• Title/Summary/Keyword: drop test

Search Result 1,300, Processing Time 0.026 seconds

Nose Landing Gear Drop-test Simulation using Numerical Analysis about Orifice (오리피스 유량해석을 통한 전륜 착륙장치의 착륙성능평가)

  • Hwang, Jaeup;Bae, Jaesung;Hwang, Jaihyuk;Hong, Yehsun;Park, Sangjoon;Chung, Taekyong
    • Journal of Aerospace System Engineering
    • /
    • v.8 no.1
    • /
    • pp.18-23
    • /
    • 2014
  • This thesis is simulated a aircraft nose landing gear drop-test. flow rate-to-pressure difference characteristics of damping orifices for a nose landing gear is investigated by CFD analyses. Orifice is kind of poppet valve type. it is simulated pressure drop with variable orifice area. it is simulated landing gear model by using ADAMS with CFD result. It's performance evaluated landing gear drop-test and analyzed the results.

Numerical simulation of complex hexagonal structures to predict drop behavior under submerged and fluid flow conditions

  • Yoon, K.H.;Lee, H.S.;Oh, S.H.;Choi, C.R.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.31-44
    • /
    • 2019
  • This study simulated a control rod assembly (CRA), which is a part of reactor shutdown systems, in immersed and fluid flow conditions. The CRA was inserted into the reactor core within a predetermined time limit under normal and abnormal operating conditions, and the CRA (which consists of complex geometric shapes) drop behavior is numerically modeled for simulation. A full-scale prototype CRA drop test is established under room temperature and water-fluid conditions for verification and validation. This paper describes the details of the numerical modeling and analysis results of the several conditions. Results from the developed numerical simulation code are compared with the test results to verify the numerical model and developed computer code. The developed code is in very good agreement with the test results and this numerical analysis model and method may replace the experimental and CFD method to predict the drop behavior of CRA.

Immediate Effects of Ankle Dorsiflexor Facilitation Dynamic Taping on Static and Dynamic Balance and Gait Speed in Stroke Patients With Foot Drop (발등굽힘근 촉진 다이나믹 테이핑이 발 처짐이 있는 뇌졸중 환자의 정적, 동적 균형과 보행 속도에 미치는 즉각적 효과)

  • Im, Jin-gu;Kim, Suhn-yeop
    • Physical Therapy Korea
    • /
    • v.29 no.1
    • /
    • pp.19-27
    • /
    • 2022
  • Background: Foot drop is a common symptom in stroke patients. Tape applications are widely used to manage foot drop symptoms. Previous studies have evaluated the effects of static and dynamic balance and gait on foot drop using kinesiology tape; however, only few studies have used dynamic tape application in stroke patients with foot drop. Objects: The purpose of this study was to investigate the immediate effects of dynamic taping, which facilitates the dorsiflexor muscle, on static and dynamic balance and gait speed in stroke patients with foot drop. Methods: The study included 34 voluntary patients (17 men, 17 women) with stroke. The patients were randomly assigned to the experimental group (n = 17), wherein dynamic taping was used to facilitate the dorsiflexor muscle, or the control group (n = 17), wherein kinesiology taping was used. Before the taping application, velocity average, path-length average, Berg balance scale, and timed up and go test (TUG) were recorded to measure static and dynamic balance, whereas the 10-meter walk test (10MWT) was used to measure gait speed. After the taping application, these parameters were re-evaluated in both groups. Repeated measure analysis of variance was used. Statistical significance levels were set to α = 0.05. Results: Except for the 10MWT scores in the control group, significant differences were noted in all the parameters measured for static and dynamic balance and gait speed between the pre and post-test (p < 0.05). However, the parameters showed significant interaction effects between group and time in the TUG and 10MWT (p < 0.01). Conclusion: These results indicate that compared with kinesiology taping, dynamic taping used in chronic stroke patients with foot drop had a more significant effect on dynamic balance and gait speed.

Pressure Drop and Leakage Performances of Flat Seals with Inclined Grooves (경사 그루브를 갖는 평판 실의 압력 강하 및 누설 성능)

  • Jung, Jin Woo;Jeong, Gwon Jong;Hwang, Sung Ho;Kim, Tae Ho;Kim, Eojin
    • Tribology and Lubricants
    • /
    • v.38 no.5
    • /
    • pp.213-221
    • /
    • 2022
  • This paper presents performance measurements of pressure drop and leakage flow rate of test flat seals with asymmetric inclined grooves. This study aims to reveal the influence of groove shapes, often machined in radial film riding-face seals, in forming a hydrodynamic wedge on leakage performance. A test facility was developed, and test seals were manufactured to study the effects of the inlet pressure level, ratio of inlet to outlet pressure, seal groove length, and seal groove height on the steady-state pressure drop and leakage performance. A series of tests were conducted, and the test data were compared to the predictions from a simple and efficient mathematical model using a one-dimensional Reynolds equation. The test results revealed that an increase in the inlet pressure increased the pressure drop through the test seals. The leakage flow rate increased significantly as the inlet pressure and ratio of the inlet to outlet pressure increased. The groove shape also affects seal performance. An increase in the groove length and height resulted in an evident increase in the leakage flow rate. The simple model predictions underestimated the leakage flow rates but showed good agreement with the trend in the measurements for all test operating conditions and changes in the groove shape.

