• Title/Summary/Keyword: drop size

Search Result 798, Processing Time 0.028 seconds

Evaluation of Changesin the Physical Characteristics of Raindrops Under a Canopy in Central Korea (나무 아래 빗방울(雨滴)의 물리적 특성변화 분석)

  • Kim, Jin Kwan;Kim, Min Seok;Yang, Dong Yoon;Lim, Young Shin
    • Journal of The Geomorphological Association of Korea
    • /
    • v.23 no.3
    • /
    • pp.105-122
    • /
    • 2016
  • To evaluate the changes in the physical characteristics of open rainfall related to canopy effects and rainfall intensity in Korea, the terminal velocity of raindrops and drop size distributions(DSD) were continuously measured by an optical-laser disdrometer in an open site(Op) and in two forest stands(Th1: Larix leptolepis, Th2: Pinus koraiensis) during five rainfall events in 2008. The terminal velocity, DSD and two forms of kinetic energy(KE, $Jm^{-2}$ $mm^{-1}$; KER, $Jm^{-2}$ $h^{-1}$) of open rainfall drops were determined and were compared with those of throughfall drops under two different canopy heights. The effects of the canopy and rainfall intensity, together with wind speed, on the changes in drop size and kinetic energy of throughfall were evaluated. Throughfall drops were larger than open rainfall drops. The distribution of terminal velocities for the drop sizes measured at Th2 was lower than that at Op; however, at Th1 the distribution was similar to that at Op. The total kinetic energy of throughfall at Th1 and Th2 was higher than the total kinetic energy of open rainfall, and the kinetic energy distribution for the drop sizes wassimilar to the drop size distribution. The observed throughfall-KER at Th1 was lower than an estimate previously produced using a model. The overestimation from the modeled value at Th1 was likely to be due to overestimated values of a square root transformation of fall height and its coefficient in the model because the distributions of terminal velocity for the drop size measured at Th1 were similar to those of open rainfall.

Pressure drop in packed beds with horizontally or vertically stratified structure

  • Li, Liangxing;Xie, Wei;Zhang, Zhengzheng;Zhang, Shuanglei
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2491-2498
    • /
    • 2020
  • The paper concentrates on an experimental study of the pressure drop in double-layered packed beds formed by glass spheres, having the configuration of horizontal and vertical stratification. Both single-phase and two-phase flow tests are performed. The pressure drop during the test is recorded and the measured data are compared with those of homogeneous beds consisting of mono-size particles. The results show that for the horizontally stratified bed with fine particles atop coarse particles, the pressure drop in top layer is found higher than those of homogenous bed consisting of the same smaller size particles, while the measured pressure drop of bottom part is similar with those of similar homogenous bed. But for the homologous bed with upside-down structure, the stratification has little or no effect on the pressure drop of the horizontally stratified bed, and the pressure drop of each layer is almost same as that of homogeneous bed packed with corresponding spheres. Additionally, in vertically stratified bed, the pressure drops on the left and right side is almost equal and between those in homogeneous beds. It is speculated that vertically stratified structure may lead to lateral flow which redistributes the flow rate in different parts of packed bed.

The Study of Somatotype According to the Drop of Women in Their 20's (20대 여성의 드롭에 따른 체형 연구)

  • Park, Ju-Hee;Hong, Jung-Min;Yoon, Jin-Kyung
    • Fashion & Textile Research Journal
    • /
    • v.7 no.5
    • /
    • pp.494-500
    • /
    • 2005
  • This study classifies somatotype from exact measurements according to the women somatotype with different drop value and isfunctional and has high body fitness. This study was preceded in the following process. Took 147 women in their 20's measurement directly and grasped the general body characteristic, and classified somatotype according to distribution of drop. Drop value is classified into Drop I, Drop II, and Drop III. Drop I is the difference value between bust line and waist line measurement. Drop II is the difference value between hip line and waist line measurement. Drop III is the difference value between hip line and bust line measurement. Suggested distribution of somatotype based on drop istribution. Classified somatotype into 4 types according to the mixture of combination of Drop I, II, and III. Comprehended the characteristics of somatotype based on basic statistical data. Type 1, M type, displays 40 % distribution that is most high distribution rate among four types and it is normal type which is similar to average value in size in the this study. Type 2, A type, displays 32.4% and it's a lower half of their body developed type with a flat busted and hippy. Type 3, X type, displays 19% and it's a healthy type with tall height, slender waist and curves of bust and hip lines. Type 4, H type, displays 8.6% and it's a biggest type in size which is busty, full hipped and nearly has no curves of body line.

