• Title/Summary/Keyword: dynamic measurement

Search Result 1,890, Processing Time 0.032 seconds

Comparison and Optimization of Flux Chamber Methods of Methane Emissions from Landfill Surface Area (매립지 표면의 메탄 발산량 실측을 위한 플럭스 챔버의 방법론적 비교와 최적화)

  • Jeong, Jin Hee;Kang, Su Ji;Lim, Jong Myoung;Lee, Jin-Hong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.10
    • /
    • pp.535-542
    • /
    • 2016
  • As one of the most cost-effective methods for surface emission measurements, flux chamber method has been used worldwide. It can be classified into two types: SFC (with slope method) and DFC (with steady-state method). SFC (static flux chamber) type needs only simple equipment and is easy to handle. However, the value of flux might vary with SFC method, because it assumes that the change of concentration in chamber is linear with time. Although more specific equipments are required for DFC (dynamic flux chamber) method, it can lead to a constant result without any ambiguity. We made a self-designed DFC using a small and compact kit, which recorded good sample homogeneity (RSD < 5%) and recovery ( > 90%). Relative expanded measurement uncertainty of this improved DFC method was 7.37%, which mainly came from uncontrolled sweep air. The study shows that the improved DFC method can be used to collect highly reliable emission data from large landfill area.

Design and Implementation of Digital Electrical Impedance Tomography System (디지털 임피던스 영상 시스템의 설계 및 구현)

  • 오동인;백상민;이재상;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.269-275
    • /
    • 2004
  • Different biological tissues have different values of electrical resistivity. In EIT (electrical impedance tomography), we try to provide cross-sectional images of a resistivity distribution inside an electrically conducting subject such as the human body mainly for functional imaging. However, it is well known that the image reconstruction problem in EIT is ill-posed and the quality of a reconstructed image highly depends on the measurement error. This requires us to develop a high-performance EIT system. In this paper, we describe the development of a 16-channel digital EIT system including a single constant current source, 16 voltmeters, main controller, and PC. The system was designed and implemented using the FPGA-based digital technology. The current source injects 50KHz sinusoidal current with the THD (total harmonic distortion) of 0.0029% and amplitude stability of 0.022%. The single current source and switching circuit reduce the measurement error associated with imperfect matching of multiple current sources at the expense of a reduced data acquisition time. The digital voltmeter measuring the induced boundary voltage consists of a differential amplifier, ADC, and FPGA (field programmable gate array). The digital phase-sensitive demodulation technique was implemented in the voltmeter to maximize the SNR (signal-to-noise ratio). Experimental results of 16-channel digital voltmeters showed the SNR of 90dB. We used the developed EIT system to reconstruct resistivity images of a saline phantom containing banana objects. Based on the results, we suggest future improvements for a 64-channel muff-frequency EIT system for three-dimensional dynamic imaging of bio-impedance distributions inside the human body.

Study on the Development of Program for Measuring Preference of Portrait based on Sensibility (감성기반 인물사진 선호도 측정 프로그램 개발 연구)

  • Lee, Chang-Seop;Har, Dong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.2
    • /
    • pp.178-187
    • /
    • 2018
  • This study aimed to develop a model of the program for automation measuring the preference of the portraits based on the relationship between the image quality factors and the preferences in the portraits for manufacturers aiming at high utilization of the users. in order to proceed with the evaluation, the image quality measurement was divided into objective and subjective items, and the evaluation was done through image processing and statistical methods. the image quality measurement items can be divided into objective evaluation items and subjective evaluation items. RSC Contrast, Dynamic Range and Noise were selected for the objective evaluation items, and the numerical values were statistically analyzed and evaluated through the program. Exposure, Color Tone, composition of person, position of person, and out of focus were selected for subjective evaluation items and evaluated by image processing method. By applying objective and subjective assessment items, the results were very accurate, with the results obtained by the developed program and the results of the actual visual inspection. but since the currently developed program can be evalua ted only after facial recognition of the person, future research will need to develop a program that can evaluate all kinds of portraits.

