• Title/Summary/Keyword: dynamic absorber

Search Result 191, Processing Time 0.026 seconds

Hydropneumatic Modeling and Dynamic Characteristic Analysis of a Heavy Truck Semi-active Cabin Air Suspension System (대형 트럭 반능동형 캐빈 공기 현가시스템의 유공압 모델링 및 동특성 해석)

  • Lee, Kwang-Heon;Jeong, Heon-Sul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.2
    • /
    • pp.57-65
    • /
    • 2011
  • In this paper, a hydropneumatic modeling and dynamic analysis of a heavy truck semi-active cabin air suspension system is presented. Semi-active cabin air suspension system improves driver's ride comfort by controlling the damping characteristics in accordance with driving situation. So it can reduce vibration between truck frame and cabin. Semi-active cabin air suspension system is consist of air spring, leveling valve and CDC shock absorber, and full cabin system are mathematically modelled using AMESim software. Simulation results of components and full cabin system are compared with experimental data of components and test results of a cabin using 6 axis simulation table. It is found that the simulation results are in good agreements with test results, and the hydropneumatic model can be used well to predict dynamic characterics of heavy truck semi-active cabin air suspension system.

Development of Dynamic Vibration Absorber to Reduce Unbalance Response in Flexible Rotor-Bearing System (탄성 회전체 베어링 계의 불균형 응답 저감을 위한 동흡진기 개발)

  • Yu, Tae-Gyu;Bae, Gyu-Hyun;Kim, Kil-Hwan;Hong, Seong-Wook
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.1
    • /
    • pp.175-181
    • /
    • 2012
  • This paper presents a novel dynamic vibration absorber (DVA) to suppress the unbalance response of flexible rotor-bearing systems. The DVA unit consists of two DVAs, an adapter to place the DVAs and an adapter frame to locate the adapter. The essential feature of the proposed DVA unit is to place itself on any desirable location of the shaft without disassembling the rotor-bearing system under consideration. A simulation with a 3D element based commercial rotor dynamic software is made to test the possibility of the proposed DVA on the suppression of unbalance response in rotor-bearing systems. Experiments are performed to validate the proposed DVA unit. The simulation and experiments show that the proposed DVA unit is very effective to suppress the unbalance response in rotor-bearing system at designated rotational speeds of interest.

On the Normal Mode Dynamics of a Pendulum Absorber (정규모우드 방법을 활용한 진자형 흡진기의 비선형 동역학에 관한 연구)

  • 심재구;박철희
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.177-183
    • /
    • 1996
  • By utilizing the concept of normal modes, nonlinear dynamics is studied on pendulum dynamic absorber. When the spring mode loses the stability in undamped free system, a dynamic two-well potential is formed in Poincare map. A procedure is formulated to compute the forced responses associated with bifurcating mode and predict double saddle-loop phenomenon. It is found that quasiperiodic motion and stable periodic motion coexist in some parameter ranges, and only periodic motions or rotation of pendulum with chaotic fluctuation are observed in other ranges.

  • PDF

A study on the dynamic vibration absorber having non-linear spring and linear damper (非線型 스프링과 線型감쇠를 가지는 動吸振器에 관한 硏究)

  • 김광식;안찬우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.3
    • /
    • pp.473-478
    • /
    • 1987
  • In this paper the optimum values of natural frequency ratio and damping ratio for damped systems were studied by numerical analysis. The relation between the amplitude ratio and frequency ratio obtained for the non-linear dynamic vibration absorber was found and it was compared with that of linear system. The results shows that the optimum frequency ratio decreases and the optimum damping ratio increases when the mass ratio of the damped system increases. The resonance frequency ratio and amplitude ratio decrease as mass ratio increases for the non-linear spring system.

Isolating Vibration in Miniature Linear Cryogenic Cooler with Tuned Vibration Absorber (동조질량 진동흡수기를 이용한 미니 저온쿨러의 진동 절연)

  • Kim, Young-Keun;Kim, Hong-Bae;Kim, Eung-Hyun;Kim, Kyung-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.5
    • /
    • pp.605-609
    • /
    • 2010
  • In modern surveillance equipment, infrared (IR) sensors are essential for detection and observation. The IR sensor is connected to a miniature cryogenic cooler to maintain the temperature at very low levels, i.e., temperatures as low as 77 K. However, the quality of the image captured by the sensor is degraded by the transmission of vibration disturbances from the cooler. Therefore, to maintain high image quality, the compressor vibration and the force transmitted to the sensor have to be mitigated. For the compressor vibration isolating system, a tuned dynamic vibration absorber, combined with a passive isolator, is proposed. A cryogenic compressor bracket and springs are designed to allow the absorber mass to mitigate the vibration jitter in the axial direction. The system design is analyzed and evaluated in terms of the dynamic suppression of the harmonic force at the operating frequency of the cooler.

Optimal Design Method of Dynamic Vibration Absorber to Reduce Resonant Vibration Response of Ship Local Structure (선박 국부구조의 공진응답 저감을 위한 동흡진기 최적 설계 방법)

  • Kwon, Hyuk;Cho, Daeseung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.3
    • /
    • pp.134-140
    • /
    • 2022
  • Ship local structure sometimes experiences severe vibration due to the resonance with an excitation force generated by the propulsion system. In that case, the installation of dynamic vibration absorber such as Tuned Mass Damper (TMD) on the structure can be considered as an effective alternative countermeasure to reduce the troublesome vibration if structural modification or change of excitation frequencies is difficult. Meanwhile, the conventional optimal design method of TMD premises the target structure exposed on an excitation force without the constraint of its magnitude and frequency range. However, the frequencies of major ship excitation forces due to propulsion system are normally bounded and its magnitude is varied according to its operation speed. Hence, the optimal design of TMD to reduce the resonant vibration of ship local structure should be differently approached compared with the conventional ones. For the purpose, this paper proposes an optimal design method of TMD considering maximum frequency and magnitude variation of a target harmonic excitation component. It is done by both lowering the resonant response at the 1st natural frequency and locating the 2nd natural frequency over maximum excitation frequency for the idealized 2 degree of freedom system consisted of the structure and the TMD. For the validation of the proposed method, a numerical design case of TMD for a ship local structure exposed on resonant vibration due to a propeller excitation force is introduced and its performance is compared with the conventionally designed one.

Evaluations of the Acoustics Characteristics of Cellulose Absorbers (셀룰로오즈 흡음재의 음향적 특성 평가)

  • Yeon, Joon-Oh;Kim, Kyoung-Woo;Yang, Kwan-Seop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.5
    • /
    • pp.456-462
    • /
    • 2013
  • Eco-friendly material applied to building would be one of the materials which is must developed for global environmental conservation and reduction of carbon dioxide. For development of eco-friendly material, a cellulose absorber has been developed with waste paper through adjustment of various mix proportions. The developed cellulose absorber has been tested for its acoustic properties such as absorption coefficient and dynamic stiffness. The absorption coefficient was evaluated by developing six samples and using impedance tube and reverberation chamber. As a result of the evaluation, 0.64(NRC) was secured in absorption coefficient and 4.7 $MN/m^3$ was indicated in dynamic stiffness. Also, for practical use of developed absorbers as inner heartwood in drywall, comparison test of sound reduction index was performed with existing glass wool absorbers and constructed drywall of gypsum board. The results have shown 55 dB(Rw) of sound reduction index in glass-wool wall and 46 dB(Rw) in cellulose.