A study on the Characteristics of the Blowing type Rotary Burner (송풍형 로터리 버너의 특성 연구)

  • Choi Y. H.;Kim K. H.;Yoon S. J.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.303-306
    • /
    • 2002
  • Liquid atomization by means of a spinning cup is widely used as a device for combustion, in cooling and spray drying. In this study, the blowing type rotary atomizer was experimental carried out the investigations on the characteristics of the blowing type rotary atomizer which is an air flow energy of blower instead of an electric motor most commonly used to a driven energy. The analysis on the rotary cup speed, air velocity with the blower conditions was performed and also the drop size was measured using LDPA. It was tried to analyzed on air-nozzle size and liquid flowrate as the result. It was found that the increase of the relative velocity between liquid and air improve significantly atomization liquid, and decrease of the liquid flowrate improved the maximum drop size though the mean drop size is really the same.

  • PDF

An Analysis of The Preferred Ease of Torso Sloper by Body Size (신체크기에 따른 토르소원형의 부위별 선호여유량 분석)

  • Kang, Yeo-Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.1
    • /
    • pp.112-125
    • /
    • 2012
  • This study researches the preferred ease of torso sloper according to body sizes and drop. For this, the eases of main body parts such as chest circumference, waist circumference, hip circumference, biacromion length, and waist back length were analysed; in addition, the drop differences of body and pattern were explored to find out characteristics of silhouette changes. The subjects were 55 women in their early 20s (aged from 20 to 24) and individual torso block made with muslin was corrected 1-3 times by a personal fitting. There were 3 meaningful results. First, the preferred ease were individually various; however, the eases of all torso blocks should be same at the pattern making step. Second, the eases were also significantly different among body size groups and the bigger group preferred less ease at the biacromion length, waist back length, armhole-depth, chest circumference, and waist circumference. Third, the eases of chest circumference and hip circumference were significantly changed among drop groups. To change their body drop, H-shape drop adopted less ease at chest circumference and more ease at hip circumference; however, A-shape drop adopted more ease at chest circumference and less ease at hip circumference.

An Experimental Study on the Behavior of Twin-Spray with Flow Interaction in a Condensable Environment (주위기체내에서의 두 액체분무간의 유동간섭현상에 대한 정상적 고찰)

  • 이상룡;정태식;한기수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.3
    • /
    • pp.326-334
    • /
    • 1986
  • The effects of flow interaction between adjacent sprays in twin-spray system on the spatial distribution of injected liquid (water) and drop size distribution in condensable (steam) environment were carefully observed through experiments. The spatial distribution of injected liquid in twin-spray system appears to be more uniform than the simple superposition of the spatial distributions of liquid obtained from each individual spray. Drop size distribution was obtained by using the immersion sampling technique. It was found that, in the twin-spray, the larger numbers of small drops are collected throughout the spraying region due to the increase of entrainment velocity of ambient steam compared with the case of simple superposition of each individual spray. Moreover, in the overlapped portion of the twin-spray, the drop size distribution was changed also due to the collision between large drops. As a result, the behavior of twin-spray system (and eventually multiple-spray system) can not be predicted precisely by simple superposition of the behaviors of each constituting spray. Hence, for the design of multiple spray system, the effect of flow interaction between sprays should be taken into account seriously.

