• 제목/요약/키워드: double windows

검색결과 89건 처리시간 0.022초

한식 창호의 개구 면적에 따른 기밀 및 차음 성능간 상관성 연구 (A Correlation Analysis between the Airtightness and Sound Insulation Performance on the Opening Spaces of Han-style Windows)

  • 이주엽;장현충;이태강;송민정;김선우
    • KIEAE Journal
    • /
    • 제14권3호
    • /
    • pp.87-95
    • /
    • 2014
  • The purpose of this study is to evaluate the correlation coefficients between the airtightness and sound insulation performance of Han-style windows in New Han-ok. To achieve these goals, field measurements were accomplished in 18 bedrooms of 16 Han-oks in which actual residents were living, and then lab measurements were proceeded in the reverberation lab for evaluating the sound insulation performance. Followings are results. The results of the correlation analysis between the airtightness(Air change per hour at 50 Pa, ACH50) and sound insulation performance(Sound reduction index, Rw) in bedrooms of actual Han-oks, it was found that there were no significant correlation between two evaluating values. On the other hand, it was analyzed that the correlation coefficients of total 24 structures(double casement windows, single casement window, casement and sliding windows, single sliding window, 6 types per each structure) were located on 0.6757 exponentially and 0.4154 lineary in the lab evaluating conditions. But, The results of evaluating 4 structure classificatorily, it was found that there were high correlation coefficients(0.8665~0.9273 at ACH50, 0.8414~0.9346 at Rw). These results were signified that the correlation coefficients were changed according to the each structure and case by case analysis were necessary at the same time.

Airborne Sound Insulation Performance of Window and Indoor Noise Level in the Balcony Expanded Apartments

  • Park, Hyeon Ku
    • KIEAE Journal
    • /
    • 제15권2호
    • /
    • pp.61-67
    • /
    • 2015
  • Purpose: The balcony in the apartment is important space not only as a fire escape but also as a buffer for heat and sound insulation. However, with the legalization of balcony expansion for residential apartments in Korea in 2006, many households have eliminated the balcony space altogether to increase the inner space, often without sufficient consideration for the effects on the indoor environment. This study examined the sound insulation performance of exterior-facing windows in enclosed balconies and the changes in the indoor acoustic environment due to expansion to provide a basis for appropriate balcony expansion. The apartments for the field test were chosen where two balcony types can be compared, and the sound insulation performance for the eighteen balcony windows was measured. The windows installed were typical double window with thickness 16 mm or 22 mm. Measurements of the weighted standard sound pressure level difference showed a decrease of about 3 dB in sound insulation performance due to expansion. For common exterior noise levels of 70-85 dB(A), the indoor noise level can exceed 45 dB(A), the limit level regulated in Korea. However, it was found that the sound insulation performance of the window and the quality of the construction have more influence on indoor noise levels than balcony expansion itself.

학교주변 소음실태 분석에 관한 연구 -원주지역 학교를 중심으로- (A Study of Analysis on the Noise Aspect of School District -A Case Study of Wonju City-)

  • 가종길;이준대
    • 한국안전학회지
    • /
    • 제14권3호
    • /
    • pp.140-145
    • /
    • 1999
  • In this study, noise analyses were performed toward ten school and one library-building adjacent to road. In particular, noise levels measured in the case-study city were compared to those from environmental noise standard as well as to encouraged noise level. In the analyses, the following conclusions are emphasized in order to make comfortable educational learning environment. 1) When windows were open, the measured noise level of 9 schools exceeded the encouraged noise level. In order to mitigate the exceeded level, it is necessary to plant trees or lawn and install soundproofing wall. 2) When windows were closed, the measured noise level of the most schools showed lower than that of encouraged level. For sound insulation, installing both double window and casement window are required. 3) Schoolhouse's vertical arrangement from the road in order to minimize the expected noise effect, and provision of green space by which visual hiding as well as psychological comfort are presumably achieved.

