• 제목/요약/키워드: dynamic CT

검색결과 152건 처리시간 0.023초

Dynamic CT Myocardial Perfusion Imaging in Patients without Obstructive Coronary Artery Disease: Quantification of Myocardial Blood Flow according to Varied Heart Rate Increments after Stress

  • Lihua Yu;Xiaofeng Tao;Xu Dai;Ting Liu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • 제22권1호
    • /
    • pp.97-105
    • /
    • 2021
  • Objective: The present study aimed to investigate the association between myocardial blood flow (MBF) quantified by dynamic CT myocardial perfusion imaging (CT-MPI) and the increments in heart rate (HR) after stress in patients without obstructive coronary artery disease. Materials and Methods: We retrospectively included 204 subjects who underwent both dynamic CT-MPI and coronary CT angiography (CCTA). Patients with more than minimal coronary stenosis (diameter ≥ 25%), history of myocardial infarction/revascularization, cardiomyopathy, and microvascular dysfunction were excluded. Global MBF at stress was measured using hybrid deconvolution and maximum slope model. Furthermore, the HR increments after stress were recorded. Results: The median radiation dose of dynamic CT-MPI plus CCTA was 5.5 (4.5-6.8) mSv. The median global MBF of all subjects was 156.4 (139.8-180.4) mL/100 mL/min. In subjects with HR increment between 10 to 19 beats per minute (bpm), the global MBF was significantly lower than that of subjects with increment between 20 to 29 bpm (153.3 mL/100 mL/min vs. 171.3 mL/100 mL/min, p = 0.027). This difference became insignificant when the HR increment further increased to ≥ 30 bpm. Conclusion: The global MBF value was associated with the extent of increase in HR after stress. Significantly higher global MBF was seen in subjects with HR increment of ≥ 20 bpm.

64-절편 다행검출 CT 검사에서의 환자선량과 암 발생의 Lifetime Attributable Risk(LAR) 평가 (Radiation dose and Lifetime Attributable Risk of Cancer Estimates in 64-slice Multidetector Computed Tomography)

  • 강영한;박종삼
    • 한국콘텐츠학회논문지
    • /
    • 제11권4호
    • /
    • pp.244-252
    • /
    • 2011
  • 본 연구는 임상에서 시행되고 있는 64 절편 다행검출 CT(MDCT)의 방사선량에 대해 알아보고 이 선량으로 인한 암 발생의 잠재적 위험(LAR)을 정량화하고자 하였다. CT 검사의 선량길이곱과 유효선량을 측정하였고, 이로 인한 암 발생 귀속위험은 미국 전리방사선의 생물학적효과 위원회 7차보고서를 이용하였다. 결과에서 두부 CT의 유효선량은 1.48mSv, 흉부 CT(조영제 포함)의 유효선량은 7.66mSv였으며, 복부 역동적 CT는 24.52mSv였다. 두부 CT의 LAR은 남성 7463명 중 1명, 여성 4926명 중 1명이었고, 흉부 CT(조영제포함)의 LAR은 남성 1449명 중 1명, 여성 952명 중 1명이었으며, 복부 역동적 CT는 남성 453명 중 1명, 여성 298명 중 1명이었다. 따라서 64 절편 MDCT 검사는 암발생위험과 무시할 수 없는 관련성이 있었고, 선량을 줄이기 위해 프로토콜 등을 조정하는 등의 세심한 노력을 기울여야 한다.

토끼 뇌감염 모델의 CT 소견과 조영제 주입 후 동맥혈의 Hounsfield Unit의 변화 (CT Scan Findings of Rabbit Brain Infection Model and Changes in Hounsfield Unit of Arterial Blood after Injecting Contrast Medium)

