• Title/Summary/Keyword: dynamic range conversion

Search Result 76, Processing Time 0.024 seconds

Comparison and Correlation between Distance Static Stereoacuity and Dynamic Stereoacuity (원거리 정적 입체시와 동적 입체시의 평가 및 상관관계)

  • Kim, Young-Cheong;Kim, Sang-Hyun;Shim, Hyun-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.385-390
    • /
    • 2015
  • Purpose: This study evaluated the static stereoacuity by Distance Randot Stereotest (STEREO OPTICAL. Co., Inc. USA) and the dynamic stereoacuity by three-rods test (iNT, Korea). Criterion and correlation of stereoacuity between both tests and usefulness of two stereotest methods were also evaluated. Methods: For normal adults of 109 (male 61, female 48), mean age of 20.88 (19-32 years) years old, static stereoacuity by using Distance Randot Stereotest at 3 m distance, dynamic stereoacuity by using three-rods test at 2.5 m distance were measured. Results: The mean of distance static stereoacuity was $155.77{\pm}133.11sec$ of arc and the mean of error distance dynamic stereoacuity $11.13{\pm}9.69mm$. With equivalent-conversion stereoacuity of $23.44{\pm}20.96sec$ of arc, there was statistically significant differences (p=0.00) between two dynamic stereoacuity, but correlation was relatively low (${\rho}=0.226$). In the case of dynamic stereoacuity, separated to normal range by criterion of the error distance 20 mm, it showed the error distance of less than 20 mm in 97 subjects(89%) whose average of error distance and conversion mean dynamic stereoacuity were $8.43{\pm}5.10mm$ and $17.68{\pm}10.67sec$ of arc. repectively. The error distance of was equivalent-conversion dynamic stereoacuity 40.99 sec of arc (PD 62 mm basis) was 20 mm. Conclusions: The results of lower correlation between static and dynamic stereoacuity suggest that seterotest should be applied separately to different functions. The results of this study also suggest that Distance Randot Stereotest can be applied to static stereoacuity excluding monocular cues. Three-rods test can be applied to dynamic stereoacuity containing the response of the eye-hand coordination in the daily life of natural vision condition, including the monocular cues. These different approaches canprovide a criterion of the two stereoacuity and parallel use of the two tests would be useful. For dynamic stereoacuity by three-rods test, error distance 20 mm in a normal range of adults can be used as a criteria to get statistical meaning of the results.

Design and Fabrication of a Broadband RF Module for 2.4GHz Band Applications (2.4GHz 대역에서의 응용을 위한 광대역 RF모듈 설계 및 제작)

  • Yang Doo-Yeong;Kang Bong-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.4
    • /
    • pp.1-10
    • /
    • 2006
  • In this paper, a broadband RF module is designed and tested for 2.4GHz band applications. The RF module is composed of a low noise amplifier (LNA) with a three stage amplifier, a single ended gate mixer, matching circuits, a hairpin line band pass filter and a Chebyshev low pass filter to convert the radio frequency (RF) into the intermediate frequency (IF). The LNA has a high gain and stability, and the single ended gate mixer has a high conversion gain and wide dynamic range. In the analysis of the broadband RF module, the composite harmonic balance technique is used to analyze the operating characteristics of an RF module circuit. The RF module has a 55.2dB conversion gain with a 1.54dB low noise figure, $-120{\sim}-60dBm$ wide RF power dynamic range, -60dBm low harmonic spectrum and a good isolation factor among the RF, IF, and local oscillator (LO) ports.

  • PDF

Variable Conversion Gain Mixer for Dual Mode Receiver (이중 모우드 수신기용 가변 변환이득 믹서)

  • Park, Hyun-Woo;Koo, Kyung-Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.2
    • /
    • pp.138-144
    • /
    • 2006
  • In this paper, dual mode FET mixer for WiBro and wireless LAN(WLAN) applications has been designed in the form of dual gate FET mixer by using the cascode structure of two single gate pHEMTs. The designed dual gate mixer has been optimized to have variable conversion gain for WiBro and WLAN applications in order to save dc power consumption. The LO to RF isolation of the designed mixer is more than 20dB from 2.3GHz to 2.5GHz band. With the LO power of 0dBm and RF power of -50dBm, the mixer shows 15dB conversion gain. When RF power increases from -50dBm to -20dBm, the conversion gain decreases to -2dB from 15dB with bias change. The variable conversion gain has several advantages. It can reduce the high dynamic range requirement of AGC burden at IF stage. Also, it can save the dc power dissipation of mixer up to 90%.

