• Title/Summary/Keyword: double probe

Search Result 131, Processing Time 0.02 seconds

Review paper: Application of the Pulsed Eddy Current Technique to Inspect Pipelines of Nuclear Plants

  • Park, D.G.;Angani, C.S.;Kishore, M.B.;Vertesy, G.;Lee, D.H.
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.342-347
    • /
    • 2013
  • Local wall thinning in pipelines affects the structural integrity of industries, such as nuclear power plants (NPPs). In the present study, a development of pulsed eddy current (PEC) technology that detects the wall thinning of pipelines covered with insulation is reviewed. The methods and experimental results, which have two kinds of probe with a single and double core, were compared. For this purpose, the single and double core probes having one and two excitation coils have been devised, and the differential probe with two Hall sensors has been fabricated to measure the wall thinning in insulated pipelines. The test sample is a stainless steel having different thickness, laminated by plastic insulation to simulate the pipelines in NPPs. The excitation coils in the probe is driven by a rectangular current pulse, the difference of two Hall sensors has been measured as a resultant PEC signal. The peak value of the detected signal is used to describe the wall thinning. The double core probe has better performance to detect the wall thinning covered with insulation; the single core probe can detect the wall thinning up to an insulation thickness of 18 mm, whereas the double probe can detect up to 25 mm. The results show that the double core PEC probe has the potential to detect the wall thinning in an insulated pipeline of the NPPs.

Relationship between Ambulatory 24-hour Double Probe pH Monitoring and Reflux Finding Score in Patients with LPR (인후두 역류환자에서 이동성 24시간 이중 탐침 산도 검사와 인후두 역류 소견 점수와의 상관관계)

  • Park, Young-Dae;Kang, Dae-Woon;Lee, Jin-Choon;Lee, Byung-Joo;Wang, Soo-Geun;Kim, Gwang-Ha
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.19 no.2
    • /
    • pp.136-141
    • /
    • 2008
  • Background and Objectives: Laryngopharyngeal reflux (LPR) is a very common disease among outpatients of department of otorhinolaryngology. Although there are several diagnostic tools for LPR disease and ambulatory 24-hour double-probe pH monitoring is gold standard method, empirical diagnosis by reflux symptom index and reflux finding score (RFS) are mainly used. So we analyzed the relationship between ambulatory 24-hour double-probe pH monitoring and RFS in patients with LPR. Subjective and Method: Fifty patients with LPR symptoms and abnormal RFS and ambulatory 24-hour double probe monitoring were enrolled. Each items and sum of laryngeal reflux score were compared the results of ambulatory 24-hour double-probe pH monitoring in upper (UES) and lower (LES) esophageal sphincter. Results: There were no significant correlation between the results of ambulatory 24-hour double-probe pH monitoring in UES (pH<4 and pH<5) and each item and sum of RFS. However, supine time and reflux number of UES (pH<5) were showed the partial correlations with diffuse laryngeal edema and thick endolaryngeal mucus (p=0.03, p=0.01). Although there were no relationship between the results of ambulatory 24-hour double-probe pH monitoring in LES and sum of RFS, the significant correlations presented between granuloma and total time (p=0.008), upright time (p=0.008, reflux number (p=0.049) of LES. Conclusion: Although granuloma among items of RFS showed significantly correlation with the results of ambulatory 24-hour double-probe pH monitoring in LES, there were no significant correlation between the results of ambulatory 24-hour double-probe pH monitoring in UES and LES and items and sum of RFS.

  • PDF

Narrow Resonant Double-Ridged Rectangular Waveguide Probe for Near-Field Scanning Microwave Microscopy

  • Kim, Byung-Mun;Son, Hyeok-Woo;Cho, Young-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.406-412
    • /
    • 2018
  • In this paper, we propose a narrow resonant waveguide probe that can improve the measurement sensitivity in near-field scanning microwave microscopy. The probe consists of a metal waveguide incorporating the following two sections: a straight section at the tip of the probe whose cross-section is a double-ridged rectangle, and whose height is much smaller than the waveguide width; and a standard waveguide section. The advantage of the narrow waveguide is the same as that of the quarter-wave transformer section i.e., it achieves impedance-matching between the sample under test (SUT) and the standard waveguide. The design procedure used for the probe is presented in detail and the performance of the designed resonant probe is evaluated theoretically by using an equivalent circuit. The calculated results are compared with those obtained using the finite element method (Ansoft HFSS), and consistency between the results is demonstrated. Furthermore, the performance of the fabricated resonant probe is evaluated experimentally. At X-band frequencies, we have measured the one-dimensional scanning reflection coefficient of the SUT using the probe. The sensitivity of the proposed resonant probe is improved by more than two times as compared to a conventional waveguide cavity type probe.