Development of High Energy Particle Detector for the Study of Space Radiation Storm

  • Jo, Gyeong-Bok;Sohn, Jongdae;Choi, Cheong Rim;Yi, Yu;Min, Kyoung-Wook;Kang, Suk-Bin;Na, Go Woon;Shin, Goo-Hwan
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.3
    • /
    • pp.277-283
    • /
    • 2014
  • Next Generation Small Satellite-1 (NEXTSat-1) is scheduled to launch in 2017 and Instruments for the Study of Space Storm (ISSS) is planned to be onboard the NEXTSat-1. High Energy Particle Detector (HEPD) is one of the equipment comprising ISSS and the main objective of HEPD is to measure the high energy particles streaming into the Earth radiation belt during the event of a space storm, especially, electrons and protons, to obtain the flux information of those particles. For the design of HEPD, the Geometrical Factor was calculated to be 0.05 to be consistent with the targets of measurement and the structure of telescope with field of view of $33.4^{\circ}$ was designed using this factor. In order to decide the thickness of the detector sensor and the classification of the detection channels, a simulation was performed using GEANT4. Based on the simulation results, two silicon detectors with 1 mm thickness were selected and the aluminum foil of 0.05 mm is placed right in front of the silicon detectors to shield low energy particles. The detection channels are divided into an electron channel and two proton channels based on the measured LET of the particle. If the measured LET is less than 0.8 MeV, the particle belongs to the electron channel, otherwise it belongs to proton channels. HEPD is installed in the direction of $0^{\circ}$, $45^{\circ}$, $90^{\circ}$ against the along-track of a satellite to enable the efficient measurement of high energy particles. HEPD detects electrons with the energy of 0.1 MeV to several MeV and protons with the energy of more than a few MeV. Thus, the study on the dynamic mechanism of these particles in the Earth radiation belt will be performed.

Development of Impact Factor Response Spectrum based on Frequency Response of Both Ends-Fixed Beam for Application to Continuous Bridges (연속교 적용을 위한 양단고정지지 보의 진동수 기반 충격계수 응답스펙트럼 개발)

  • Roh, Hwasung;Lee, Huseok;Park, Kyung-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.301-306
    • /
    • 2016
  • In bridge performance assessments, a new load carrying capacity evaluation model of simple bridges was proposed, which is based on the developed simple support impact factor spectrum. In this paper, a conservative assumption that the inner span with the both ends fixed boundary condition is ideal for applying the impact factor response spectrum for continuous bridges. The impact factor response spectrum has been proposed based on this assumption. The response spectrum by comparing the numerical analysis result and actual measurement data verified the applicability. The analysis was loading the moving load of DB-24 in a six-span continuous bridge, which was the same as the actual measurement data, the dynamic response was measured in the fourth span. The frequency of the bridge was obtained by FFT on the acceleration response and the span-frequency of sample bridge was calculated by the frequency. The impact factor of the sample bridge was determined by applying the span-frequency of the bridge to the proposed response spectrum; it was similar to the result of comparing the actual measured impact factor. Therefore, the method using the impact factor response spectrum based on the frequency response of both ends-fixed beam was found to be applicable to an actual continuous bridge.

A Study of the Influence of illness on Body Image and Self Concept -Specifically in Children with Asthma- (만성 질환이 자아개념 (Self Concept)과 신체상(Body Image)에 미치는 영향 -천식 환아를 중심으로-)