  • PDF

Curing Kinetics of the No-Flow Underfill Encapsulant

  • Jung, Hye-Wook;Han, Sang-Gyun;Kim, Min-Young;Kim, Won-Ho
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2001.11a
    • /
    • pp.134-137
    • /
    • 2001
  • The cure kinetics of a cycloalipatic epoxy / anhydride / Co(II) system for a no-flow underfill encapsulant, has been studied by using a differential scanning calorimetry(DSC) under isothermal and dynamic conditions over the temperature range of $160^{\circ}C ~220^{\circ}C$. The kinetic analysis was carried out by fitting dynamic/isothermal heating experimental data to the kinetic expressions to determine the reaction parameters, such as order of reaction and reaction constants. Diffusion-controlled reaction has been observed as the cure conversion increases and successfully analyzed by incorporating the diffusion control term into the rate equation. The prediction of reaction rates by the model equation corresponded well to experimental data at all temperature.

  • PDF

The Development of AC Motor Control System Using DIP-IPM (DIP-IPM을 이용한 전동기 제어시스템 개발)

  • Kim, Nam-Hun;Baik, Won-Sik;Kim, Min-Huei;Kim, Dong-Hee;Choi, Ho-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.232-234
    • /
    • 2002
  • Due to development of power electronics technology, power conversion system are tend to small size, easy to use and light weight. Especially motor control system have increased concerns and interests about IPM(Intelligent Power Module) inverter, which contains protection circuit, drive circuit and power devices. So, we manufactured 3-phase inverter using DIP-IPM(Dual in-line package IPM) PS21245- E(1.5 Kw) made by MITSUBISHI Electric. Some of these features include -HVIC to Provide level shifting and gate drive for high-side IGBTs. The interface circuit between pwm controller and DIP-IPM can made by direct connection. In order to validate dynamic performance of the proposed system, the actual experiment worked out at wide speed range. The developed system is shown as a good dynamic characteristics.

  • PDF

High Dynamic Range Compression using 3D Mesh Processing (삼차원 메쉬 처리를 이용한 고명암 대비 압축)

  • Im, Jong-Guk;Lee, Yun-Jin;Lee, Seung-Yong
    • Journal of the Korea Computer Graphics Society
    • /
    • v.8 no.3
    • /
    • pp.9-16
    • /
    • 2002
  • Recently, high dynamic range (HDR) compression has attracted much attention due to the wide availability of HDR images. In this paper, we present an HDR compression method using a progressive image, which is a multi-level image representation based on a progressive mesh. An HDR image can be decomposed into a base image and a sequence of details by conversion into a progressive image. This decomposition provides a good structure to highly compress the dynamic range while preserving image details. The base image and larger details are considerably scaled down but smaller details are slightly scaled down. Experimental results show that our method successfully generates HDR compressed images without halo artifacts by controlling two intuitive parameters.

  • PDF

Emulator Circuit for a Flux Locked Loop for Detection of Magnetocardiography Signal (심자도 신호 검출을 위한 Flux Locked Loop (FLL) Emulation 회로)

  • 안창범;이동훈;김인기;장경섭;김기태;정동현;최중필
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2749-2752
    • /
    • 2003
  • Magnetocardiography is a very weak biomagnetic field generated from the heart. Since the magnitude of the biomagnetic field is in the order of a few pico Tesla, it is measured with a superconducting quantum interference device (SQUID). SQUID is a transducer converting magnetic flux to voltage, however, its range of linear conversion is very restricted. In order to overcome the narrow dynamic range. a flux locked loop is used to feedback the output field with opposite polarity to the input field so that the total Held becomes zero. This prevents the operating point of the SQUID from moving too far away from the null point thereby escape from the linear region. In this paper, an emulator for the SQUID sensor and feedback coil is proposed. Magnetic courting between the original field and the generated field by the feedback coil is emulated by electronic circuits. By using the emulator, FLL circuits are analyzed and optimized without SQUID sensors. The emulator may be used as a test signal for multi-channel gain calibration and system maintenance.

