• Title/Summary/Keyword: dry test

Search Result 1,856, Processing Time 0.038 seconds

Decontamination of Simulated Test Piece by Dry Ice Pellet Blasting (드라이아이스 펠렛 분사에 의한 모의 시편의 제염)

  • Shin Jin-Myeong;Park Jang-Jin;Yang Myung-Seung
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.2
    • /
    • pp.30-36
    • /
    • 2004
  • Dry decontamination technique is required for maintaining nuclear material handling equipment contaminated with highly radioactive material in a hot cell. In order to determine the optimum blasting conditions of dry ice pellet blasting device, the basic experiments have been conducted on the simulated test specimens of four types of metals. The removal efficiency of test piece was evaluated by the XRF analysis and the change of the surface condition before and after blasting. The removal efficiency of cesium on loose contamination was 100% under blasting pressure; 3 kg/$cm^2$, blasting distance; 10 cm, blasting time: 10 sec. In case of fixed contamination, the removal efficiency of cesium was almost 96% under blasting pressure; 4kg/$cm^2$, blasting distance; 10 cm, blasting time; 30 sec.

A Study on Design of Dry Floor Tile Unit Method System (바닥타일 건식공법용 수지매트 개발에 관한 연구)

  • 김상미;조상영;김성식;임남기;정병훈;김무성
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.22-27
    • /
    • 2001
  • The purpose of this study is development of dry floor tile method that practically used for improving wet method's defect, with resin mat design. PE resin used mat which satisfied with bonding test, waterproof test, resistance to chemical attack test, resistance to impact test and freezing and thawing test is confirmed the basic property.

  • PDF

The Study of Performance Evaluation Coefficient of Fin-and-Tube Heat Exchangers with Frosting (착상을 수반한 핀-관 열교환기의 성능평가계수에 관한 연구)

  • 최봉준;황준현;신종민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.132-136
    • /
    • 2003
  • For the study of performance evaluation on different shape heat exchangers that have the same energy consumption in a refrigerator, we make performance evaluation coefficient (PEC) which can distinguish performance of different shape heat exchangers. The results were reported in order to compare with for the dry frosting and wet frosting test as various definition of PECs. Results showed that PEC of dry frosting test is higher than that of wet frosting test because attached water droplet increases pressure drop of air-side then this decreases performance of heat exchanger.

EFFECT OF A REWETTING AGENT ON DENTIN ADHESION (재습윤제의 적용이 상아질 접착에 미치는 효과)

  • Cho, Young-Gon;Park, Yil-Yoon;Lee, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.11-22
    • /
    • 2003
  • This study compared the dentin adhesion to composite resin according to air-dry, blot dry, application of rewetting agent on air-dry or blot dry dentin surface by microleakag test and SEM observation. For microleakage test, class V cavity preparations with dentinal margins were prepared on both buccal and lingual surfaces of 40 extracted human molars. For SEM observation, occlusal dentin of 20 extracted human molars were exposed. After etched the dentin, prepared teeth were randomly divided into four groups; D group: air dry for 10-15 sec., B group: blot dry with moist cotton pellet, D-R group: air dry and rewet with Aqua-Prep F for 20 sec., B-R group: blot dry and rewet with Aqua-Prep F for 20 sec. Treated cavities and surfaces were filled or constructed using One-Step adhesives and Aelitefil composite resins. Specimens were stored in distilled water for 24 hours. For microleakage test, the specimens were thermocycled and soaked into 2% methylene blue. The specimens were sectioned longitudinally and evaluated for microleakage under steromicroscope. The data were statistically analysed by Kuskal-Wallis Test, Mann-Whitney and Wilcoxon signed ranked tests. For SEM observation, the specimens were bisectioned mesiodiatally. After decalcified and deproteinized, specimens were observed under SEM. The results of this study were as follows; 1. The microleakges on dentinal margin were the highest in D group compared with B group, D-R group, and B-R group(p<0.05). But there was no significant difference between B group, D-R group and B-R group. 2. D group showed gap and a few resin tags between dentin and composite resin. 3 B group, D-R group, and B-R groups showed close adaptation between dentin and composite resin. It showed that resin rags in B group were numerous and long, in D-R group were few and short, in B-R group were numerous and short or long. 4. Adhesive layer showed in D-R group ($10{\;}\mu\textrm{m}$) and B-R group ($3{\;}\mu\textrm{m}$) In conclusion, use of rewetting agent to dry dentin was efficient to dentin adhesion, also it did not provide reverse effect on blot dry dentin.

