, use a simplified physical process by using a convolution equation that convolutes the primary photon energy fluence with a kernel. Model-based algorithms allowing side scattering when beams are transmitted to the heterogeneous media provide more precise dose calculation results than correction-based algorithms. Principle-based algorithms, represented by Monte Carlo dose calculations, simulate all real physical processes involving beam particles during transportation; therefore, dose calculations are accurate but time consuming. For approximately 70 years, through the development of dose calculation algorithms and computing technology, the accuracy of dose calculation seems close to our clinical needs. Next-generation dose calculation algorithms are expected to include biologically equivalent doses or biologically effective doses, and doctors expect to be able to use them to improve the quality of treatment in the near future.

A Study for Dose-Reduction of Antipsychotics in Chronic Schizophrenics (만성 정신분열병 환자에서 항정신병약물 감량에 관한 연구)

  • Hwang, Tae-Yeon;Lee, Min Soo;Kim, Hyeong-Seob
    • Korean Journal of Biological Psychiatry
    • /
    • v.5 no.2
    • /
    • pp.263-277
    • /
    • 1998
  • Conventional high-dose antipsychotics tend to result in more side effects, negative symptoms and dysphoria, and at the same time lower the cognitive function which is already impaired in most schizophrenics. Florid psychotic symptoms, negative symptoms and cognitive impairment greatly impede psychosocial performance and eventual reintegration into society. The reduction of symptom and the improvement of cognitive funtions and social skills are therefore central to the psychiatric rehabilitation process. The purpose of this study was to evaluate the dose-reduction effects of antipsychotics on chronic schizophrenics prescribed conventional high-dose antipsychotics more than 1,500mg equivalent of chlorpromazine. Fifty-one chronic schizophrenics who maintained high-dose antipsychotics for more than three months were randomly assigned to two groups : 20 patients comprised the dose-maintaining group and 31 patients made the dose-reduction group. Over a sixteen weekperiod Positive and Negative Syndrome Scale(PANSS), Extrapyramidal Symptom(EPS), Nurses' Observation Scale for Inpatient Evaluation(NOSIE-30), Continuous Performance Test(CPT), Quality of Life(QOL), and haloperidol/reduced haloperidol blood levels were determined at the base line and after 2, 4, 6, 8, 12, 16 weeks to evaluate the dose reduction effects of high-dose antipsychotics. The results were as follows : 1) Dose-reduction is highly effective in reducing positive and negative symptoms, and general psychopathology. Effects were most prominent at 8, 12, 16 weeks. Among the dose reduction group, positive symptoms in positive symptom group and negative symptoms in negative symptom group were more reduced. 2 Extrapyramidal symptoms showed no significant difference between two groups. But the EPS was reduced time after time within two groups. 3) Hit rates of Continuous Performance Test, which indicate attentional capacity, increased significantly after dose reduction. 4) Haloperidol and reduced haloperidol blood levels decreased until the 4th week, after which they were constant. 5) Total scores of Nurses' Observation Scale for Inpatient Evaluation were unchanged between the two groups. But among the indices, social interest and personal neatness were improved in the dose-reduction group and retardation was aggrevated in the dose-maintaining group. 6) Total quality of life scores were unchanged between two groups. But in the dose maintaining group, satisfaction scores of attention, autonomy, and interpersonal relationship decreased progressively. These findings suggest that the dose reduction of antipsychotics for chronic schizophrenics on programs of high-dose antipsychotics were effective. Dose reduction should therefore be implemanted to spread the rehabilitation and improve quality of life for chronic schizophrenics.

  • PDF