• 제목/요약/키워드: dual surfaces

검색결과 92건 처리시간 0.033초

습식 DCT(Dual Clutch Transmission) 클러치 팩 내부에서의 체결 동작에 따른 변속기유 거동 연구 (Study on the Lubricant Flow Behaviors in the Wet Clutch Pack System of Dual Clutch Transmission)

  • 김우정;이상호;장시열
    • Tribology and Lubricants
    • /
    • 제33권3호
    • /
    • pp.85-91
    • /
    • 2017
  • This work studies the flow behaviors in the gap between the friction pad and separator in wet-clutch systems. The fluid volume of the lubricant is modeled using the entire system of wet-clutch pack of a dual clutch transmission that has larger outer radius of odd gear shifts and smaller inner radius of even gear shifts. Flow behaviors in the gap of the clutch pad are computed using the gear shift modes that consider the real relative velocities between the friction pad and separator. Flow behaviors in the gap of the disengaged clutch pad are mainly investigated for the wet-clutch system, whereas the engaged clutch pad is modeled with no fluid rate through the contacting surfaces. The developed hydrodynamic fluid pressures and velocity fields in the clutch pad gap are computed to obtain the relevant information for managing flow rates in wet-clutch packs under dual operating conditions during gear shifts. These hydrodynamic pressures and velocity fields are compared on the basis of each gear level and gap location, which is necessary to determine the effects of groove patterns on the friction pad. Shear stresses in the gap locations are also computed on the basis of the gear level for the inner and outer clutch pads. The computed results are compared and used for the design of cooling capacity against frictional heat generation in wet-clutch pack systems.

염산 테트라싸이클린이 이중 산부식 임플란트 표면 구조에 미치는 영향 (The influence of tetracycline-HCI for micromorphology of Thermal dual acid etched surface implants)

  • 정도민;박준봉;권영혁;허익;정종혁
    • Journal of Periodontal and Implant Science
    • /
    • 제37권2호
    • /
    • pp.265-275
    • /
    • 2007
  • The present study was performed to evaluate the effect of Tetracycline-HCI on the change of implant surface microstructure according to application time. Implants with thermal dual acid etched surface were utilized. Implant surface was rubbed with $50mg/m{\ell}$ Tetracycline-HCI solution and sterilized saline for O.5min, 1min, 1.5min, 2min, 2.5min and 3min. respectively in the test group. Then, specimens were processed for scanning electron microscopic observation and measured surface roughness by optical interferometer. The results of this study were as follows. 1. The thermal dual acid etched surfaces showed many small peaks and valleys distributed overall surface. 2. The surface conditioning with Tetracycline-HCI and saline didn't influence on its micromorphology. In conclusion, the implant with thermal dual acid etched surface has a protective micromorphology from the detoxification with $50mg/m{\ell}$ Tetracycline-HCI and a scrubbing with cotton pellet. Therefore, the detoxification with $50mg/m{\ell}$ Tetracycline-HCI is an effective method for peri-implantitis in case implants with thermal dual acid etched surface.

Dynamic Surface In-plane Switching Property using the Ferroelectric Liquid Crystal on the surface

  • Choi, Sang-Ho;Choi, Su-Seok;Shin, Hyun-Ho;Chung, In-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.868-871
    • /
    • 2006
  • In-plane switching characteristics of PI rubbed ITO sandwich cell with low molecule FLC (ferroelectric liquid crystal) surface was investigated. FLC on the surface is governed by the applying frequency and surface condition. By controlling the Ps (spontaneous polarization) direction of dual FLC surfaces, switching characteristics are improved without change of cell structure.

  • PDF

Design of Smart Polymer Constructs for Use in Microfluidic Diagnostic Assays

  • Hoffman Allan S.
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.42-43
    • /
    • 2006
  • We have prepared random, block and graft copolymers with single or dual sensitivities to various stimuli. We have conjugated these polymers to proteins at random lysine sites or at specific sites designed into the protein by genetic engineering. We are also grafting the smart polymers to the surfaces of nanobeads. We are applying these smart conjugates and smart nanobeads in microfluidic devices for various applications, including diagnostics, affinity separations and enzyme bioprocesses. In this talk I will update our work with these interesting hybrid systems.