  • 장효순
    • Journal of Korean Academy of Nursing
    • /
    • v.12 no.2
    • /
    • pp.80-90
    • /
    • 1982
  • This study was undertaken to determine the influence of a chronic disease on body image, and to show that body image is directly related to one's self concept. Body image is the concept of one's own body based on present and past perception, and is elated to one's self concept. Body image is a dynamic concept constantly changing throughout the life cycle but it changes greatly in illness, surgery, and accident. The child with a chronic disease experiences pain and immobilization due to illness and he/she experiences a strange environment in the hospital. illness often brings feeling of frustration and loss of self-esteem. Therefore this study was done to compare the body image of a child with a chronic disease(Asthma), with that of a normal healthy child, and to determine the relationship between the body image and self concept. The subjects in this study were 36 children being treated for asthma at the allergy clinic of Y University Hospital in Seoul (patient group) and 44 children attending elementary school in Kwanak Ku Seoul (normal healthy group). For the measurement of the body image, the researcher used Secord & Jourard's Body Cathexis Scale, and another scale which was constructed after reading about Osgood's Semantic Differential Method. For the measurement of the self concept, the researcher used Jacox & Stewart's Health Self Concept. The period for data collection was from October 7th to October 27th, 1982. The analysis of data was done by use of Percentage, t-test, Chi-square test, Pearson Correlation Coefficient and ANOVA, The results of the study were as follows: 1. The first hypothesis,“That the chronically ill (Asthma) child will have a more negative body image than the normal healthy child.”was supported. 2. The second hypothesis,“The more negative the body image, the lower the self concept.”was also supported. 3. The researcher failed to obtain statistically significant results in the analysis of the general characteristics which affect the body image except in the case of the older child as compare to the younger Child having a mole positive body image (r=.2751, r=.2481, p<.05). However it was found that, 1) Boy's have a more positive body image than girls (Mean=〔37.81, 141.09〕,〔37.00, 126.54〕), 2) The child who has been hospitalized has a more negative body image than the child who has never been hospitalized (Mean=〔33.25, 122.45〕,〔35.68, 129.93〕). 3) The younger the child when the disease is discovered and diagnosed, the more negative the body image (Onset of illness: Mean=〔31.44, 117.33〕,〔34.00, 103.50〕, 〔35.75, 140.38〕,〔36.33, 130.00〕, Time of Diagnosis: Mean=〔29.00, 117.33〕,〔33.89, 115.00〕,〔33.36, 124.93〕,〔37.10, 139. 20〕). In conclusion the chronically ill(.Asthma) child has a more negative body image than the normal healthy child, and the more negative the body image the lower the self concept. Therefore the concept of body image is useful in understanding the influences of chronic disease on body' image and self concept.

  • PDF

Interfacial Control of Multi-functional CNT and ITO/PET Nanocomposites having Self-Sensing and Transparency (자체-감지능 및 광투과도를 지닌 CNT 및 ITO/PET 다기능성 나노복합소재의 계면 조절 연구)

  • Wang, Zuo-Jia;Kwon, Dong-Jun;Gu, Ga-Young;Park, Joung-Man
    • Composites Research
    • /
    • v.24 no.1
    • /
    • pp.45-50
    • /
    • 2011
  • Transparent and conductive carbon nanotube on polyethylene terephthalate (PET) were prepared by dip-coating method for self-sensing multi-functional nanocomposites. The changes in the electrical and optical properties of CNT coating mainly depended on the number of dip-coating, concentration of CNT solution. Consequently, the surface resistance and transmittance of CNT coating were sensitively controlled by the processing parameters. Surface resistance of CNT coating was measured using four-point method, and surface resistance of coated CNT could be better calculated by using the dual configuration method. Optical transmittance of PET film with CNT coating was evaluated using UV spectrum. Surface properties of coated CNT investigated by wettability test via static and dynamic contact angle measurement were consistent with each other. As dip-coating number increased, surface resistance of coated CNT decreased seriously, whereas the transmittance exhibited little lower due to the thicker CNT networks layer. Interfacial microfailure properties were investigated for CNT and indium tin oxide (ITO) coatings on PET substrates by electrical resistance measurement under cyclic loading fatigue test. CNT with high aspect ratio exhibited no change in surface resistance up to 2000 cyclic loading, whereas ITO with brittle nature showed a linear increase of surface resistance up to 1000 cyclic loading and then exhibited the level-off due to reduced electrical contact points based on occurrence of many micro-cracks.