  • PDF

Visual C++을 이용한 윈도우 운영체제 내의 파일 및 디렉토리 보안 기능 설계 (Design of files and directories with security features within the Windows O.S using Visual C++)

  • 장승주;김준호
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2009년도 춘계 종합학술대회 논문집
    • /
    • pp.510-514
    • /
    • 2009
  • 이 프로그램은 Visual C++로 개발되었으며, 윈도우 운영체제내에서 파일 및 디렉토리 보안 기능을 가지고 있다. 파일 및 디렉토리 보안은 암호화/복호화 작업으로 이루어지며 파일 보안은 키 값과 라운드수를 알아야 하고, 디렉토리 보안은 비밀번호를 알아야만 복호화 할 수 있도록 설계되었다. 또한 ECB, CBC 연산방식과 3DES, SEED 알고리즘방식을 지원하며, 암호화 시 .de0 이라는 실행할 수 없는 확장자의 파일로 만들어지면서 이중보안을 할 수 있도록 개발되었다.

  • PDF

유럽 집합주택을 대상으로 한 환경친화적 외피의 특성 분석 - 외피의 구축적 특성에 따른 유형별 분석을 중심으로 - (A Study on the Characteristics of Environment-friendly Skins of European Housing - Focused on the Structural Characteristics of the skins -)

  • 원현성;김진우;오세규
    • KIEAE Journal
    • /
    • 제8권1호
    • /
    • pp.11-18
    • /
    • 2008
  • The purpose of this study is to analyze application methods and structural characteristics of each element of environment-friendly European housing through classification of skin types. The results of the study are following. 1) The skins are classified by three types; single skin with multi layers, double skin with single layer and double skin with multi layers. 2) Most single skins with multi-layer are composed with wooden louvers, sun blinds and insulating windows. There are introduction of atrium and balcony, and variation sectional space composition according to cases. 3) There are two types of double skins; to put cavity between inner skin and outer skin and more extensional spaces such as balconies, corridors and stair halls. Solar walls and mechanical ventilators are often introduced to double skins with multi-layer. 4) The functions of the latest environment-friendly skins are vary from controllers and buffers of indoor environmental elements such as temperature, light, air and sound to equipments to perform essential functions to efficiently operate HVAC systems.

이중 및 삼중 로이창호의 일사획득에 따른 사무소건물의 냉난방에너지 성능분석 (Heating & Cooling Energy Performance Analysis of an Office Building according to SHGC level of the Double & Triple Glazing with Low-e Coating)

  • 김효중;박재성;신우철;윤종호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.90-95
    • /
    • 2008
  • An SHGC(Solar Heat Gain Coefficient) is a determinant of total flux of solar radiation coming indoor and a critical factor in evaluating heating and cooling load. U-value represents heat loss while SHGC denominates heat gain. Recently, windows with high solar gain, mid solar gain or low solar gain are being produced with the development of Low-E coating technology. This study evaluated changes in energy consumption for heating and cooling according to changes in SHGC when using double-layered Low-E glass and triple layered Low-E glass in relation to double layered clear glass as base glass. An Office was chosen for the evaluation. For deriving optical properties of each window, WINDOW 5 by LBNL, an U.S. based company. and the results were analyzed to evaluate performance of heat and cooling energy on anannual basis using ESP-r, an energy interpretation program. Compared to the energy consumption of the double layered clear glass, the double layered Low-E glass with high solar gain consumed $69.5kWh/m^2,yr$, 9% more than the double layered clear glass in cooling energy. The one with mid solar gain consumed $63.1kWh/m^2,yr$, 1% less than the base glass while the one with low solar gain consumed $57.6kWh/m^2,yr$, 10% less than the base glass. When it comes to tripled layered glass, the ones with high solar showed 2% of increase respectively while the one with mid solar gain and low solar gain resulted 5% and 11% in decrease in energy consumption due to low acquisition of solar radiation. With respect to cooling energy. it was found that the lower the SHGC. the less energy consumption becomes.

  • PDF

단열시트(뽁뽁이)의 종류 및 부착위치에 따른 창호의 단열성능 평가 (Thermal Performance Evaluation of the Window Systems with Air-bubble Sheets)

  • 황제;정아희;전병헌;안영철
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.463-467
    • /
    • 2015
  • The air-bubble sheet has been widely used to wrap fragile products for long-distance transportation. The further usage of the air-bubble sheet as a thermal-insulation material for the reduction of the thermal conductivities of window systems has occurred because of its low price, in addition to its thermal-conductivity properties. In this study, the thermal performances of a variety of commercial air-bubble sheets according to various applications were evaluated. The experiments were performed with single-glazed and double-glazed windows and three types of air-bubble sheets of different air volumes. U-values are used and were calculated for the determination of the thermal performances that are based on the KS F 2278. The maximum decrease of the U-value was measured as 1.092 when a sheet was attached onto the frame of single-glazed window. The square-like air-bubble sheet that contains the largest air volume shows the highest thermal-resistance value. Double layers of the air-bubble sheets show better performances than those of the single layers on both sides of the windows.

