• Title/Summary/Keyword: dynamic tests

Search Result 2,298, Processing Time 0.037 seconds

A Study on the Thermal and Chemical Properties of Carbon Nanotube Reinforced Nanocomposite in Power Cables

  • Yang, Sang-Hyun;Jang, Hyeok-Jin;Park, Noh-Joon;Park, Dae-Hee;Yang, Hoon;Bang, Jeong-Hwan
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.6
    • /
    • pp.217-221
    • /
    • 2009
  • The use of the carbon nanotube (CNT) is superior to the general powder state materials in their thermal and chemical properties. Because its ratio of diameter to length (aspect ratio) is very large, it is known to be a type of ideal nano-reinforcement material. Based on this advantage, the existing carbon black of the semiconductive shield materials used in power cables can acquire excellent properties by the use of a small amount of CNTs. Therefore, we fabricated specimens using a solution mixing method. We investigated the thermal properties of the CNT, such as its storage modulus, loss modulus, and its tan delta using a dynamic mechanical analysis 2980. We found that a high thermal resistance level is demonstrated by using a small amount of CNTs. We also investigated the chemical properties of the CNT, such as the oxidation reaction by using Fourier transform infrared spectroscopy (FT-IR) made by Travel IR. In the case of the FT-IR tests, we searched for some degree of oxidation by detecting the carboxyl group (C=O). The results confirm a tendency for a high cross-linking density in a new network in which the CNTs situated between the carbon black constituent molecules show a bond using similar constructive properties.

Measurement of Liquid Oscillation in Tuned Liquid Dampers using a Laser Doppler Vibrometer (레이저진동계를 사용한 동조액체댐퍼의 액체 진동 측정)

  • Shin, Yoon-Soo;Min, Kyung-Won;Kim, Junhee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.6
    • /
    • pp.513-519
    • /
    • 2016
  • In this study, dynamic vertical displacement of liquid in the tuned liquid column damper(TLCD) is measured by a laser Doppler vibrometer(LDV) to overcome limitations of existing sensors and to leverage noncontact sensing. Addressing advantages of noncontact measurements, operational principles of the LDV to measure velocity and displacement of a target object in motion is explained. The feasibility of application of the LDV to measurement of liquid motion in the TLCD is experimentally explored. A series of shake table tests with the TLCD are performed to determine requirements of application of the LDV. Based on the experimental results, it is proved that the LDV works under the condition of adding dye to the liquid by increasing the intensity of reflected laser and thus validity is verified by comparison with a conventional wave height meter.

Ground-Structure Seismic Interaction-Induced Rocking Behavior and the Uplift Behavior of Underground Hollow Structure (지반-구조물 동적 상호작용에 의한 Rocking현상과 그에 따른 지하 중공구조물의 부상거동)

  • Kang, Gi-Chun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.3C
    • /
    • pp.85-94
    • /
    • 2012
  • This paper described a centrifuge study in order to investigate ground-underground hollow structure interaction-induced rocking behavior in liquefied ground. Uplift of the underground hollow structures is initiated due to liquefaction in sandy grounds when the ground is exposed to a strong shaking during earthquakes because the apparent unit weight of these structures is smaller than that of the liquefied soil. In order to evaluate the dynamic behavior of the underground hollow structure and the effects of original subsoil during the uplifting, model tests were performed by changing the relative density of the original subsoil and installing an acrylic box as a trench. The results of the present study show that rocking behavior of the underground hollow structure due to shear deformation of the surrounding subsoil or lateral movement from the original subsoil contributed to large magnitude of the uplift due to strong shaking.

Study of Cure Kinetics of Vacuum Bag Only Prepreg Using Differential Scanning Calorimetry (시차주사열량계를 이용한 진공백 성형 프리프레그의 경화 거동 연구)

  • Hyun, Dong Keun;Lee, Byoung Eon;Shin, Do Hoon;Kim, Ji Hoon
    • Composites Research
    • /
    • v.33 no.2
    • /
    • pp.44-49
    • /
    • 2020
  • The cure kinetics of carbon fiber-reinforced prepreg for Vacuum Bag Only(VBO) process was studied by differential scanning calorimetry (DSC). The total heat of reaction (ΔHtotal = 537.1 J/g) was defined by the dynamic scanning test using prepregs and isothermal scanning tests were performed at 130℃~180℃. The test results of isothermal scanning were observed that the heat of reaction was increased as the temperature elevated. The Kratz model was applied to analyze the cure kinetics of resin based on the test results. To verify the simulation model, the degree of cure from panels using different cure cycles were compared with the measurement. The simulation model showed that the error against the experimental value was less than 3.4%.