Comparative Analysis of Questionnaires for Dry Eye Screening Test (안구건조증 설문지의 일치도 연구)

  • Kim, Da-Young;Lee, Sun-Haeng;Cho, Hyun-Gug;Kim, Kun-Kyu;Kim, Ha-Na;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.499-504
    • /
    • 2014
  • Purpose: This study is to evaluate the accuracy of dry eye screening test by comparing coincidences between three types of questionnaires and objective tests. Methods: 90 adults were classified into the normal and dry eye groups using evaluations of three types of questionnaires (SPEED, OSDI, TERTC-DEQ) and objective tests (NIBUT, Schirmer test). Coincidences-between the results of objective tests and questionnaires were compared and analyzed for dry eye diagnosis. Results: Coincidences between NIBUT test and each questionnaire were 83.3% by SPEED, 77.8% by OSDI and 72.3% by TERTC-DEQ, respectively. Concordance by SPEED was highest among three types of questionnaire. Coincidences between the Schirmer test and each questionnaire were 57.8% by SPEED, 58.9% by OSDI and 73.3% by TERTC-DEQ, respectively, thus coincidence by TERTC was higher than by others. But coincidences by Schirmer test were generally lower than those by NIBUT test. Conclusions: SPEED questionnaire showed the highest concordance with objective test as compared with others. Therefore, SPEED is expected to be used usefully to diagnose dry eyes.

A study of acoustic and vibration character of High volume dry vacuum pumps (대용량 건식 진공펌프의 음향.진동 특성 연구)

  • Shin, Yun-Sang;Cheung, Wan-Sup;Hong, Dong-Pyo;Lim, Jong-Yeon;Kim, Se-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1313-1316
    • /
    • 2006
  • Demands of high volume dry vacuum pumps on the domestic semiconductor and LCD industries are rapidly increasing as the size of wafers and LCD is increasing. This study introduces a new experimental setup for testing the reliability of vacuum pumps. The test system was designed to measure the acoustic pressure and mechanical vibration levels simultaneously. It is shown that the test system enables the analysis and evaluation of the performance of dry pumps under the different gas-load conditions. Detailed experimental result are shown to enable us to examine the characteristics and performance of dry pumps.

  • PDF

A Study on Stress-Strain Characteristics of Compacted Bentonite for High-Level Radioactive Waste Repository (고준위폐기물 차폐용 압축벤토나이트의 응력-변형률 거동 분석)

  • Kim, Do-Hyun;Jeong, Sang-Seom
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.792-797
    • /
    • 2009
  • The stress-strain characteristics of compacted bentonite are investigated using experimental triaxial compression test by Hoek-cell. Special attention given to various dry density and water absorption ratio. Based on the test results, it is shown that the stress-strain relationship of compacted bentonite is highly influenced by dry density and water absorption ratio. Also, characteristics of Bentonite is similar to the clay rather than sand. Strength of compressed Bentonite increases with higher dry density. It shows maximum strength value, if in a same condition with dry density and constrain pressure. So we determine that value as the optimistic moisture contents for the maximun strength of compressed Bentonite.

