• Title/Summary/Keyword: dose equivalent

Search Result 528, Processing Time 0.025 seconds

Intensity Modulated Radiation Therapy Commissioning and Quality Assurance: Implementation of AAPM TG119 (세기조절방사선치료(IMRT)의 Commissioning 및 정도관리: AAPM TG119 적용)

  • Ahn, Woo-Sang;Cho, Byung-Chul
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.99-105
    • /
    • 2011
  • The purpose of this study is to evaluate the accuracy of IMRT in our clinic from based on TG119 procedure and establish action level. Five IMRT test cases were described in TG119: multi-target, head&neck, prostate, and two C-shapes (easy&hard). There were used and delivered to water-equivalent solid phantom for IMRT. Absolute dose for points in target and OAR was measured by using an ion chamber (CC13, IBA). EBT2 film was utilized to compare the measured two-dimensional dose distribution with the calculated one by treatment planning system. All collected data were analyzed using the TG119 specifications to determine the confidence limit. The mean of relative error (%) between measured and calculated value was $1.2{\pm}1.1%$ and $1.2{\pm}0.7%$ for target and OAR, respectively. The resulting confidence limits were 3.4% and 2.6%. In EBT2 film dosimetry, the average percentage of points passing the gamma criteria (3%/3 mm) was $97.7{\pm}0.8%$. Confidence limit values determined by EBT2 film analysis was 3.9%. This study has focused on IMRT commissioning and quality assurance based on TG119 guideline. It is concluded that action level were ${\pm}4%$ and ${\pm}3%$ for target and OAR and 97% for film measurement, respectively. It is expected that TG119-based procedure can be used as reference to evaluate the accuracy of IMRT for each institution.

The Effects of Image Quality due to Scattering X-ray according to increasing Patient Thickness (피사체 두께에 따른 산란선 발생이 화질에 미치는 영향)

  • Park, Ji-Koon;Yang, Sung-Woo;Jun, Jae-Hoon;Cho, Su-Yeon;Kim, Kyo-Tae;Heo, Ye-Ji;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.671-677
    • /
    • 2017
  • In this study, scattering factors affecting the quality of medical images were quantitatively analyzed and investigated. MCNPX simulation was conducted by using ANSI phantom, made of tissue equivalent materials, to calculate the scattering ratio occurred by the increase of the object thickness. Then, the result of the simulation was compared with the result of actual radiation measurement. In addition, we evaluated the image quality by the RMS evaluation, RSD and NPS analysis using X-ray images acquired with increasing object thickness. Furthermore, the scattering ratio was analyzed by increasing the thickness of acrylic phantom on chest phantom. The result showed that the scattering ratio was increased to 57.2%, 62.4%, and 66.8% from 48.9%, respectively, when the acrylic phantom thickness was increased by 1 inch from 6.1 inches. The results of MCNPX simulation and the actual measured scattering dose showed similar results. Also, as a result of RMS measurement from acquired x-ray images, the standard deviation decreased as the object thickness increased. However, in the RSD analysis considering the average incident dose, the results were increased from 0.028 to 0.039, 0.051, 0.062 as the acrylic phantom thickness was increased from 6.1 inches to 7.1 inch, 8.1 inch, and 9.1 inch, respectively. It can be seen that the increase of the scattering effect due to the increase of the object thickness reduces the SNR. Also, the NPS results obtained by measuring scattered radiation incident on the detector resulted in the increase of the noise as the object thickness increased.

Difference in the Set-up Margin between 2D Conventional and 3D CT Based Planning in Patients with Early Breast Cancer (조기유방암환자의 이차원치료계획과 삼차원치료계획의 방사선조사범위의 차이)

  • Jo, Sun-Mi;Chun, Mi-Son;Kim, Mi-Hwa;Oh, Young-Taek;Kang, Seung-Hee;Noh, O-Kyu
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.177-183
    • /
    • 2010
  • Purpose: Simulation using computed tomography (CT) is now widely available for radiation treatment planning for breast cancer. It is an important tool to help define the tumor target and normal tissue based on anatomical features of an individual patient. In Korea, most patients have small sized breasts and the purpose of this study was to review the margin of treatment field between conventional two-dimensional (2D) planning and CT based three-dimensional (3D) planning in patients with small breasts. Materials and Methods: Twenty-five consecutive patients with early breast cancer undergoing breast conservation therapy were selected. All patients underwent 3D CT based planning with a conventional breast tangential field design. In 2D planning, the treatment field margins were determined by palpation of the breast parenchyma (In general, the superior: base of the clavicle, medial: midline, lateral: mid - axillary line, and inferior margin: 2 m below the inframammary fold). In 3D planning, the clinical target volume (CTV) ought to comprise all glandular breast tissue, and the PTV was obtained by adding a 3D margin of 1 cm around the CTV except in the skin direction. The difference in the treatment field margin and equivalent field size between 2D and 3D planning were evaluated. The association between radiation field margins and factors such as body mass index, menopause status, and bra size was determined. Lung volume and heart volume were examined on the basis of the prescribed breast radiation dose and 3D dose distribution. Results: The margins of the treatment field were smaller in the 3D planning except for two patients. The superior margin was especially variable (average, 2.5 cm; range, -2.5 to 4.5 cm; SD, 1.85). The margin of these targets did not vary equally across BMI class, menopause status, or bra size. The average irradiated lung volume was significantly lower for 3D planning. The average irradiated heart volume did not decrease significantly. Conclusion: The use of 3D CT based planning reduced the radiation field in early breast cancer patients with small breasts in relation to conventional planning. Though a coherent definition of the breast is needed, CT-based planning generated the better plan in terms of reducing the irradiation volume of normal tissue. Moreover it was possible that 3D CT based planning showed better CTV coverage including postoperative change.

