• 제목/요약/키워드: effect of fire

검색결과 1,357건 처리시간 0.029초

아파트에 설치하는 옥내소화전 압력계 설치가 배관의 가압수 식별 및 자체점검 용이성 간의 영향 분석 (An Analysis on the Effect of Pressure System Installation on the Pipeline to Identify Pressurized Water and Self-inspection Ease in Apartment Building)

  • 손주달;공하성
    • 대한안전경영과학회지
    • /
    • 제22권1호
    • /
    • pp.33-44
    • /
    • 2020
  • This study analyzed how the installation of a pressure gauge in the indoor fire hydrant of an apartment building affected identifying pressurized water in the pipe, making it easier to conduct internal inspection on the fire suppression system, and ensuring reliability of fire suppression. The following are the study's results: First, identifying pressurized water in the indoor firefighting pipe had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that a higher level of identification of pressurized water in the indoor firefighting pipe had a positive impact on improving the installation and use of a pressure gauge in the indoor fire hydrant. Second, making it easier for the fire safety officer to inspect the fire suppression system had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This suggests that if it becomes easier for the apartment building's stakeholder to conduct internal inspection or the firefighting facility manager to carry out inspection on the fire suppression system, it would have a positive effect on the installation of a pressure gauge in the indoor fire hydrant. Finally, ensuring reliability in fire suppression had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that if it becomes easier to identify pressurized water in the indoor firefighting pipe, for the fire safety officer to conduct internal inspection, or for the firefighting facility manager to carry out inspection in accordance with the fire suppression system's internal inspection requirements, it would increase reliability in fire suppression, making it more necessary to install a pressure gauge in the indoor fire hydrant.

정압기지에 대한 산불화재 영향평가 (Effect Evaluation of Forest Fire on Governor Station)

  • 장서일;차순철;강경식
    • 대한안전경영과학회지
    • /
    • 제9권2호
    • /
    • pp.49-57
    • /
    • 2007
  • This Study is to suggest a method of effect evaluation of forest fire on governor station in shrub land. Theoretically, to evaluate effects of forest fire, it is combined that Spread Rate of Forest Fire, Flame Model, and Thermal Radiation Effects Model; i.e. a travel time of forest fire is calculated by Spread Rate of Forest Fire, fire-line intensity is calculated by Flame Model, and effects of fire-line intensity is affected by Thermal Radiation Effects Model. With the aforementioned method, we could carry out the effect evaluation of forest fire on governor station in shrub land and could distinguish scenarios to need protection plan from all scenarios.

화재예방에 영향을 미치는 요인에 관한 연구 (A Study on Factors Affecting Fire Prevention)

  • 채진
    • 한국화재소방학회논문지
    • /
    • 제34권3호
    • /
    • pp.100-109
    • /
    • 2020
  • 본 연구는 화재예방과 관련된 안전문화 조성, 화재예방 교육, 화재예방 설비, 화재안전 지식, 화재안전 실천을 독립변수로 두고, 종속변수인 화재예방에 미치는 영향요인을 실증적으로 검증하기 위한 연구이다. 다중회귀분석에서 얻어진 결과는 화재예방과 관련하여 다음과 같이 도출되었다. 화재예방 교육은 화재예방에 통계적으로 가장 강하게 유의미한 영향을 미치는 것으로 나타났으며, 화재예방 설비는 화재예방에 통계적으로 유의미한 영향을 미치는 것으로 나타났다. 또한 화재안전 실천은 화재예방에 통계적으로 유의미한 영향을 미치는 것으로 나타났다.

Numerical analysis of simply supported two-way reinforced concrete slabs under fire

