• 제목/요약/키워드: eddy-current

검색결과 1,085건 처리시간 0.035초

자화패턴에 따른 영구자석 직선형 와전류 제동장치의 특성 해석 (Characteristic Analysis of Permanent-Magnet Linear Eddy-Current Brake System According to Magnetization Pattern)

  • 이성호;조한욱;장석명
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권9호
    • /
    • pp.427-433
    • /
    • 2003
  • Permanent magnet movers with three different magnetization patterns were applied to a linear eddy current braking system. By using a two-dimensional analytical technique, this paper deals with the comparison of the design guidelines, magnetic field, required magnet volume, and force capability for three types of linear brakes. The analytical results are also verified by finite element analyses.

경계요소해석을 이용한 와전류 센서의 특성 해석 (Analyse of characteristic of Eddy current sensor using Boundary Element Method)

  • 윤만식;최덕수;양규창;이향범;박승한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.697-699
    • /
    • 2002
  • In this paper, the characteristics analysis of the eddy current sensor by using boundary element method package is presented. For the boundary element analysis. Faraday, which is the commercial package of the integrated engineering software, is used. To observe the impedance characteristic of the eddy current senor with the sensor position and lift-off, the eddy current testing analysis is performed on the ferromagnetic plate with defect. Considering the skin depth of the ferromagnetic specimen, the 800(Hz) driving source is chosen. The result shows that electro motive force is reduced as the probe moves to near the defect and the lift-off of the probe increases.

  • PDF

자기장 센서를 이용한 갭간격이 없는 박판 맞대기 용접부의 용접선 추적 장치 (Joint tracking system for butt joint welding process using eddy current sensors with the condition of no gap distance)

  • 김영선;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.836-839
    • /
    • 1997
  • In recent years, much progress has been made in the automation of welding coped with a variety of highly flexible sensors. Among these sensors, only the eddy current sensor can detect the center location of the butt joint whose gap distance is zero. Thus, in this study the eddy current sensor is used to develop a robust and useful joint tracking system. The developed system is tested to qualify the performance of the system and seam tracking algorithm is proposed and two simulation are executed to show the performance of the proposed tracking algorithm.

  • PDF

Noninvasive measuring;Detections of materials and quantities on eddy current testing

  • Obayashi, Koji;Tamura, Muneyoshi;Zhang, X.;Aoyama, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1555-1560
    • /
    • 2004
  • We made a simplified eddy-current-tester, and observed some materials for the ingredients and mass and locations. The tester detects the current as frequency shifts of a LC-resonance circuit, which are caused by the eddy currents. Using air-wick coil and a multi-piled ceramic capacitor, we made a resonance system whose frequency was 100KHz. The shift quantity is few; so, to detect it, we used a frequency counter, and counted the shift. We can detect 10Hz order's shift.

  • PDF

와전류법을 이용한 강의 표면경화층 깊이의 비파괴적 측정 (Nondestructive Measurement of Case Hardening Depth with Eddy Current Method)

  • 이계완;한승룡;박은수
    • 비파괴검사학회지
    • /
    • 제11권1호
    • /
    • pp.38-43
    • /
    • 1991
  • The relationship between eddy current response and case hardening depth has been studied on SM40C(KS D-3752) and SCM440(KS D-3711) steels which were surface hardened by high frequency induction hardening. The results obtained in this study were as follows ; 1) Case hardening depth was successfully measured by observing the eddy current impedance changes of each steel. The impedance decreased linearly with increasing case hardening depth. 2) For large impedance gradient between the hardened surface and core metal, the eddy current response was more sensitive to case hardening depth than for low impedance gradient.

  • PDF

다자유도 구형 구동 모터의 와전류 손실 저감을 통한 효율 향상 연구 (Improve of efficiency of Multi D.O.F spherical motor through the reduction of eddy current loss)

  • 홍경표;이원국;이호준;강동우;원성홍;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.947-948
    • /
    • 2011
  • Efficiency of Multi D.O.F spherical motor is one of the important performance indicators. So Through the reduction of eddy current loss on how to improve the efficiency were studied. Stator iron core's material with high permeability and resistivity of material using the eddy current loss was reduced. However, it was the disadvantages of production and economic. For these reasons, prevent eddy current loss of the iron core of multi D.O.F spherical motor as a viable alternative to motor using rotor with double-air gap.

  • PDF

전선 부식에 따른 와전류특성 조사 (A Study of Eddy Current Characteristics which Follows in the Corrosion of Power line)

  • 오용철;정한석;이재봉;임주혁;손기정;김진사;김충혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.77-77
    • /
    • 2010
  • We used eddy current sensor for diagnosis of power line. The power line according to the cross section has 6~18 element wires. The corrosion of power line was made by sodium hydroxide. The corrosion time of power line was from 18 hours to 27 hours. We obtained physical characteristics from tensile and torsion tests of power line. The eddy current Characteristics of power line according to the corrosion appeared change of amplitude 200 ~ 800 mV.

  • PDF

Analysis of Mechanical Fixation Made of Aluminum Alloy in an Axial Flux Permanent Magnet Machine

  • Lee, Jiyoung;Park, Byounggung;Koo, Daehyun
    • Journal of Magnetics
    • /
    • 제19권3호
    • /
    • pp.309-313
    • /
    • 2014
  • This paper presents an eddy current loss analysis of a Mechanical Fixation (MF) made of 6061 aluminum alloy, which is used for an NS type double-rotor single-stator axial flux permanent magnet machine. The prototype MF made of aluminum alloy shows good mechanical performance, but poor electro-magnetic performance, since the machine's efficiency can decrease because of eddy current loss in the MF. In order to prevent efficiency decrease, a modification of the MF structure is also introduced. Three-dimensional finite element analysis (FEA) is used for magnetic field analysis, and eddy current losses are computed. The analysis results are compared to, and verified by the test results.

A Simple Analytical Model for the Interaction between the East Korean Warm Current and the Ulleung Warm Eddy

  • Seung, Young-Ho
    • Journal of the korean society of oceanography
    • /
    • 제37권1호
    • /
    • pp.20-26
    • /
    • 2002
  • The offshore extension of the East Korean Warm Current (EKWC) mostly turns anti-cyclonically around the Ulleung Warm Eddy (UWE). This fact needs to be dynamically explained because a rectilinear stream past a circular cylinder is normally expected to have a flow pattern symmetric about the stream axis. For this purpose, a simple analytical model is presented in this paper. This model shows that the EKWC's tendency to be anti-cyclonic around the UWE is due to the anti cyclonic circulation generated around the UWE. This tendency results from the geostrophic adjustment between the UWE and the ambient EKWC water. As the strength of the UWE decreases, relative to the EKWC, this model shows that the flow pattern gradually changes from circular to rectilinear.

레이저 표면경화 공정에서 경화층깊이의 실시간 측정을 위한 실험적 연구 (An experimental study on the in-process measurement of case depth for LASER surface hardening process)

  • Woo, H.G.;Park, Y.J.;Han, Y.H.
    • 한국정밀공학회지
    • /
    • 제10권2호
    • /
    • pp.66-75
    • /
    • 1993
  • This paper proposes a monitoring method for nondestructive and in-process measurement of the case depth in LASER surface heat treatment process. The method is essentially an eddy-current method, and measures sensing coil's electrical impedance which varies with the changes of the material microstructure due to hardening. To investigate te validity of the proposed method a series of experiments were performed for various hardning depths. The results show that the relationship between the eddy- current sensor output and the changes in case depth is almost linear. This indicates that the eddy-current measuring method can be used as one of the possible monitoring method for mesauring the hardened depth in LASER heat treatment processes.