  • PDF

VOC Emission Characteristics of Dry Cleaned Wool Scarfs through Small Chamber Test (소형챔버를 이용한 드라이클리닝 모직물 목도리의 휘발성유기화합물 방출 특성)

  • Shin, Jin-ho;Kwon, Seung-mi;Kim, Hyun-soo;Roh, Bang-Sik;Kim, Kwang-rae;Eo, Soo-mi;Jung, Kweon;Lee, Young-Kyu
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.2
    • /
    • pp.95-102
    • /
    • 2017
  • Objectives: This study was conducted to evaluate the emission of VOCs from clothing that had been dry cleaned. Methods: In order to ensure the same conditions, f100% wool scarves were selected as the fabric type. Four identical tests were conducted on the option of either removing the plastic bags which came from the dry cleaning shop or not. The scarf was located inside a closet or room for one or two days. Small chamber tests were conducted to determine the VOC emission characteristics under the same conditions such as temperature, humidity, loading factor, and air exchange rates. Air from the chamber for VOCs was sampled by Tenax TA tube and analyzed by thermal desorption and GC/MSD. Results: Assuming that test represented dry cleaning and consumer's conditions well enough, we can conclude that immediate emissions after the dry cleaning of the scarfs caused elevated levels of TVOC, five VOCs (benzene, toluene, ethylbenzene, xylene, stylene), and decane group compounds. Conclusions: By removing the plastic bags which came from the dry cleaning shop or not, the storage conditions of dry cleaned scarfs by consumers during the storage time periods (one to three days) would be significant for reducing VOC emissions.

Evaluation on Early-Age Strength of Very-Early-Strength Dry-Mix Shotcrete (초속경 건식 숏크리트의 조기강도 평가)

  • Choi, Sung-Yong;Seo, Jae-Yeop;Jung, Beom-Seok;Yun, Kyong-Ku;Kim, Ki-Heon;Kim, Yong-Gon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.519-520
    • /
    • 2009
  • The purpose of this research was to develop a very-early-strength dry-mix shotcrete without accelerator using a rapid-setting cement, to analyze the correlationship of test results among cube test, core test, pullout test and maturity

  • PDF

Effects of dry eye syndrome symptoms and asthenopia on vision-related quality of life in middle-aged patients with dry eye syndrome (중년기 안구건조증 환자의 안구건조 증상정도와 안구피로가 시력관련 삶의 질에 미치는 영향)

  • Yoon, Hye Sook;Kim, Hyun Kyoung
    • Journal of Home Health Care Nursing
    • /
    • v.29 no.3
    • /
    • pp.310-318
    • /
    • 2022
  • Purpose: This is a cross-sectional study aimed to investigate the effects of dry eye syndrome symptoms and eye fatigue on the vision-related quality of life (QOL) of middle-aged patients with dry eye syndrome. Methods: The participants of this study were 94 ophthalmology clinic outpatients aged 40-59 years who were diagnosed with dry eye syndrome at A and S Ophthalmology Clinics in D City, South Korea, and were exhibiting dry eye syndrome symptoms. Data were collected from July 5, 2021 to July 22, 2021, and analyzed using independent t-test, analysis of variance, Scheffe test, Pearson's correlation coefficient, and multiple regression analysis using the SPSS/WIN 25.0 program. Results: The severity of dry eye syndrome symptoms and asthenopia (r=.73, p<.001) in the participants were positively correlated, whereas the severity of dry eye syndrome symptoms and vision-related quality of life (r=-.76, p<.001) were negatively correlated. Additionally, there was a negative relationship between eye fatigue and vision-related QOL (r=-.55, p<.001). It was found that the final factors affecting the vision-related QOL of middle-aged patients with dry eye syndrome were the severity of dry eye syndrome symptoms (β=-0.76, p<.001) and dry eye stress (β=-0.14, p=.048). The explanatory power of vision-related QOL in the participants was 56.0%. Conclusion: To develop indices that can objectively measure patients' subjective symptoms for improving their vision-related QOL is necessary.