A Study on Wear Properties of Solid lubricating Greaphite Materials (고체윤활 Graphite 소재의 마모 특성에 관한 연구)

  • Yang, Hoyoung;Kim, Jaehoon;Kim, Yeonwook;Ha, Jaeseok;Park, Sunghan;Lee, Hwankyu
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.5
    • /
    • pp.95-100
    • /
    • 2013
  • The important design factors for designing solid lubricating of dynamic seal are tightness, wear resistance and lubricant films. In this study, the effect factors influenced solid lubricating properties of the graphite were analyzed and wear behaviour caused for various test conditions was compared with results obtained from reciprocating wear tests. Also the optimal conditions for formation of lubricant films were investigate to evaluate wear properties of graphite materials. The repeated procedure for the formation of wear particles and lubricant films, and the dissipation of lubricant films was estimated the wear mechanisms with changes of wear depth. Therefore the lubricant film of graphite seal was generated by adhesion of wear particles on the worn surface and it was very useful in wear characteristics.

Development of FBG Accelerometer for Railway Tunnel Vibration (철도터널 진동 모니터링을 위한 광섬유 가속도계 개발)

  • Lee, Su-Hyung;Shin, Min-Ho;Kim, Hyun-Ki;Lee, Kyu-Wan
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.4
    • /
    • pp.364-369
    • /
    • 2011
  • For the safety management of tunnel, effective measurements should be continuously carried out. Most of sensors currently being applied for tunnels measure only the local status, thus many of them are needed to monitor an entire tunnel. For the railway tunnel where trains of same conditions are regularly operated, dynamic responses of tunnel structure to train operations can be a good index to estimate the deformation of tunnel structure in wide area. Meanwhile, the electromagnetic interference caused by overhead centenary in railway tunnel obstructs the use of electric-based sensors. In this study a brand new accelerometer using FBG optical fiber sensors is developed to solve these problems. Sensitivity and capacity of the accelerometer are enhanced with effective structural design of its components and verified with laboratory tests. A case history where the developed accelerometers were applied to a safety monitoring system of a high-speed train tunnel is presented. The performances of the developed accelerometers are validated from the measured acceleration data.

Effects of Therapeutic Climbing Training on the Balance and Gait Ability in Chronic Stroke Patients

  • Lee, Soin;Ko, Mingyun;Park, Seju
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.3
    • /
    • pp.2126-2134
    • /
    • 2020
  • Background: Therapeutic climbing training, which originated in Germany, is a wall-hanging rock climbing-based therapy to increase the body's coordination through movement of the upper and lower limbs against gravity. However, there are no studies examining the effectiveness of therapeutic climbing training to treat balance and gait ability in patients with chronic stroke. Objectives: To investigate therapeutic climbing training program on balance and gait in patients with chronic stroke. Design: Pretest-posttest control group design. Methods: Fourteen patients with chronic hemiplegic stroke participated. Participants were randomized into the therapeutic climbing training group (TCTG, n=7) and the standard rehabilitation program group (SRPG, n=7) group. All subjects participated in the same standard rehabilitation program consisting of 60 minutes 5 times a week for 6 weeks. TCTG participated additionally in the therapeutic climbing program consisting of 30 minutes sessions 3 times a week for the same 6 weeks. Berg balance scale (BBS), Gaitview Measure, Timed up and go test (TUG) were measured. Results: In the TCTG, revealed a statistical difference in BBS between the groups; in the difference of plantar pressure ratio in the static standing position revealed a statistical difference between the groups after training; the balance ability in the one-leg standing tests increased significantly; the time in TUG decreased significantly after training in both groups; The changes in the difference of dynamic plantar pressure ratio were reduced significantly in the TCTG. Conclusion: Therapeutic climbing training contribute to improve balance and walking function in patients with chronic stroke.