Effects of Navicular Drop on Lumbar Disc Herniation (주상골 하강이 요추 추간판 탈출증에 미치는 영향)

  • Hwang, Gwon-Pil;Jung, Min-Keun;Park, Hyun-Sik
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.19 no.2
    • /
    • pp.19-22
    • /
    • 2013
  • Background: Excessive pronation of the feet can cause excessive inner rotation of the femur, followed by increased stress in the gluteus maximum, increased front slope of the pelvis, and lumbar lordosis, which leads to lumbar pain. The aim of the present study was to use the navicular drop test to examine foot pronation that can cause lumbar lordosis and to determine whether the navicular drop is lower in patients diagnosed with lumbar disc than in patients without this diagnosis. Methods: The Navicular Drop score was set by subtracting the navicular height at a standing position from the navicular height in a sitting position. The Navicular Drop measurements for college student with and without Lumbar Herniated Intervertebral Disc were compared using an independent t-test. Results: The control group were measured right $7.44{\pm}2.96$ and left $8.04{\pm}3.23$. The experimental group were measured right $2.12{\pm}1.33$ and left $2.80{\pm}1.29$. Therefore significant difference was found between the two groups (p<0.05). Conclusions: The navicular drop affected lumbar herniated intervertebral disc.

  • PDF

Board-Level Drop Analyses having the Flip Chips with Solder balls of Sn-3.0Ag-0.5Cu and Sn-1.0Ag-0.5Cu (Sn-3.0Ag-0.5Cu 및 Sn-1.0Ag-0.5Cu 조성의 솔더 볼을 갖는 플립칩에서의 보드레벨 낙하 해석)

  • Kim, Seong-Keol
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.2
    • /
    • pp.193-201
    • /
    • 2011
  • Recently, mechanical reliabilities including a drop test have been a hot issue. In this paper, solder balls with new components which are Sn-3.0Ag-0.5Cu and Sn-1.0Ag-0.5Cu-0.05N are introduced, and board level drop test for them are conducted under JEDEC standard in which the board with 15 flip chips is dropped as 1,500g acceleration during 0.5ms. The drop simulations are studied by using a implicit method in the ANSYS LS-DYNA, and modal analysis is made. Through both analyses, the solder balls with new components are evaluated under the drop. It is found that the maximum stress of each chip is occurred between the solder ball and the PCB, and the highest value among the maximum stresses in the chips is occurred on the chip nearest to fixed holes on the board in the drop tests and simulations.

Weight Drop Impact Tests of Earthquake-Proof Table (내진테이블의 중량물 낙하 충격실험)

  • Eom, Tae Sung;Huh, Seok Jae;Park, Tae Won;Lee, Sang Hyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.7
    • /
    • pp.369-378
    • /
    • 2018
  • Full-scale seismic retrofit of old and deteriorated masonry buildings requires a lot of cost and time. In such buildings, installing an emergency evacuation space can be considered as an alternative. In this study, requirements of the earthquake-proof table used as an emergency evacuation space for buildings hit by earthquake are investigated. Load conditions required for the table, including the impact effects due to building debris drop, are explained. To investigate the impact effects in more detail, weight drop test is performed for an prototype earthquake-proof table. In the test, the weight of the falling object and free fall height were considered as the main test parameters. The results showed that the duration of impact is very short (0.0226~0.0779sec), and thus the impact forces increase to 15.8~45.2 times the weight of the falling object. Based on these results, design considerations and performance verification criteria of the earthquake-proof table as an emergency evacuation space are given.

Acceleration Test of Ion Migration for PCB Electronic Reliability Evaluation (PCB 전기적 신뢰성평가를 위한 이온 마이그레이션 가속시험)

  • Lee, D.B.;Kim, J.H.;Kang, S.K.;Chang, S.W.;Lim, J.H.;Ryu, D.S.
    • Journal of Power System Engineering
    • /
    • v.9 no.1
    • /
    • pp.64-69
    • /
    • 2005
  • In evaluation of electronic reliability on the PCB(Print Circuit Borad),electrochemical migration is one of main test objects. The phenomenon of electrochemical migration occurs in the environment of the hight humidity and the hight temperature under bias through a continuous aqueous electrolyte. In this paper, the generating mechanism of electrochemical migration is investigated by using water drop acceleration test under various waters. The waters used in the water drop test are city water, distilled water and ionic water. It found that the generated velocity of electrochemical migration depended on electrolyte quantity which included in the various waters.

  • PDF

A study on the strengthening of Sodalime glass using ion exchange method (이온강화법을 이용한 소다라임 글라스 강화에 관한 연구)

  • Ahn, H.W.;Oh, J.H.;Kweon, S.G.;Choi, S.D.
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.6
    • /
    • pp.145-151
    • /
    • 2014
  • The glass used for mobile display windows is required to have high strength. Chemical strengthening by means of ion exchange is widely used glass. The depth of the layer and the compressed stress are affected by tempering temperature and time. The purpose of this study is to investigate the range of DOL and CS, which to less breakage during reliability tests such as the ball drop test, hole drop test, 3-point bending test, drop test, and tumble test with Soda-lime Glass.

An Experimental Study on Ducted Silencers I (ISO 7235) (덕트 소음기의 실험적 연구 I (ISO 7235))

  • 남경훈;박희주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.282-287
    • /
    • 2001
  • The test facility has been manufactured to predict the dynamic insertion loss and the pressure drop for ducted silencers based on ISO 7235. The qualification test of the test facility is necessary for determining the dynamic insertion loss and the pressure drop of the test silencer, and is surveyed the reflection coefficient for an anechoic termination, the velocity profile near the upstream connection to the test silencer, the reduction of the system silencer and the limiting insertion loss due to the flanking sound transmission along the duct walls.

  • PDF