Analysis of Voltage Drop and Thermal Characteristics for Poor Connections at Electrical Connector of Circuit Breaker of Small Size Pulverizer below 5.5kW (5.5kW이하의 소형분쇄기 차단기 접속부의 접촉불량에 의한 전압강하 및 열적 특성 분석)

  • Kim, Sang Chul
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.26-31
    • /
    • 2015
  • This paper describes the characteristics of voltage drop and thermal for poor connection on electrical connector of circuit breaker in control box of small size pulverizer. In order monitor, we did the changes of RMS in voltage and temperature value with video and made normal state over $2.5N{\cdot}m$ and poor connections state below $0.2N{\cdot}m$ by screw gage. In case of voltage signal, the voltage drop was increased when the current was increased due to poor connections. In case of temperature signal, the temperature difference indicates ten times at 5A and fourteen times at 15A in the normal state. According to increase thermal energy, the insulation of electrical wiring and connector of circuit breaker can be carbonized. The results of this study will be useful to the development of preventive devices and system for electric fire by poor connection at small size pulverizer.

Characteristics of the Ceramic Filter with the Control of Particle Size and Graphite Additive for the Hazardous Particle and Gas Removal (입도와 흑연 첨가제에 따른 유해 입자 및 가스 동시제거용 세라믹필터 특성평가)

  • Cho, Eul-Hun;Lee, Kun-Jae
    • Journal of Powder Materials
    • /
    • v.21 no.6
    • /
    • pp.454-459
    • /
    • 2014
  • In this study, the porous ceramic filter was developed to be able to remove both dust and hazardous gas contained in fuel gas at high temperature. The porous ceramic filters were fabricated and used as a catalyst support. And the effects have been investigated such as the mean particle size, organic content and addition of foaming agent on the porosity, compressive strength and pressure drop of ceramic filters. With the increase of mean powder size and the organic content for the cordierite filter, the porosity was increased, but the compressive strength and pressure drop were decreased. From the results of the research, the optimum condition for the fabrication of ceramic filters could be acquired and they had the porosity of 58%, the compressive strength of 13.4 MPa and the pressure drop of 250 Pa. It was expected that this ceramic filter was able to be applied to the glass melting furnace, combustor, and dust/toxic gas removal filter.

Greenhouse Cooling by Fog System (FOG SYSTEM 을 이용한 여름철 온실냉방)

  • 서원명
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.1
    • /
    • pp.60-71
    • /
    • 1999
  • This study was performed to improve underirable warm greenhouse environment by fog cooling system in summer season. The resultsof droplet size analysis and cooling effects for fog cooling system are summarized as follows ; 1. At the pump pressure of 70kgf/$\textrm{cm}^2$ , the mean (SMD) drop size was 22.6${\mu}{\textrm}{m}$ and the maximum and minimum drop size was 45.68${\mu}{\textrm}{m}$ and 1.73${\mu}{\textrm}{m}$ , respectively, and almost all of the drop size was less than 40${\mu}{\textrm}{m}$. 2. The temperature of fog cooling greenhouse with 60% shading was dropped more than 2$^{\circ}C$ below the ambient temperature , while the greenhouse temperature without shading was 1$^{\circ}C$ higher than the ambient temperature. 3. It was found that fog spraying intervals were significantly influential on cooling effect. 4. When the greenhouse was ventilated sufficiently by natural vent system, green house temperature could be maintained by 2.5$^{\circ}C$ lower than the ambient temperature, while it was difficult to drop the greenhouse temperature below ambient temeperature without sufficient ventilation. 5. It was found that the temperature of experimental greenhouse could be maintained 3$^{\circ}C$ to 14$^{\circ}C$ lower that of control greenhouse though there were variations depending on experimental and weather conditions.

  • PDF

A study on spray characteristics of the triplet impinging stream type injector for liquid rocket (액체 로켓용 충돌형 Triplet 인젝터의 미립화 특성에 관한 연구)

  • Park, Sung-Young;Kim, Seon-Jin;Park, Seung-Woon;Kim, Yoo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.3
    • /
    • pp.1005-1014
    • /
    • 1996
  • An experimental investigation has been carried out to examine the influence of injector design variables and operating conditions on the resultant drop size for triplet impinging streams injectors. The variables studied in this investigation are pressure drop, impinging angle, orifice length to diameter ratio, and impinging point distance. Droplet-size data are obtained using water as the propellant simulant by Malvern Particle Analyzer System. Drop size decreases with increasing impinging angle and pressure drop while other injector parameters remain constant at the same point. But it is found that there is no noticeable droplet-size change which results from change in orifice length to diameter ratio or impinging point distance within the investigated range.