Development of Intelligent Multiple Camera System for High-Speed Impact Experiment (고속충돌 시험용 지능형 다중 카메라 시스템 개발)

  • Chung, Dong Teak;Park, Chi Young;Jin, Doo Han;Kim, Tae Yeon;Lee, Joo Yeon;Rhee, Ihnseok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.9
    • /
    • pp.1093-1098
    • /
    • 2013
  • A single-crystal sapphire is used as a transparent bulletproof window material; however, few studies have investigated the dynamic behavior and fracture properties under high-speed impact. High-speed and high-resolution sequential images are required to study the interaction of the bullet with the brittle ceramic materials. In this study, a device is developed to capture the sequence of high-speed impact/penetration phenomena. This system consists of a speed measurement device, a microprocessor-based camera controller, and multiple CCD cameras. By using a linear array sensor, the speed-measuring device can measure a small (diameter: up to 1 2 mm) and fast (speed: up to Mach 3) bullet. Once a bullet is launched, it passes through the speed measurement device where its time and speed is recorded, and then, the camera controller computes the exact time of arrival to the target during flight. Then, it sends the trigger signal to the cameras and flashes with a specific delay to capture the impact images sequentially. It is almost impossible to capture high-speed images without the estimation of the time of arrival. We were able to capture high-speed images using the new system with precise accuracy.

Development of MATLAB GUI Based Software for Generating GPS RINEX Observation File (MATLAB GUI 기반 GPS RINEX 관측 파일 생성 소프트웨어의 개발)

  • Kim, Dong-uk;Yun, Ho;Han, Deok-hwa;Jang, Joo-young;Kee, Chang-don;So, Hyoung-min;Lee, Ki-hoon;Jang, Jae-gyu
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.4
    • /
    • pp.299-304
    • /
    • 2015
  • This paper introduces development of the MATLAB GUI based software for generating GPS RINEX observation file. The purpose of this software is to generate GPS measurements of reference station or dynamic user, which are similar to the real GPS receiver data, accurately and efficiently. This software includes two data generation modes. One is Precision mode which generates GPS measurements as accurate as possible using post-processing data. The other is Real-time mode which generates GPS measurements using GPS error modeling technique. GPS error sources are calculated on the basis of each data generation mode, and L1/L2 pseudorange, L1/L2 carrier phase, and Doppler measurements are produced. These generated GPS measurements are recorded in the RINEX observation version 3.0 file. Using received GPS data at real reference station, we analyzed three items to verify software reliability; measurement bias, rate of change, and noise level. Consequently, RMS error of measurement bias is about 0.7 m, and this verification results demonstrate that our software can generate relatively exact GPS measurements.

The Imbalance Compensation in CMG ('제어모멘트자이로'의 질량불균형 보정)

  • Lee, Jong-Kuk;Song, Tae-Seong;Kang, Jeong-Min;Song, Deok-Ki;Kwon, Jun-Beom;Seo, Joong-Bo;Oh, Hwa-Suk;Cheon, Dong-Ik;Hong, Young-Gon;Lee, Jun-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.11
    • /
    • pp.861-871
    • /
    • 2020
  • Raising the speed of the momentum wheel in the CMG increases the unintended force and torque caused by mass imbalance. This unintended force and torque should be minimized to get the better quality of satellite SAR image because they lead to the vibration of the output image. This paper shows the works on compensating the static imbalance and couple mass imbalance in the CMG wheel. First, the force and torque at the center of mass generated by the mass imbalance were predicted through M&S analysis. Second, the force and torque were estimated similarly through the M&S analysis when the measurement point was moved from the rotation center. Third, the measurement configuration for the force and torque by the mass imbalance was described. Fourth, the change of the force and torque by adding the specified mass to the momentum wheel was observed after comparing the measurements with the results of the M&S. And finally, the effect of the compensation was analyzed by comparing the force and torque before and after the correction while 24Nm class CMG was running in the standby mode.