  • 하본철;곽병국;정지성
    • 한국콘텐츠학회논문지
    • /
    • 제12권9호
    • /
    • pp.270-279
    • /
    • 2012
  • 토끼 뇌에 대장균을 주입하여 CT 소견을 알아보고, 시간에 따른 동맥혈의 하운스필드 값의 변화를 알아보고자 하였다. 토끼 두개관에 천두공(burr hole)을 뚫고 2~3 mm 깊이에 대장균 $1{\times}10^7$ CFU/ml, 0.1 ml을 주입하여 뇌염증 모델을 제작하고, 조영 증강 CT와 동적 CT, 그리고 동맥혈의 CT영상을 얻었다.조영 증강 CT에서 뇌농양, 뇌실염 그리고 뇌막염등 다양한 뇌염증 소견이 보였다. 뇌농양은 중앙부가 거의 조영되지 않고 주변부가 강하게 조영되는 전형적인 양상을 보였고, 뇌실염은 측뇌실 벽을 따라 강하게 조영되는 소견을 보였으며, 뇌막염은 종뇌와 간뇌의 접히는 부위 뇌막이 강하게 조영되었다. 동적 CT영상에서 염증 중앙부의 조영제 주입 전 HU 값은 $31.01{\pm}3.55$였고, 주입 후 10분까지 $40.36{\pm}3.76$으로 서서히 증가하였다. 그리고 염증 가장자리구역에서 HU 값은 조영제 주입 전에 $47.23{\pm}3.12$였고, 조영제 주입 후 약 45초에 $63.59{\pm}3.31$로 가장 많이 증가 하였으나 이후 20분까지 약간 떨어졌다. 또한 균 주입 반대쪽 정상 뇌조직에서 측정한 HU 값은 조영제 주입 전에 $39.01{\pm}3.24$이었고, 조영제 주입 후 약 30초에 $49.01{\pm}4.29$로 가장 많이 조영되었고, 이후 서서히 낮아졌다. 동맥 혈액 CT에서 조영제 주입 전 HU 값은 $87.78{\pm}6.88$이었고, 조영제 주입 후 10초부터 30초까지 급격히 증가하여 $749.13{\pm}98.48$로 최대값을 보이고, 30초부터 45초까지 $467.85{\pm}62.98$로 급격히 감소하며, 45초에서 60초까지는 정체기(plateau)를 보였으며, 이후 20분까지 $188.28{\pm}25.03$으로 감소되었다. 결과적으로 대장균으로 뇌염증 모델을 만들 수 있고, 조영 증강 CT를 통하여 뇌염증의 특징적인 소견을 잘 알 수 있었으며, 동적 CT를 통해 염증 중앙부와 가장자리구역의 조영 양상을 알 수 있고, 동맥혈은 조영제 주입 후 10초부터 30초 까지 급격히 증가하다 정체기를 거쳐 서서히 감소하는 것으로 나타났다.

Basic Performance Evaluation of the First Model of 4-Dimensional CT-Scanner

  • Mori, Shinichiro;Endo, Masahiro;Tsunoo, Takanori;Kandatsu, Susumu;Tanada, Shuzi;Aradate, Hiroshi;Saito, Yasuo;Miyazaki, Hiroaki;Satoh, Kazumasa;Matsusita, Satoshi;Kusakabe, Masahiro
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.376-378
    • /
    • 2002
  • This work was carried out to evaluate the basic performances for 4D CT, which employed continuously rotating conebeam. The performances were evaluated with the same method as the conventional CT, because the standard method of evaluating 4D CT has not yet been established, and we think this result was helpful to establish it. 4D CT can give dynamic volume imaging data continuously and with high-speed. The results were isotropic except for the evaluation of distortion in which small distortions gradually appeared as coming off the center of phantom in longitudinal direction.

  • PDF

3D 동영상획득을 위한 Cone-Beam 형 X-Ray CT 시스템 구현에 관한 연구 (The Study on the Implementation of the X-Ray CT System Using the Cone-Beam for the 3D Dynamic Image Acquisition)

  • 정찬웅;전계석
    • 한국음향학회지
    • /
    • 제28권4호
    • /
    • pp.370-374
    • /
    • 2009
  • 본 논문에서는 3차원 동영상을 구현하기 위하여 인체에 유해한 방사능 피폭량이 부챗살 형태의 Fan Beam 보다 상대적으로 적은 원추형 Cone Beam CT 시스템을 설계하였다. 설계된 시스템은 X-ray가 조사된 각도에서 획득한 데이터를 영상처리부로 전송하고 영상을 구성하는 계산 속도를 빠르게 하기 위하여 초월함수가 보다 적은 3단계 회전 행렬을 이용하여 3차원 영상을 구현하는 회전 기반법을 사용하였다. 본 연구에서는 3차원 영상을 구성하는 시간단축을 통해 초당 3~5장의 영상을 얻음으로써 3차원 동영상을 실시간으로 구현하였다.