Korean Nurses과 Nursing Role Conceptions and Professional Commitment (간호사의 역할개념 양상과 간호직에 대한 헌신몰입에 관한 연구)

  • 이상미
    • Journal of Korean Academy of Nursing
    • /
    • v.21 no.3
    • /
    • pp.307-322
    • /
    • 1991
  • The purpose of this exploratory study was to analyze nursing role conceptions and test the relationships between nursing role conceptions and professional commitment among selected Korean nurses. Data were obtained from a convenience sample of 262 practising nurses of varying positions, education, and experience. The total sample represents a response rate of 93 percent. Subscales of Nursing Role Conceptions (Pieta, 1976) were used to measure professional, service, and bureaucratic role conceptions 1 the tool to measure professional commitment was developed by the investigator. The results of this study were as follows. 1. Professional role conception and service role conception were positively related(normative r= .61 : categorical r= .64). Bureaucratic role conception scores(32.6$\pm$4.97) were higher than professional and service role conception scores. 2. Experience was positively related to bureaucratic professional categorical role conception(r= .17, p< .01), and negatively related to bureaucratic professional role discrepancy(r=- .12, p< .01). There was no relationship between experience and service role conception. This study also showed that nurses who had longer experience tended to have higher role conceptions on all three subscales. 3. Nurses with a master's degree had significantly higher professional and bureaucratic role conceptions scores. Bacealaureates graduates had the lowest bureaucratic categorical role conception scores ; associate nurses had the lowest professional categorical role conception scores. 4. Nursing supervisors and head nurses had significantly higher bureaucratic categorical role coneption scores, whereas they had lower bureaucratic normative and professional role conception scores. 5. Age and experience were positively related to professional commitment (r= .24, r= .28). Hierarchical multiple regression analyses showed that the combination of nursing role conceptions explained greater variance in professional commitment pair of the variables alone. Further research employing dynamic designs is needed to execute rigorous tests of causal models of nursing role conceptions and professional commitment. The findings of this study suggest that antecedents and moderating variables of nursing role conception and professional commitment need to be explored for further theoretical. specification and empirical evaluation.

  • PDF

Study on the Response Modification Factor for a Lightweight Steel Panel-Modular Structure Designed as a Dual Frame System (이중골조시스템으로 설계된 복강판-모듈러 구조물의 반응수정계수에 관한 연구)

  • Lee, Eo-Jin;Hong, Sung-Gul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.39-48
    • /
    • 2011
  • In this present study, a response modification factor for a lightweight steel panel-modular system which is not clarified in a current building code was proposed. As a component of the response modification factor, an over-strength factor and a ductility factor were drawn from the nonlinear static analysis curves of the systems modeled on the basis of the performance tests. The final response modification factor was then computed by modifying the previous response modification factor with a MDOF (Multi-Degree-Of-Freedom) base shear modification factor considering the MDOF dynamic behaviors. As a result of computation for the structures designed as a dual frame system, ranging from 2-story to 5-story, the value of 4 was estimated as a final response modification factor for a seismic design, considering the value of 5 as an upper limit of the number of stories.

Seismic Response Estimation of Water Extinguishing Facilities using Shaking Table Tests (진동대 실험을 통한 수계 소화설비의 지진응답평가에 관한 연구)

  • Nam, Min-Jun;Park, Seung-Hee;Kim, Dong-Joon;Choi, Jun-Sung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.9-18
    • /
    • 2012
  • In this study, a shaking table test was performed for the evaluation of water extinguishing facilities. Water extinguishing facilities, such as a general pipe, a seismic pipe (Loof type) and a pump, were used in the experiment. This captured the dynamic characteristics of water extinguishing systems by earthquake records at El-Centro with a 50%, 70%, 100%, 120% level. As a result, seismic type facilities have excellent seismic performance compared to general facilities. By using the acceleration response spectrum, not only is the performance evaluation of water extinguishing facilities able to be determined, but also the deformation of facilities in low earthquake levels can be known. This proposed approach can determine the seismic performance evaluation of water extinguishing facilities and verify seismic performance criteria.