  • PDF

지연성 운동이상증 환자에서 functionally generated path 술식과 이중스캔법을 이용한 고정성 보철물 제작: 증례 보고 (Fabrication of fixed prosthesis by employing functionally generated path technique and dual scan technique in a tardive dyskinesia patient: a case report)

  • 실파;이두형
    • 대한치과보철학회지
    • /
    • 제61권3호
    • /
    • pp.227-233
    • /
    • 2023
  • 지연성 운동이상증은 도파민 수용체 차단 약물의 장기간 사용으로 인해 발생하는 비자발적 신경학적 운동 장애로 불수의적인 하악의 움직임과 이갈이를 초래하여 과도한 하중이 치아 및 보철물에 위해를 가할 수 있다. 지연성 운동이상증 병력이 있는 40대 남성이 상악 전치부 상실로 인한 보철치료를 위해 내원하였다. #13, 15, 23의 지대치 형성 후 실리콘으로 인상을 채득하고 레진 블록을 밀링하여 임시 보철물을 제작하였다. 시적 과정에서 임시 보철물의 교합면 1/3을 제거하고 교합면에 자가중합 아크릴 레진을 도포하여 환자의 구강에 장착하였다. 레진이 경화되는 동안 하악의 불수의적 움직임으로 대합치에 의한 functionally generated path (FGP)가 레진 표면에서 기록되었다. 수정된 임시 보철물을 제거하여 구내 스캐너로 스캔 후 이중 스캔 방법을 사용하여 임시 보철물의 디자인을 수정하여 최종 보철물을 설계하였다. 최종 보철물은 단일구조 지르코니아로 제작하였다. 본 증례는 FGP 기술과 이중 스캔 방법 이 지연성 운동이상증 환자에서 조화로운 교합을 갖는 고정성 보철물의 제작하는 데 도움이 될 수 있음을 보여준다.

염산테트라싸이클린의 적용시간에 따른 특수 가공된 임프란트 표면 변화 (Micromorphometric change of implant surface conditioned with Tetracycline-HCl : HA and Etched surface)

  • 한주영;박준봉;권영혁;허익;정종혁
    • Journal of Periodontal and Implant Science
    • /
    • 제36권3호
    • /
    • pp.731-744
    • /
    • 2006
  • The present study was performed to evaluate the effect of tetracycline-HCl on the change of implant surface microstructure according to application time. Implant with pure titanium machined surface, HA-coated surface and dual acid etched surface were utilized. Implant surface was rubbed with $50mg/m{\ell}$ tetracycline-HCL solution for ${\frac{1}{2}}$min., 1min., $1{\frac{1}{2}}$min., 2min., and $2{\frac{1}{2}}$min. respectively in the test group. Then, specimens were processed for scanning electron microscopic observation. The results of this study were as follows. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two groups. 2. In HA-coated surfaces, round particles were deposited irregularly. The roughness of surfaces conditioned with tetracycline-HCL was lessened and the cracks were increased relative to the application time. 3. The etched surfaces showed the honey comb structures. The surface conditioning with tetracycline-HCI didn't influence on its micro-morphology. In conclusion, the detoxification with $50mg/m{\ell}$ tetracycline-HCI must be applied respectively with different time according to various implant surfaces.

Etch Characteristics of $SiO_2$ by using Pulse-Time Modulation in the Dual-Frequency Capacitive Coupled Plasma

  • 전민환;강세구;박종윤;염근영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.472-472
    • /
    • 2011
  • The capacitive coupled plasma (CCP) has been extensively used in the semiconductor industry because it has not only good uniformity, but also low electron temperature. But CCP source has some problems, such as difficulty in varying the ion bombardment energy separately, low plasma density, and high processing pressure, etc. In this reason, dual frequency CCP has been investigated with a separate substrate biasing to control the plasma parameters and to obtain high etch rate with high etch selectivity. Especially, in this study, we studied on the etching of $SiO_2$ by using the pulse-time modulation in the dual-frequency CCP source composed of 60 MHz/ 2 MHz rf power. By using the combination of high /low rf powers, the differences in the gas dissociation, plasma density, and etch characteristics were investigated. Also, as the size of the semiconductor device is decreased to nano-scale, the etching of contact hole which has nano-scale higher aspect ratio is required. For the nano-scale contact hole etching by using continuous plasma, several etch problems such as bowing, sidewall taper, twist, mask faceting, erosion, distortions etc. occurs. To resolve these problems, etching in low process pressure, more sidewall passivation by using fluorocarbon-based plasma with high carbon ratio, low temperature processing, charge effect breaking, power modulation are needed. Therefore, in this study, to resolve these problems, we used the pulse-time modulated dual-frequency CCP system. Pulse plasma is generated by periodical turning the RF power On and Off state. We measured the etch rate, etch selectivity and etch profile by using a step profilometer and SEM. Also the X-ray photoelectron spectroscopic analysis on the surfaces etched by different duty ratio conditions correlate with the results above.