  • PDF

A Design of High Resolution Temperature Measurement System Using Digital Signal Processor (디지털 신호처리기를 이용한 고분해능 온도측정 시스템 설계)

  • Kim, Tae-Hoon;Lim, Ju-Hyun;Kim, Duck-Young;Ko, Han-Woo;Kim, Sung-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.7
    • /
    • pp.317-322
    • /
    • 2002
  • This paper presents a linear temperature/voltage relation over a temperature range(0~100$^{\circ}C$) with high-resolution, reasonably god response linearity, reliability, and overall improved performance. A notable feature of the proposed method is that the whole temperature span is divided by 16 subbands thus the variation span of measured voltage is narrowed. Therefore noise characteristic has been improved. The output voltage is amplified after the uniformed DC voltage component is eliminated by offset. We proposed circuit using median value and mean value of digital signal in order to reduce the noise effect. The proposed circuit offers linear temperature/voltage conversion over a wide dynamic range using DSP(TMS320C31) and steinhart equation.

Physical principles of digital radiographic imaging system (디지털 방사선영상 시스템의 기본적 원리)

  • Choi, Jin-Woo;Yi, Won-Jin
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.155-158
    • /
    • 2010
  • Digital radiographic systems allow the implementation of a fully digital picture archiving and communication system (PACS), and provide the greater dynamic range of digital detectors with possible reduction of X-ray exposure to the patient. This article reviewed the basic physical principles of digital radiographic imaging system in dental clinics generally. Digital radiography can be divided into computed radiography (CR) and direct radiography (DR). CR systems acquire digital images using phosphor storage plates (PSP) with a separate image readout process. On the other hand, DR systems convert X-rays into electrical charges by means of a direct readout process. DR systems can be further divided into direct and indirect conversion systems depending on the type of X-ray conversion. While a direct conversion requires a photoconductor that converts X-ray photons into electrical charges directly, in an indirect conversion, lightsensitive sensors such as CCD or a flat-panel detector convert visible light, proportional to the incident X-ray energy by a scintillator, into electrical charges. Indirect conversion sensors using CCD or CMOS without lens-coupling are used in intraoral radiography. CR system using PSP is mainly used in extraoral radiographic system and a linear array CCD or CR sensors, in panoramic system. Currently, the digital radiographic system is an important subject in the dental field. Most studies reported that no significant difference in diagnostic performance was found between the digital and conventional systems. To accept advances in technology and utilize benefits provided by the systems, the continuous feedback between doctors and manufacturers is essential.

A CMOS Image Sensor with Analog Gamma Correction using a Nonlinear Single Slope ADC (비선형 단일 기울기 ADC를 사용하여 아날로그 감마 보정을 적용한 CMOS 이미지 센서)

  • Ham Seog-Heon;Han Gunhee
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.1 s.343
    • /
    • pp.65-70
    • /
    • 2006
  • An image sensor has limited dynamic range while the human eye has logarithmic response over wide range of light intensity. Although the sensor gain can be set high to identify details in darker area on the image, this results in saturation in brighter area. The gamma correction is essential to fit the human eye response. However, the digital gamma correction degrades image quality especially for darker area on the image due to the limited ADC resolution and the dynamic range. This Paper proposes a CMOS image sensor (CIS) with a nonlinear analog-to-digital converter (AU) which performs analog gamma correction. The CIS with the proposed nonlinear analog-to-digital conversion scheme was fabricated with a $0.35{\mu}m$ CMOS process. The analog gamma correction using the proposed nonlinear ADC CIS provides the 2.2dB peak-signal-to-noise-ratio(PSM) improved image qualify than conventional digital gamma correction. The PSNR of the image obtain from the digital gamma correction is 25.6dB while it is 27.8dB for analog gamma correction. The PSNR improvement over digital gamma correction is about $28.8\%$.