• Title/Summary/Keyword: dynamic head

Search Result 508, Processing Time 0.03 seconds

The Analysis of Dynamic Foot Pressure on Difference of Functional Leg Length Inequality (기능적 하지길이 차이에 따른 동적 족저압의 분석)

  • Gong, Won-Tae;Kim, Joong-Hwi;Kim, Tae-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.4
    • /
    • pp.43-49
    • /
    • 2009
  • Purpose: This study examined the dynamic peak plantar pressure under the foot areas in those with a functional leg length inequality. Methods: The dynamic peak plantar pressure under the foot areas in an experimental group with a functional leg length inequality (n=20) and a control group (n=20) was assessed a using the Mat-Scan system (Tekscan, USA). The peak plantar pressure under the hallux, 1st, 2nd, 3-4th and 5th metatarsal head (MTH), mid foot, and heel was measured while the subject was walking on the Mat-Scan system. Results: The experimental group had significantly higher peak plantar pressure under all foot areas when the dynamic peak plantar pressure in the short leg and long leg sides was compared. The control group had a significantly higher peak plantar pressure under the 1st, 2nd, 3-4th, and 5th MTH when the dynamic peak plantar pressure in the short leg and long leg sides were compared. The experimental group showed a significantly larger difference in the dynamic peak plantar pressure under the hallux, 1st, 2nd, 3-4th and 5th MTH, mid foot and heel than the control group. Conclusion: A functional leg length inequality leads to an increase in the weight distribution and dynamic peak plantar pressure in the side of the short leg.

  • PDF

A STUDY ON THE APPLICATION OF DYNAMIC TOMOGRAM OF THE HUMAN HEAD (인체 두부에서 Dynamic Tomogram의 응용에 관한 연구)

  • Choi Eui Whan;Kim Jae Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.2
    • /
    • pp.317-326
    • /
    • 1991
  • The purpose of this study was to establish the principle and the clinical application of dynamic tomogram of a human head by using the dental machine. For this study, a block of wax with details lying at three parallel planes and a human dry skull were used. This experiment was reexamined the dynamic tomogram with specialized radiographic device and view box, and the radiograms taken by the change of exposure time according to the numbers of film used in x-ray taking and taken according to the change of kVp and the types of film were analyzed density with the densitometer. From this study, the obtained results were as follows: 1. When the underexposed radiograms taken by angulation of clockwise and counter-clockwise direction of the film and skull. were superimposed and moved laterally, it was possible to focus on right and left jaws and teeth. 2. The superimposition of the two underexposed radiograms according to each condition of x-ray taking showed some differencies in density visually, and the measurement of density with the densitometer was 1.23 to 1.57 in 75kVp and 1.34 to 1.70 in 90kVp. 3. The superimposition of the two underexposed radiograms according to the kinds of x-ray film showed almost equal density visually, and the measurement of density with the densiometer was 1.34 to 1.37. 4. When seven radiograms taken by each condition of x-ray taking were superimposed on the view box, a intense rear light of view box didn't transilluminate film density regardless of the conditions of x-ray taking. Even though seven radiograms taken according to types of film were superimposed on the view box, a more intense rear light of view box was required to transilluminate total density of films. 6. Long film-object distance resulted in the enlargement and blurring of radiographic images.

  • PDF

Fluid-Structure Interaction Study on Diffuser Pump With a Two-Way Coupling Method

  • Xu, Huan;Liu, Houlin;Tan, Minggao;Cui, Jianbao
    • International Journal of Fluid Machinery and Systems
    • /
    • v.6 no.2
    • /
    • pp.87-93
    • /
    • 2013
  • In order to study the effect of the fluid-structure interaction (FSI) on the simulation results, the external characteristics and internal flow features of a diffuser pump were analyzed with a two-way flow solid coupling method. And the static and dynamic structure analysis of the blade was also caculated with the FEA method. The steady flow field is based on Reynolds Averaged N-S equations with standard $k-{\varepsilon}$ turbulent model, the unsteady flow field is based on the large eddy simulation, and the structure response is based on elastic transient structural dynamic equation. The results showed that the effect of FSI on the head prediction based on CFD really exists. At the same radius, the van mises stress on the nodes closed shroud and hub was larger than other nodes. A large deformation region existed near inlet side at the middle of blades. The strength of impeller satisfied the strength requirement with static stress analysis based on the fourth strength theory. The dynamic stress varied periodically with the impeller rotating. It was also found that the fundamental frequency of the dynamic stress is the rotating frequency and its harmonic frequency. The frequency of maximum stress amplitude at node 1626 was 7 times of the rotating frequency. The frequency of maximum stress amplitude at node 2328 was 14 times of the rotating frequency. No matter strength failure or fatigue failure, the root of blades near shroud is the key region to analyse.