  • PDF

Effect of solution temperature on the mechanical properties of dual-cure resin cements

  • Kang, En-Sook;Jeon, Yeong-Chan;Jeong, Chang-Mo;Huh, Jung-Bo;Yun, Mi-Jung;Kwon, Yong-Hoon
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.133-139
    • /
    • 2013
  • PURPOSE. This study was to evaluate the effect of the solution temperature on the mechanical properties of dualcure resin cements. MATERIALS AND METHODS. For the study, five dual-cure resin cements were chosen and light cured. To evaluate the effect of temperature on the specimens, the light-cured specimens were immersed in deionized water at three different temperatures (4, 37 and $60^{\circ}C$) for 7 days. The control specimens were aged in a $37^{\circ}C$ dry and dark chamber for 24 hours. The mechanical properties of the light-cured specimens were evaluated using the Vickers hardness test, three-point bending test, and compression test, respectively. Both flexural and compressive properties were evaluated using a universal testing machine. The data were analyzed using a two way ANOVA with Tukey test to perform multiple comparisons (${\alpha}$=0.05). RESULTS. After immersion, the specimens showed significantly different microhardness, flexural, and compressive properties compared to the control case regardless of solution temperatures. Depending on the resin brand, the microhardness difference between the top and bottom surfaces ranged approximately 3.3-12.2%. Among the specimens, BisCem and Calibra showed the highest and lowest decrease of flexural strength, respectively. Also, Calibra and Multilink Automix showed the highest and lowest decrease of compressive strength, respectively compared to the control case. CONCLUSION. The examined dual-cure resin cements had compatible flexural and compressive properties with most methacrylate-based composite resins and the underlying dentin regardless of solution temperature. However, the effect of the solution temperature on the mechanical properties was not consistent and depended more on the resin brand.

AZ31 마그네슘 합금 판재의 전기저항 이중 스폿용접 특성 (Characteristics of Electric Resistance Dual Spot Welding Process of AZ31 Magnesium Alloy Sheets)

  • 순샤오광;진인태
    • 한국기계가공학회지
    • /
    • 제21권3호
    • /
    • pp.1-11
    • /
    • 2022
  • In this study, an electric resistance dual-spot welding process using a copper electrode inserted in a heating electrode is suggested for the spot welding of AZ31 magnesium sheets. This spot-welding process involves two heating methods for welding at the interfacial zone between the magnesium sheets, one of which is the heating method by thermal conduction from the heating electrode heated by the welding current induced to the steel electrode, and the other heating method uses the electric resistance between the contacted surfaces of the two sheets by the welding current induced to the copper electrode. This welding process includes the welding variables, such as the current induced in the heating electrode and the copper electrode, and the outer diameters of the heating electrode. This is because the heat conducted from the heating electrode can be maintained at a higher temperature in the welding zone, which has a slow cooling effect on the nugget of the melted metal after the welding step. The pressure exerted during the pressing of the magnesium sheets by the heating electrode can be increased around the nugget zone at the spot-welding zone. Thus, it not only reduces the warping effect of the elastoplastic deformation of sheets, but also the corona bond can make it less prone to cracking at the welded zone, thereby reducing the number of nuggets expelled out of the corona bond. In conclusion, it was known that an electric resistance dual spot welding process using the copper electrode inserted in the heating electrode can improve the welding properties in the electric resistance spot welding process of AZ31 magnesium sheets.

양친매성 유기점토를 이용한 중금속과 유기 오염물질 동시제거 기술 (The Application of Dual Function Organoclay on Remediation of Toxic Metals and Organic Compounds in Soil-Water System)

  • 옥용식;임수길;김정규
    • 한국환경농학회지
    • /
    • 제22권3호
    • /
    • pp.177-184
    • /
    • 2003
  • Although clay can sorb significant amounts of inorganic contaminants from soils and wastewater, the hydration of exchangeable cations in clay minerals makes it hydrophilic at the clay mineral surfaces and interlayers. Thus, natural clays are often ineffective in complexing and stabilizing toxic organic contaminants in soils and groundwater environment. But, substituting these hydrated cations with cationic surfactant such as QAC(Quaternary ammonium Compound) can change the natural clay from hydrophilic to hydropobic. Furthermore functionalized organoclay can act as a powerful dual function sorbent for both toxic metals and organic compounds. It also can be used as landfill clay liners, slurry walls, nano-composite materials, petroleum tank farms, waste treatment, and filter systems. To use this modified clay minerals effectively, it is required to understand the fundamental chemistry of organoclay, synthetic procedures, its engineering application, bioavailability of sorbed ion-clay complex, and potential risk of organoclay. In this review, we investigate the use, application and historical background of the organoclay in remediation technology. The state-of-the-art of organoclay research is also discussed. Finally, we suggest some future implications of organoclay in environmental research.