Myocardial Blood Flow Quantified by Low-Dose Dynamic CT Myocardial Perfusion Imaging Is Associated with Peak Troponin Level and Impaired Left Ventricle Function in Patients with ST-Elevated Myocardial Infarction

  • Jingwei Pan;Mingyuan Yuan;Mengmeng Yu;Yajie Gao;Chengxing Shen;Yining Wang;Bin Lu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • 제20권5호
    • /
    • pp.709-718
    • /
    • 2019
  • Objective: To investigate the association of myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) with troponin level and left ventricle (LV) function in patients with ST-segment elevated myocardial infarction (STEMI). Materials and Methods: Thirty-five STEMI patients who successfully had undergone reperfusion treatment within 1 week of their infarction were consecutively enrolled. All patients were referred for dynamic CT-MPI. Serial high-sensitivity troponin T (hs-TnT) levels and left ventricular ejection fraction (LVEF) measured by echocardiography were recorded. Twenty-six patients with 427 segments were included for analysis. Various quantitative parameters derived from dynamic CT-MPI were analyzed to determine if there was a correlation between hs-TnT levels and LVEF on admission and again at the 6-month mark. Results: The mean radiation dose for dynamic CT-MPI was 3.2 ± 1.1 mSv. Infarcted territories had significantly lower MBF (30.5 ± 7.4 mL/min/100 mL versus 73.4 ± 8.1 mL/min/100 mL, p < 0.001) and myocardial blood volume (MBV) (2.8 ± 0.9 mL/100 mL versus 4.2 ± 1.1 mL/100 mL, p = 0.044) compared with those of reference territories. MBF showed the best correlation with the level of peak hs-TnT (r = -0.682, p < 0.001), and MBV showed a moderate correlation with the level of peak hs-TnT (r = -0.437, p = 0.026); however, the other parameters did not show any significant correlation with hs-TnT levels. As for the association with LV function, only MBF was significantly correlated with LVEF at the time of admission (r = 0.469, p = 0.016) and at 6 months (r = 0.585, p = 0.001). Conclusion: MBF quantified by dynamic CT-MPI is significantly inversely correlated with the level of peak hs-TnT. In addition, patients with lower MBF tended to have impaired LV function at the time of their admission and at 6 months.

Hepatic Cavernous Hemangioma in Cirrhotic Liver: Imaging Findings

  • Jeong-Sik Yu;Ki Whang Kim;Mi-Suk Park;Sang-Wook Yoon
    • Korean Journal of Radiology
    • /
    • 제1권4호
    • /
    • pp.185-190
    • /
    • 2000
  • Objective: To document the imaging findings of hepatic cavernous hemangioma detected in cirrhotic liver. Materials and Methods: The imaging findings of 14 hepatic cavernous hemangiomas in ten patients with liver cirrhosis were retrospectively analyzed. A diagnosis of hepatic cavernous hemangioma was based on the findings of two or more of the following imaging studies: MR, including contrast-enhanced dynamic imaging (n = 10), dynamic CT (n = 4), hepatic arteriography (n = 9), and US (n = 10). Results: The mean size of the 14 hepatic hemangiomas was 0.9 (range, 0.5-1.5) cm in the longest dimension. In 11 of these (79%), contrast-enhanced dynamic CT and MR imaging showed rapid contrast enhancement of the entire lesion during the early phase, and hepatic arteriography revealed globular enhancement and rapid filling-in. On contrast-enhanced MR images, three lesions (21%) showed partial enhancement until the 5-min delayed phases. US indicated that while three slowly enhancing lesions were homogeneously hyperechoic, 9 (82%) of 11 showing rapid enhancement were not delineated. Conclusion: The majority of hepatic cavernous hemangiomas detected in cirrhotic liver are small in size, and in many, hepatic arteriography and/or contrast-enhanced dynamic CT and MR imaging demonstrates rapid enhancement. US, however, fails to distinguish a lesion of this kind from its cirrhotic background.

  • PDF

급성 뇌졸중 환자의 시공간 분석 기법을 이용한 동적 전산화 단층 검사: 예비 연구 (Dynamic Computed Tomography based on Spatio-temporal Analysis in Acute Stroke: Preliminary Study)

  • 박하영;편도영;김다혜;정영진
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권4호
    • /
    • pp.543-547
    • /
    • 2016
  • 급성 뇌졸중(acute stroke)의 경우 빠른 처치가 이루어지지 않으면 뇌손상으로 인해 평생 장애를 가지고 살아가야 하는 질환이다. 따라서 뇌졸중 환자가 발생할 경우에는 신속한 진단과 치료가 이루어져야 하므로 장시간의 검사를 해야 하는 MRI 보다는 빠른 검사와 3D 구현이 가능한 뇌 관류전산화단층촬영(Brain Perfusion CT)이 널리 활용되고 있다. 그러나 환자에게 많은 방사선 피폭이 이루어질 수 있기 때문에 저선량(low dose) 기법을 사용하여 영상을 획득하게 된다. 이로 인해 촬영된 영상의 질 저하가 유발되며, 특히 가우시안노이즈의 영향을 크게 받아 정확한 혈관 영상의 확인을 저해한다. 본 연구에서는 관류전산화단층촬영을 통해 얻어진 동적 CT 데이터에 시공간 분석 기법을 적용하여 진단 영상의 질을 향상시키고자 한다. 특히, 가우시안노이즈를 제거하기 위해서 선형 특징 축출 방법 중 하나인 주성분 분석 기법을 적용하여 분석하였으며, 그 결과 시공간 특징에 따른 각각의 관류 영상 성분을 축출한 경우 뇌-혈관 영상뿐만 아니라 뇌-실질 영상의 질이 향상됨을 가시적으로 확인할 수 있었다. 새롭게 시도된 시공간 기반 영상기법이 향후 급성 뇌졸중 진단뿐만 아니라 다양한 시계열 정보가 포함된 뇌질환 진단 영상분석에 활용된다면, 임상 진단의 질 향상에 도움이 될 것이라 기대한다.