  • Wenjun Wang;Binhui Jiang;Fa-xing Ding;Zhiwu Yu
    • Computers and Concrete
    • /
    • 제31권6호
    • /
    • pp.469-484
    • /
    • 2023
  • The response mechanism of simply supported two-way reinforced concrete (RC) slabs under fire was numerically studied from the view of stress redistribution using the finite element software ABAQUS. Results show that: (1) Simply supported two-way RC slabs undergo intense stress redistribution, and their responses show four stages, namely elastic, elastic-plastic, plastic and tensile membrane stages. There is no cracking in the fire area of the slabs until the tensile membrane stage. (2) The inverted arch effect and tensile membrane effect improve the fire resistance of the two-way slabs. When the deflection is L/20, the slab is in an inverted arch effect state, and the slab still has a good deflection reserve. The deformation rate of the slab in the tensile membrane stage is smaller than that in the elastic-plastic and plastic stages. (3) Fire resistance of square slabs is better than that of rectangular slabs. Besides, increasing the reinforcement ratio or slab thickness improves the fire resistance of the slabs. However, an increase of cover thickness has little effect on the fire resistance of two-way slabs. (4) Compared with one-way slabs, the time for two-way slabs to enter the plastic and tensile cracking stage is postponed, and the deformation rate in the plastic and tensile cracking stage is also slowed down. (5) The simply supported two-way RC slabs can satisfy with the requirements of a class I fire resistance rating of 90 min without additional fire protection.

Effect of Fire Induced Spalling on the Response of Reinforced Concrete Beams

  • Kodur, V.K.R.;Dwaikat, M.B.
    • International Journal of Concrete Structures and Materials
    • /
    • 제2권2호
    • /
    • pp.71-81
    • /
    • 2008
  • A macroscopic finite element model is applied to investigate the effect of fire induced spalling on the response of reinforced concrete (RC) beams. Spalling is accounted for in the model through pore pressure calculations in concrete. The principles of mechanics and thermodynamics are applied to compute the temperature induced pore pressure in the concrete structures as a function of fire exposure time. The computed pore pressure is checked against the temperature dependent tensile strength of concrete to determine the extent of spalling. Using the model, case studies are conducted to investigate the influence of concrete permeability, fire scenario and axial restraint on the fire induced spalling and also on the response of RC beams. Results from the analysis indicate that the fire induced spalling, fire scenario, and axial restraint have significant influence on the fire response of RC beams. It is also shown that concrete permeability has substantial effect on the fire induced spalling and thus on the fire response of concrete beams. The fire resistance of high strength concrete beams can be lower that that of normal strength concrete beams due to fire induced spalling resulting from low permeability in high strength concrete.

화재 성장 모델이 객차내 화재 특성에 미치는 영향에 관한 수치해석적 연구 (A Numerical Study of the Effect off Fire Growth Model on Fire Characteristics in a Carriage)

  • 김성찬;유홍선;최영기;김동현
    • 한국철도학회논문집
    • /
    • 제7권3호
    • /
    • pp.180-185
    • /
    • 2004
  • The present study investigates the effect of fire growth model on fire development characteristics in a carriage. The parallel processing version of FDS code is used to simulate the fire driven flow in a carriage and two types of fire growth model which are flame spread model and t$^2$ model are examined for the same geometrical condition. The heat release rates(HRR) of both model are similar each other until 30 s after ignition, but the flame spread model predicts 5 times higher than those of the t$^2$ fire model during the quasi-steady fire period. Maximum heat release rate in the case of flame spread model reaches about to 12 MW at 100 s after fire ignition. Also, various database of fire properties for combustible materials and more elaborate combustion model considering the flame spreading phenomena are required for better predictions of fire development characteristics using numerical simulation.

소방공무원들이 인지하는 소방장비 보급으로 소방장비 만족도에 미치는 영향: 소방장비 신뢰성의 매개효과를 중심으로 (Influence on the Satisfaction of Fire Fighting Equipment by Distribution of Fire Fighting Equipment: Focusing on Mediating Effect of Reliability of Fire Fighting Equipment)

  • 이선범;김양현
    • 한국콘텐츠학회논문지
    • /
    • 제17권8호
    • /
    • pp.677-684
    • /
    • 2017
  • 본 연구는 소방장비의 발전을 위해 필요한 기초자료를 제공하기 위하여 소방공무원들이 인지한 소방장비 보급이 소방장비 만족도에 미치는 영향, 이 두변수 사이에서 소방장비 신뢰성의 매개효과를 검증하였다. 연구의 목적을 달성하기 위하여 경기도 7개 소방서의 소방공무원을 대상으로 설문을 실시하였다. 이렇게 수집된 자료는 AMOS 18.0을 사용하여 구조방정식모형을 통한 분석을 실시하였다. 주요한 연구결과는 다음과 같다. 첫째, 소방장비 보급량의 적절성과 보급의 적시성은 소방장비 신뢰성에 정(+)의 영향을 미치고 있었다. 둘째, 소방장비 신뢰성은 소방장비 만족도에 정(+)의 영향을 미치고 있었다. 셋째, 소방장비 보급량의 적절성은 소방장비 만족도에 정(+)의 영향을 미치고 있었다. 소방장비 신뢰성은 소방장비 보급량의 적절성과 소방장비 만족도와의 관계에 있어서 부분매개효과가 있다는 것을 알 수 있었다.