The Relationship Between Esophageal Manometry and 24 Hour Double Prove pH-metry with Gastroesophageal Reflax in Pharyrngeal Neurosis Patients. (인두신경증 환자에서 Esophageal manometry와 24hour double prove pH metry 검사 및 위식도 역류와의 관계)

  • 김선태
    • Korean Journal of Bronchoesophagology
    • /
    • v.2 no.1
    • /
    • pp.88-96
    • /
    • 1996
  • In recently the gastroesophageal reflux disease(GERD) has been known to induce the otolaryngologic manifestations. Pharyngeal neurosis is a disease which we could have not found the cause frequently. So we have studied the relation between the pharyngeal neurosis and the GERD among 50 patients who were diagnosed as pharyngeal neurosis after esophagogram and laryngoscopic examination. We performed esophageal manometry and 24hour double-probe pH-metry and then compared with normal control group(n=30). The results are as follows 1 Among 50 patients, 12(24%) patients were diagnosed as GERD by DeMeester scoring. 2. In esophageal manometry, the upper and lower esophageal sphincter between the patients and the control group have no significant difference(p>0.05) and 9 among 50 pateints showed abnormal peristaltic movement in esophageal body contraction. 3. In 24hour double-probe pH-metry, the esophageal probe showed that in GERD group(n= 12) the number of reflux episode, episodes greater than 5 minutes and the percentage of time

  • PDF

Developing 500 MHz NB 19F-13C Double Resonance Solid-State NMR Probe for in-situ Analysis of Liquid Crystal Display Panels

  • Choi, Sung-Sub;Jung, Ji-Ho;Park, Yu-Geun;Park, Tae-Joon;Park, Gregory Hyung-Jin;Kim, Yong-Ae
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.5
    • /
    • pp.1577-1580
    • /
    • 2012
  • The orientational and dynamic behavior of liquid crystal molecules on the alignment layer surfaces of liquid crystal display (LCD) devices is crucial to their performance, but there are only a few methods of experimentally elucidating the interactions between the liquid crystals and the alignment layers. Inspired by the natural and technical similarities between membrane proteins in lipid bilayers and liquid crystals in LCDs, we employed solid-state NMR methodologies originally developed for the study of membrane proteins in lipid bilayers for the in-situ analysis of liquid crystal display panels. In this article, we present a home-built 500 MHz narrowbore (NB) The orientational and dynamic behavior of liquid crystal molecules on the alignment layer surfaces of liquid crystal display (LCD) devices is crucial to their performance, but there are only a few methods of experimentally elucidating the interactions between the liquid crystals and the alignment layers. Inspired by the natural and technical similarities between membrane proteins in lipid bilayers and liquid crystals in LCDs, we employed solid-state NMR methodologies originally developed for the study of membrane proteins in lipid bilayers for the in-situ analysis of liquid crystal display panels. In this article, we present a home-built 500 MHz narrowbore (NB) $^{19}F-^{13}C$ double resonance solid-state NMR probe with a flat-square coil and the first application of this probe for the in-situ analysis of LCD panel samples. double resonance solid-state NMR probe with a flat-square coil and the first application of this probe for the in-situ analysis of LCD panel samples.

마이크로플라즈마 전류 스위치 및 응용

  • Chae, Gyeol-Yeo;Kim, Myeong-Min;Mun, Cheol-Hui;Lee, Sang-Yeon;Lee, Seung-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.433-433
    • /
    • 2010
  • A microplasma current switch (MPCS) for a device operated in a current mode like organic light-emitting diodes (OLEDs), which features matrix addressability and current switching, is presented as well as its architecture and operational principle. The MPCS utilizes the intrinsic memory and conductivity of plasmas to achieve matrix addressability and current switching. We have fabricated a $100\;mm\;{\times}\;100\;mm$ MPCS panel in which its cell pitch is $1080\;{\mu}m\;{\times}\;1080\;{\mu}m$. The matrix addressability and current switching were verified. In addition, the current-voltage (I-V) characteristic of the unit cell was measured when plasmas were ignited. In principle, the scheme of the MPCS is equivalent to that of a double Langmuir probe diagnosing plasma parameters except for their relative dimensions to a plasma volume. Accordingly, the I-V characteristic was analyzed by a double Langmuir probe theory, and the plasma density and electron temperature were estimated from the I-V curve using a collisional double Langmuir probe theory.