동적 전류분담 인덕터를 이용한 ZVT 풀 브리지 컨버터의 병렬 운전 (The Parallel Operation of ZVT-Full Bridge Converter with Dynamic Current Shared Inductor)

  • 김용
    • 조명전기설비학회논문지
    • /
    • 제16권4호
    • /
    • pp.15-21
    • /
    • 2002
  • 본 논문에서는 동적 전류분담 인덕터를 이용한 ZVT 풀 브리지 DC/DC 컨버터의 병렬운전 특성을 해석하였다. 기존의 경우 CT(Current Transformer)를 사용하여 각 단위 컨버터 전류의 크기를 감지하여, 제어회로에서 각 컨버터에 균등한 전류 배분을 하는 방법을 사용하였으나, 본 연구에서는 동적 전류분담 인덕터를 사용함으로써 병렬운전하는 두 대의 풀 브리지 컨버터의 전류분배를 위한 제어회로를 비교적 단순하게 하였다. 동시에 ZVT회로를 이용하여 컨버터의 효율을 향상시켰으며 스위칭소자로서 IGBT를 사용하여 2[㎾]급 시작품을 제작, 50[KHz]에서 실험하였다.

Prevalence of Decreased Myocardial Blood Flow in Symptomatic Patients with Patent Coronary Stents: Insights from Low-Dose Dynamic CT Myocardial Perfusion Imaging

  • Yuehua Li;Mingyuan Yuan;Mengmeng Yu;Zhigang Lu;Chengxing Shen;Yining Wang;Bin Lu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • 제20권4호
    • /
    • pp.621-630
    • /
    • 2019
  • Objective: To study the prevalence and clinical characteristics of decreased myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) in symptomatic patients without in-stent restenosis. Materials and Methods: Thirty-seven (mean age, 71.3 ± 10 years; age range, 48-88 years; 31 males, 6 females) consecutive symptomatic patients with patent coronary stents and without obstructive de novo lesions were prospectively enrolled to undergo dynamic CT-MPI using a third-generation dual-source CT scanner. The shuttle-mode acquisition technique was used to image the complete left ventricle. A bolus of contrast media (50 mL; iopromide, 370 mg iodine/mL) was injected into the antecubital vein at a rate of 6 mL/s, followed by a 40-mL saline flush. The mean MBF value and other quantitative parameters were measured for each segment of both stented-vessel territories and reference territories. The MBFratio was defined as the ratio of the mean MBF value of the whole stent-vessel territory to that of the whole reference territory. An MBFratio of 0.85 was used as the cut-off value to distinguish hypoperfused from non-hypoperfused segments. Results: A total of 629 segments of 37 patients were ultimately included for analysis. The mean effective dose of dynamic CT-MPI was 3.1 ± 1.2 mSv (range, 1.7-6.3 mSv). The mean MBF of stent-vessel territories was decreased in 19 lesions and 81 segments. Compared to stent-vessel territories without hypoperfusion, the mean MBF and myocardial blood volume were markedly lower in hypoperfused stent-vessel territories (77.5 ± 16.6 mL/100 mL/min vs. 140.4 ± 24.1 mL/100 mL/min [p < 0.001] and 6.4 ± 3.7 mL/100 mL vs. 11.5 ± 4 mL/100 mL [p < 0.001, respectively]). Myocardial hypoperfusion in stentvessel territories was present in 48.6% (18/37) of patients. None of clinical parameters differed statistically significantly between hypoperfusion and non-hypoperfusion subgroups. Conclusion: Decreased MBF is commonly present in patients who are symptomatic after percutaneous coronary intervention, despite patent stents and can be detected by dynamic CT-MPI using a low radiation dose.