A clustering algorithm based on dynamic properties in Mobile Ad-hoc network (에드 혹 네트워크에서 노드의 동적 속성 기반 클러스터링 알고리즘 연구)

  • Oh, Young-Jun;Woo, Byeong-Hun;Lee, Kang-Whan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.3
    • /
    • pp.715-723
    • /
    • 2015
  • In this paper, we propose a context-awareness routing algorithm DDV (Dynamic Direction Vector)-hop algorithm in Mobile Ad Hoc Networks. The existing algorithm in MANET, it has a vulnerability that the dynamic network topology and the absence of network expandability of mobility of nodes. The proposed algorithm performs cluster formation using a range of direction and threshold of velocity for the base-station, we calculate the exchange of the cluster head node probability using the direction and velocity for maintaining cluster formation. The DDV algorithm forms a cluster based on the cluster head node. As a result of simulation, our scheme could maintain the proper number of cluster and cluster members regardless of topology changes.

An Efficient Clustering Protocol with Mode Selection (모드 선택을 이용한 효율적 클러스터링 프로토콜)

  • Aries, Kusdaryono;Lee, Young Han;Lee, Kyoung Oh
    • Annual Conference of KIPS
    • /
    • 2010.11a
    • /
    • pp.925-928
    • /
    • 2010
  • Wireless sensor networks are composed of a large number of sensor nodes with limited energy resources. One critical issue in wireless sensor networks is how to gather sensed information in an energy efficient way since the energy is limited. The clustering algorithm is a technique used to reduce energy consumption. It can improve the scalability and lifetime of wireless sensor network. In this paper, we introduce a clustering protocol with mode selection (CPMS) for wireless sensor networks. Our scheme improves the performance of BCDCP (Base Station Controlled Dynamic Clustering Protocol) and BIDRP (Base Station Initiated Dynamic Routing Protocol) routing protocol. In CPMS, the base station constructs clusters and makes the head node with highest residual energy send data to base station. Furthermore, we can save the energy of head nodes using modes selection method. The simulation results show that CPMS achieves longer lifetime and more data messages transmissions than current important clustering protocol in wireless sensor networks.

Settling time of dental x-ray tube head after positioning (치과용 X-선 관구의 조정시간)

  • Yoon Suk-Ja;Kang Byung-Cheol;Wang Se-Myung;Koh Chang-Sung
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.159-165
    • /
    • 2002
  • Purpose: The aim of this study was to introduce a method of obtaining the oscillation graphs of the dental x-ray tube heads relative to time using an accelerometer. Materials and Methods: An Accelerometer, Piezotron type 8704B25 (Kistler Instrument Co., Amherst, NY, USA) was utilized to measure the horizontal oscillation of the x-ray tube head immediately after positioning the tube head for an intraoral radiograph. The signal from the sensor was transferred to a dynamic signal analyzer, which displayed the magnitude of the acceleration on the Y-axis and time lapse on the X -axis. The horizontal oscillation of the tube head was measured relative to time, and the settling time was also determined on the basis of the acceleration graphs for 6 wall type, 5 floor-fixed type, and 4 mobile type dental x-ray machines. Results : The oscillation graphs showed that tube head movement decreased rapidly over time. The settling time varied with x-ray machine types. Wall-type x-ray machines had a settling time of up to 6 seconds, 5 seconds for fixed floor-types, and 1 I seconds for the mobile-types. Conclusion: Using an accelerometer, we obtained the oscillation graphs of the dental x-ray tube head relative to time. The oscillation graph with time can guide the operator to decide upon the optimum exposure moment after x-ray tube head positioning for better radiographic resolution.