시뮬레이션을 이용한 화재 시 고층건축물의 압력분포 특성에 관한 연구 (A Sutdy on the Pressure Distribution Characteristic of High-rise Buildings in Fire Using Computer Simulation)

  • 김혜원;이병흔;진승현;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.49-50
    • /
    • 2019
  • In the case of High-rise buildings, it has a problem by stack effect that rise of vertical height. Especially in case of fire, it need to the consideration of stack effect that it has bigger than general. Therefore in this study, we used to the Contamw and FDS simulation for analysis of stack effect and pressure distribution characteristic in fire. As a result the Contamw simulation shows the pressure distribution by stack effect in general high-rise buildings. However, in case of fire, the height of the neutral plane is lowered and stack effect is larger. Therefore, it is necessary to multiply analyze the temperature distribution and the stack effect in fire.

  • PDF

A Numerical Investigation on Restrained High Strength Q460 Steel Beams Including Creep Effect

  • Wang, Weiyong;Zhang, Linbo;He, Pingzhao
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1497-1507
    • /
    • 2018
  • Most of previous studies on fire resistance of restrained steel beams neglected creep effect due to lack of suitable creep model. This paper presents a finite element model (FEM) for accessing the fire resistance of restrained high strength Q460 steel beams by taking high temperature Norton creep model of steel into consideration. The validation of the established model is verified by comparing the axial force and deflection of restrained beams obtained by finite element analysis with test results. In order to explore the creep effect on fire response of restrained Q460 steel beams, the thermal axial force and deflection of the beams are also analyzed excluding creep effect. Results from comparison infer that creep plays a crucial role in fire response of restrained steel beam and neglecting the effect of creep may lead to unsafe design. A set of parametric studies are accomplished by using the calibrated FEM to evaluate the governed factors influencing fire response of restrained Q460 steel beams. The parametric studies indicate that load level, rotational restraint stiffness, span-depth ratio, heating rate and temperature distribution pattern are key factors in determining fire resistance of restrained Q460 steel beam. A simplified design approach to determine the moment capacity of restrained Q460 steel beams is proposed based on the parametric studies by considering creep effect.

Performance of fire damaged steel reinforced high strength concrete (SRHSC) columns

  • Choi, Eun Gyu;Kim, Hee Sun;Shin, Yeong Soo
    • Steel and Composite Structures
    • /
    • 제13권6호
    • /
    • pp.521-537
    • /
    • 2012
  • In this study, an experimental study is performed to understand the effect of spalling on the structural behavior of fire damaged steel reinforced high strength concrete (SRHSC) columns, and the test results of temperature distributions and the displacements at elevated temperature are analyzed. Toward this goal, three long columns are tested to investigate the effect of various test parameters on structural behavior during the fire, and twelve short columns are tested to investigate residual strength and stiffness after the fire. The test parameters are mixture ratios of polypropylene fiber (0 and 0.1 vol.%), magnitudes of applied loads (concentric loads and eccentric loads), and the time period of exposure to fire (0, 30, 60 and 90 minutes). The experimental results show that there is significant effect of loading on the structural behaviors of columns under fire. The loaded concrete columns result more explosive spalling than the unloaded columns under fire. In particular, eccentrically loaded columns are severely spalled. The temperature distributions of the concrete are not affected by the loading state if there is no spalling. However, the loading state affects the temperature distributions when there is spalling occurred. In addition, it is found that polypropylene fiber prevents spalling of both loaded and unloaded columns under fire. From these experimental findings, an equation of predicting residual load capacity of the fire damaged column is proposed.