• Title/Summary/Keyword: effect of fire

Search Result 1,357, Processing Time 0.038 seconds

The Effect of Epoxy Resin on the Properties of Encapsulated Fire Extinguishing Agent (캡슐화된 소화약제의 물성에 대한 고분자 매트릭스의 효과)

  • Alexandra, Sertsova;Sergei, Krasilnikov;Lee, Sang-Sup;Kim, Jong-Sang.
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.19-27
    • /
    • 2019
  • Fire extinguishing composite materials based on low-viscosity epoxy resin (EP) and containing 50 wt% of encapsulated fire extinguishing agent (EFA) have been studied. The positive effect of the EP on the kinetics and temperature of the EFA decapsulation was established. The EP increases the decapsulation temperature of the EFA from 130 ℃ to 155 ℃ and changes the kinetics of the decapsulation. The epoxy matrix increases the thermal stability of the EFA more than 3.9 times compared to that of the pure EFA. The protective effect of the EP on the storage stability of the EFA was validated. The mass loss of EP-containing EFA at 60 ℃ and 80% humidity over 96 h is 0.4%. The mass loss of pure EFA under the same conditions is 15%. A similar effect was observed under ultraviolet radiation: the EP-containing EFA loses 0.8% at pure EFA mass of 6%. The testing of alternative polymer matrixes has been considered.

Effect of Platform Screen Door on fire in the subway station (스크린도어가 설치된 지하철 승강장의 화재유동 전산 수치 모사를 이용한 스크린도어의 화재 영향 연구)

  • Jang, Yong-Jun;Jung, Woo-Sung;Park, Won-Hee;Kim, Hag-Beom
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1337-1345
    • /
    • 2007
  • The present study is a basic investigation for systematically proceeding disaster prevention studying the effect of platform screen door in case of fire at the subway station. In the paper, the characteristics of screen door were surveyed and described. The fully closed platform screen door and the island type of subway station were employed for simulation-study. Numerical simulations of fire driven flow at the subway station with platform screen door were performed with commercial fire CFD code. For analyzing of the effect of platform screen door, the fire simulations with and without the platform screen door were compared. For the fire location, the one is located on the platform and the other case on the railway. The Ultrafast model was taken as fire growth scenario. The maximum heat release rate was 10MW. The propagated time of the heat and smoke to stairs was within 4 minute when the fire is located on the platform. However the heat and smoke propagation was block off by screen door when the fire is located on the railway.

  • PDF

A Numerical Study of Smoke Movement with Radiation in Atrium Fires (아트리움에서 화재 발생시 복사가 고려된 연기거동에 대한 수치해석 연구)

  • 정진용;유홍선;홍기배
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.7-15
    • /
    • 2001
  • This paper describes the smoke filling process of a fire field model based on a self-developed SMEP (Smoke Movement Estimating Program) codo to the simulation of fire induced flows in the atrium space (SIVANS atrium at Japan) containing smoke radiation effect. The SMEP using PISO algorithm solves conservation equations for mass, momentum, energy and species, together with those for the modified k-$\varepsilon$ turbulence model with buoyancy term. Also it solves the radiation equation using the discrete ordinates method. The result of the calculated smoke temperature containing radiation effect has shown a better prediction than the result calculated by only convection effect in comparison with the experimental data. This seems to come from the radiation effect of $H_2$O and $CO_2$ gas under smoke productions. Thus, the consideration of the radiation effect under smoke in fire should be necessary in order to get more realistic result. Also the numerical results indicated that the smoke layer is developing at a rate of about 0.1 m/s. It would take about 450 seconds after starting the ultra fast fire of 560 kW that the smoke layer move down to 1.5m above the escape level.

  • PDF

Structural Fire Analysis of a Composite Beam Protected by Fire-Resistant Materials (내화피복을 적용한 강합성보의 구조화재해석)

  • Jun Won Kang;Moon Soo Kang;Hyejin Yoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.2
    • /
    • pp.137-145
    • /
    • 2023
  • This paper presents the effects of fire-resistant materials on the temperature and vertical deflection of a composite beam exposed to fire through nonlinear thermo-mechanical analysis. The fire was modeled using the standard fire curve proposed in American Society for Testing and Materials (ASTM) E119. Fire-resistant materials were modeled by reducing the heat transfer coefficient from the air layer to the beam. The temperature and vertical deflection of the uncoated composite beam were measured using a laboratory fire test, and the results of the structural fire analysis were verified through comparison with experimental results. By introducing the fire-resistance effect, the reduction in the temperature and deflection of the beam for the ASTM E119 standard fire can be reasonably estimated. Based on a case study of the heat transfer coefficient, the fire-resistant effect on the thermo-mechanical response of a composite beam in the event of a fire is presented.

Reliability Assessment of Forest Fire on Transmission Lines Polymer Insulator(I) (송전용 폴리머 애자의 산불영향 신뢰성 평가(I))

  • Choi, In-Hyuk;Lee, Il-Dong;Jeon, Young-Joon;Lee, Chul-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.425-428
    • /
    • 2004
  • 65% of the Korean peninsula is composed of mountainous area, 97% of which is composed of forest. Therefore, there is high possibility of mountain fire because a lot of potential inflammables such as fallen leaves are stacked on the ground. Moreover, most of the overhead transmission lines in Korea are operated on the mountain. However, there has been very little study for the effect of mountain fire on polymeric insulator for transmission line, though the study is significantly required Therefore, in this study the authors observed the deformation of the housing of the insulator under fire with respect to the ignition time, using artificial ignition testing equipment, and investigated electrical and mechanical characteristics of the insulator by dry withstand voltage test, impulse flashover test and tensile load test.

  • PDF

Study on the Ejected Plume from Opening Regarding Side-wall Effect in Fire (측벽효과를 고려한 개구부 분출화염 거동 연구)

  • Jeong, Jae-Gun;Shin, Yi-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.219-220
    • /
    • 2016
  • The behavior of fire plumes has not yet been clearly identified for cases where sidewalls are installed near an opening in an unconfined space. In this research, we aim to quantitatively identify the effects on fire spread when sidewalls are located on both sides of an opening. Specifically, we focus on the effects on the fire plume of the relation between the location of sidewalls and the opening, and carry out a scale-model experiment to devise a flame height model and to evaluate the temperature distribution along the central axis of the flame.

  • PDF

Relationship between Stress and Job Satisfaction of Fire-fighters (소방공무원의 스트레스 요인과 직무만족간의 관계)

  • Ryu, Sang-Il;Cho, Jong-Mook
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.270-278
    • /
    • 2009
  • Most of previous studies on civil servants' stress factors and job satisfaction have been focused on low job satisfaction caused by stress from role relations and human relations. In case of fire officers, however, their stress is expected to be influenced by their unique job characteristics such as risk, urgency, stand-by, and shift. Thus, this study divided fire officers'stress factors into job-related factors (risk, urgency, stand-by, alternation) and role-related factors (role conflict, role ambiguity, role overload), and empirically analyzed how these factors affect their job satisfaction. According to the results of this study, fire officers' job characteristics and their roles in the organization had a significant effect on their job satisfaction. Particularly, among the job-related factors, urgency and stand-by had a positive effect on job satisfaction, and among role-related factors, role conflict and role overload had a negative effect on job satisfaction. In addition, fire officers' stress and job satisfaction were significantly different according to their job (fire fighting, rescue and first aid, fire administration, others), and according to their workplace (fire fighting headquarters, fire station, 119 safety center).