  • PDF

Effects of Kinesio Taping on Craniovertebral Angle and Balance Ability in Subject with Forward Head Posture

  • Jeon, Yong-Jin;Kim, Gyoung-Mo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.8
    • /
    • pp.145-150
    • /
    • 2020
  • Forward head posture is one of the most recognized types of poor head and neck alignment. Poor head and neck alignment posture is a major contributor to compromised balance and neck pain, due to abnormal joint position sense and proprioception. Kinesio taping is an intervention method used clinically for the management of pain. Kinesio taping may produce its effects through pain reduction, stimulation of blood circulation, induction of muscle relaxation which provides correction of joint position, and providing stability to the muscles and joints without limiting the range of motion. Many studies have proved that kinesio taping has positive effects on the reduction of pain and improves alignment, on the other hand, some studies have not found. Kinesio taping may provide immediate pain relief and improved alignment following the application, but there is insufficient evidence to support sustained relief beyond that time and they recommended future studies to examine the benefits of kinesio taping as this would have a greater value in clinical practice. Therefore, this study is to investigate the effects of kinesio taping on the alignment of head posture and dynamic balance ability in people with forward head posture.

Design and Optimization of Suspension with Optical Flying Head Using Integrated Optimization Frame (통합최적프레임을 사용한 광부상헤드를 탑재한 서스팬션의 최적화)

  • Kim, Ji-Won;Park, Kyoung-Su;Yoon, Sang-Joon;Choi, Dong-Hoon;Park, Young-Pil;Lee, Jong-Soo;Park, No-Cheol
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.2
    • /
    • pp.161-168
    • /
    • 2005
  • This paper optimizes the optical flying head(OFH) suspension using the integrated optimization frame, which automatically integrates the analysis with the optimization and effectively implements the repetitive works between them. The problem formulation for the optimization is suggested to improve the dynamic compliance of OFH and to shift the resonant frequencies caused tracking errors to high frequency domain. Furthermore, the minimization of the effective suspension mass that leads to decrease the so-called 'lift-off' as the disk-head separation acceleration divided by the suspension load is taken into consideration. In particular, this study is carried out the optimal design considering the process of modes tracking through the entire optimization processes. The advanced suspension that reduces the effective mass of the suspension and increases the resonant frequencies of sway and $2^{nd}$ torsion over 10kHz is achieved by using the integrated optimization frame.

  • PDF

The Effects of Neck Exercise Program for Smart Phone-Addicts with Forward Head Posture on Cervical Alignment and Balance Ability (전방두부자세를 가진 스마트폰중독자를 위한 경부운동 프로그램이 경부정렬과 신체균형에 미치는 영향)

  • Kong, Bukyung;Kwon, Minsung;Lee, Geoncheol;Yang, Giung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.1 no.2
    • /
    • pp.81-92
    • /
    • 2013
  • Purpose : This research was carried out to find how neck exercise program combined with self stretching and muscle strengthening program influences on smart phone addicts with forward head posture. Methods : The subjects of this study were 20 smart phone-addicts with forward head posture and we divided them into 2 groups. The experimental group(10 people) participated in neck exercise program as a intervention for 3 months and the control group(the other 10 people) didn't participate in neck exercise program. Neck exercise program were composed of self stretching and muscle strengthening program. Then we measured cervical alignment with GPS(Global Posture System) and evaluated balance ability with Balance Master ver 7.0 systems. Results : The result were as follows. 1. After the intervention, experimental group were significantly more closed to normal cervical alignment than control group. 2. After the intervention, experimental group increased in dynamic balance ability a little more than control group. Conclusion : Neck exercise program seems to get cervical alignment better and improve balance ability.

Segmentation and Visualization of Head MR Image Based on Structural Approach (구조적인 기법을 이용한 머리 MR 단층 영상의 조직 분류 및 가시화)

  • 권오봉;김민기
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.3
    • /
    • pp.283-290
    • /
    • 1999
  • Because MR(Magnetic Resonance) slice images have much information of functions about body organs, it is very effeclive for diagnoses lo analyze and visualize MR slice images. A visuahzation process is composed of medical image acquisition, preprocessmg, segmentation, inlerpolation, rendering. Segmentation and interpolation among thenl ,1re currenl hot topics because of MR slice image imperfections. This paper proposes a method for segmentalion, mlerpolation respectively and addresses 3 D-visualizmg of a head. We segmented head tissues uomg otructural knowledge of head studied by clinical experiments sequentially. We improved the dynamic elastic inlerpolation to Utilize in concave conlour. We compared the proposed segmentation method and the interpolation method with other methods.

  • PDF