  • PDF

A Study on the Measurement of Magneto-Plasma Parameters by Probe Method (자화 플라즈마 파라메타 측정에 관한 연구)

  • Sung, Y.M.;Lee, C.Y.;Son, J.B.;Shin, J.H.;Kwak, Y.S.;Park, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.591-593
    • /
    • 1993
  • Magneto plasma has been widely used for controlled fusion and material processings such as etchings, depositions, and sputterings in the various fields. For controlling and guaranting the equipment, precision plasma parameters must be gained. In this experiment, using single probe and double probes, we investigated the effect of magnetic field on magneto plasma. As a result of this experiment, we found the fact that single probe was largely affected by magnetic field for measuring magneto plasma parameters, while double probe was not.

  • PDF

Double clad fiber probe for fluorescence spectroscopy

  • Wang, Ling;Lee, Byeong-Ha
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.07a
    • /
    • pp.35-36
    • /
    • 2007
  • We report a probe using a single double clad fiber (DCF) for fluorescence spectroscopy. Bidirectional separate transmission for excitation and fluorescence light in a single fiber was implemented. A DCF coupler made by side-polished method could extract none but the collected fluorescence signals propagating in inner cladding mode, thereby diminishing the interference of silica background generated by the excitation in core mode. The experimental results show that the fluorescence spectra of biological tissues obtained using the DCF probes have much less silica background than using a standard multiple-mode fiber.

  • PDF

Rapid and exact molecular identification of the PSP (paralytic shellfish poisoning) producing dinoflagellate genus Alexandrium

  • Kim, Choong-jae;Kim, Sook-Yang;Kim, Kui-Young;Kang, Young-Sil;Kim, Hak-Gyoon;Kim, Chang-Hoon
    • Proceedings of the Korean Aquaculture Society Conference
    • /
    • 2003.10a
    • /
    • pp.132-133
    • /
    • 2003
  • The marine dinoflagellate genus Alexandrium comprise PSP producing A. acatenella, A. angustitabuzatum, A. catenella, A. fundyense, A. minutum, A. ostenfezdii, A. tamiyavanichii and A. tamarense. In monitoring toxic Alexandrium, rapid and exact species identification is one of the significant prerequisite work, however we have suffered confusion of species definition in Alexandrium. To surmount this problem, we chose DNA probing, which has long been used as an alternative for conventional identification methods, primarily relying on morphological approaches using microscope in microbial field. Oligonucleotide DNA probes targeting rRNA or rDNA have been commonly used in diverse studies to detect and enumerate cells concerned as a culture-indetendent powerful tool. Despite of the massive literature on the HAB species containing Alexandrium, application of DNA probing for species identification and detection has been limited to a few documents. DNA probes of toxic A. tamarense, A. catenella and A. tamiyavanichii, and non-toxic A. affine, A. fraterculus, A. insuetum and A. pseudogonyaulax were designed from LSU rDNA D1-D2, and applied to whole cell-FISH. Each DNA probes reacted only the targeted Alexandrium cells with very high species-specificity within Alexandrium. The probes could detect each targeted cells obtained from the natural sea water samples without cross-reactivity. Labeling intensity varied in the growth stage, this showed that the contents of probe-targeted cellular rRNA decreased with reduced growth rate. Double probe TAMID2S1 achieved approximately two times higher fluorescent intensity than that with single probe TAMID2. This double probe did not cross-react with any kinds of microorganisms in the natural sea waters. Therefore we can say that in whole-cell FISH procedure this double DNA probe successfully labeled targeted A. tamiyavanichii without cross-reaction with congeners and diverse natural bio-communities.

  • PDF

Three Dimensional Flow Structure under Rotating Stall in an Axial Flow Fan (주기적 선회실속이 발성하는 축류홴의 3차원 유동구조)

  • Kang, Chang Sik;Shin, You Hwan;Kim, Kwang Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.105-110
    • /
    • 2002
  • Experimental study was conducted to reveal the instability such as leakage flow and rotating stall in an axial flow fan. For this study, unsteady total pressure probe and multi-hole pressure probe were specially designed for measuring the flow field upstream and downstream of rotor. The measured pressure signal was analyzed by Single and Double Phase Locked Averaging Technique. From the result of total pressure fields at inlet and outlet of the rotor, the useful information on the structure of the stall cell in radial direction was provided. Also, detailed flow measurements were carried out with a specially designed high frequency multi-hole pressure probe, providing some insight to the leakage flow and their interation.

  • PDF