기혼 맞벌이 여성의 일-가족양립에 관한 연구 - 일-가족양립의 긍정적 전이, 비대칭성, 차별적 기능 검증을 중심으로 - (A Study on the Work-Family Reconciliation of Married Women in Double Income Households - With a focus on testing the positive spillover, asymmetry, and differential functions of work-family reconciliation -)

  • 문영주
    • 가족자원경영과 정책
    • /
    • 제17권1호
    • /
    • pp.81-102
    • /
    • 2013
  • The purpose of this study was to investigate the work-family reconciliation level of married women in double-income households. Specifically, the study aimed to test the positive spillover effects, asymmetry, and differential functions of work-family reconciliation. The study thus analyzed 1,114 married women in double-income households in the third-year data of the Korean Longitudinal Survey of Women and Families (KLoWF) done by Korean Women's Development Institute (KWDI), with the exception of those who were separated, divorced, or widowed from their husbands. The data were put to descriptive statistics, frequency analysis, and exploratory factor analysis using SPSS 20.0 for Windows. AMOS 20.0 was used to test the hypothesis on positive spillover effects, asymmetry, and differential functions. The analysis results confirm that work-family conflict, family-work conflict, work-family facilitation, and family-work facilitation are different concepts, thus supporting the hypothesis on positive spillover effects. Secondly, the negative effects of family on work were greater than those of work on family, whereas the positive effects of family on work were greater than those of work on family, which finding partially supported the hypothesis on asymmetry among the components of work-family reconciliation. Finally, the married women in double-income households with preschool children experienced more work-family conflict and family-work conflict than those with no preschool children, which result supported the hypothesis on differential functions between the two groups of women. The findings were combined to provide implications for the utilization of family resources, policies for work-family reconciliation, and plans for institutional supports to promote the work-family reconciliation of married women in double-income households.

  • PDF

Analysis of energy and daylight performance of adjustable shading devices in region with hot summer and cold winter

  • Freewan, Ahmed A.;Shqra, Lina W.
    • Advances in Energy Research
    • /
    • 제5권4호
    • /
    • pp.289-304
    • /
    • 2017
  • Large glazed surfaces and windows become common features in modern buildings. The spread of these features was influenced by the dependence of designers on mechanical and artificial systems to provide occupants with thermal and visual comfort. Countries with hot summer and cold winter conditions, like Jordan, require maximum shading from solar radiation in summer, and maximum exposure in winter to reduce cooling and heating loads respectively. The current research aims at designing optimized double-positioned external shading device systems that help to reduce energy consumption in buildings and provide thermal and visual comfort during both hot and cold seasons. Using energy plus, a whole building energy simulation program, and radiance, Lighting Simulation Tool, with DesignBuilder interface, a series of computer simulations for energy consumption and daylighting performance were conducted for offices with south, east, or west windows. The research was based on comparison to determine the best fit characteristics for two positions of adjustable horizontal louvers on south facade or vertical fins on east and west facades for summer and winter conditions. The adjustable shading systems can be applied for new or retrofitted office or housing buildings. The optimized shading devices for summer and winter positions helped to reduce the net annual energy consumption compared to a base case space with no shading device or with curtains and compared to fix shading devices.

로이유리 발코니 창호의 단열성능에 따른 공동주택 건축물 에너지효율등급 평가 연구 (A Study on Evaluation of the Building Energy Rating depending on the Thermal Performance of Balcony Window with Low-E glazing)

  • 이나은;안병립;장철용;이승복
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.58-63
    • /
    • 2012
  • As the exterior of building has been considered one of th important parts, the use of glass that is suitable to express various appearances gets raised. However, windows have 6~7times lower insulating performance than insulated walls. Lately, highly efficient windows are required as the needs for reduction of energy consumption come to the force. Therefore, Nowadays more people use cooling systems in summer, more the use of Low-E glazing is increasing. Because it is good to block Solar Radiant Energy which can cause much of heat loss while cooling system is working. This study measures U-value of the double Low-E glazing window and commonly used single Low-E glazing window. And then the effect of each window on the efficiency rating has been analyzed applying to the certification system of the building energy efficiency rating which has implemented.