Treatment Outcome and Analysis of the Prognostic Factors of High Grade Glioma Treated by Postoperative Radiotherapy (고악성도 신경아교종의 수술 후 방사선 치료 성적과 예후인자 분석)

  • Lee, Sun-Min;Park, Young-Je;Yoon, Won-Sup;Lee, Suk;Yang, Dae-Sik;Jeong, Yong-Gu;Kim, Chul-Yong
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.117-124
    • /
    • 2010
  • Purpose: To analyze the postoperative radiotherapy results and prognostic factors in patients with WHO grade 3 and 4 gliomas. Materials and Methods: A total of 99 patients with malignant gliomas who underwent postoperative radiotherapy between 1988 and 2007 were enrolled in this study. Total resections, subtotal resections ($\geq$50%), partial resections (<50%), and biopsies were performed in 16, 38, 22, and 23 patients, respectively. In total there were 32, 63 and 4 WHO grade 3, 4, and unspecified high grade gliomas, respectively. The biologically equivalent dose was in the range of 18.6 to $83.3\;Gy_{10}$ (median dose, $72.2\;Gy_{10}$). We retrospectively analyzed survival rate, patterns of failure, prognostic factors, and adverse effects. Results: The median follow-up time was 11 months and there were 54 patients (54.5%) with local failure. The one and 2-year survival rates were 56.6% and 29.3%, respectively, and the median survival duration was 13 months. The one and 2-year progression-free survival rates (PFS) were 31.3% and 18.2%, respectively, and the median PFS was 7 months. The prognostic factors for overall survival were age (p=0.0001), surgical extents (subtotal resection, p=0.023; partial resection, p=0.009; biopsy only, p=0.002), and enhancement of tumor in postoperative imaging study (p=0.049). The factors affecting PFS were age (p=0.036), tumor enhancement of the postoperative imaging study (p=0.006). There were 3 patients with grade 3 and 4 side effects during and after radiotherapy. Conclusions: In addition to age and surgical extents, tumor enhancement of the postoperative imaging study was included in the prognostic factors. The most common relapse patterns were local failures and hence, additional studies are needed to improve local control rates.

Study on the calibration phantom and metal artifacts using virtual monochromatic images from dual energy CT (듀얼 에너지 CT의 가상 단색 영상을 이용한 영상 교정 팬텀과 금속 인공음영에 관한 연구)

  • Lee, Jun seong;Lee, Seung hoon;Park, Ju gyung;Lee, Sun young;Kim, Jin ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.77-84
    • /
    • 2017
  • Purpose: To evaluate the image quality improvement and dosimetric effects on virtual monochromatic images of a Dual Source-Dual Energy CT(DS-DECT) for radiotherapy planning. Materials and Methods: Dual energy(80/Sn 140 kVp) and single energy(120 kVp) scans were obtained with dual source CT scanner. Virtual monochromatic images were reconstructed at 40-140 keV for the catphan phantom study. The solid water-equivalent phantom for dosimetry performs an analytical calculation, which is implemented in TPS, of a 10 MV, $10{\times}10cm^2$ photon beam incident into the solid phantom with the existence of stainless steel. The dose profiles along the central axis at depths were discussed. The dosimetric consequences in computed treatment plans were evaluated based on polychromatic images at 120 kVp. Results: The magnitude of differences was large at lower monochromatic energy levels. The measurements at over 70 keV shows stable HU for polystyrene, acrylic. For CT to ED conversion curve, the shape of the curve at 120 kVp was close to that at 80 keV. 105 keV virtual monochromatic images were more successful than other energies at reducing streak artifacts, which some residual artifacts remained in the corrected image. The dose-calculation variations in radiotherapy treatment planning do not exceed ${\pm}0.7%$. Conclusion: Radiation doses with dual energy CT imaging can be lower than those with single energy CT imaging. The virtual monochromatic images were useful for the revision of CT number, which can be improved for target coverage and electron densities distribution.

  • PDF

Some Characteristics of Teflon-Thermoluminescent Dosimeters (테프론 열형광선량계(熱螢光線量計)의 특성(特性))

  • Lee, Soo-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.7 no.1
    • /
    • pp.23-33
    • /
    • 1982
  • The characteristic thermoluminescence responses of Teflon thermoluminescent dosimeters to radiations have been studied by the variation of radiation qualities as well as the high dose radiations. The change in the sensitivity of TLDs for different radiation qualities were studied through not only the photon energy dependence but also the change of supralinearity on the photon energy dependence, by exposing $^{60}Co$ gamma rays, the effective X-rays of 44keV, 69keV, 108keV, and thermal neutron of 0.04 eV. The results were as the following: The TL response of $T-CaSO_4$: Dy as a function of absorbed dose was linear up to about 5 Gy, and the response beyond 5Gy was supralinear for $^{60}Co$ gamma rays. The supralinearity of T-LiF-7 became noticeably apparent more than that of $T-CaSO_4$:Dy and also the lower the LET of radiation became the higher the supralinear effects were. No supralinearity appeared for the thermal neutron irradiations equivalent to 10Gy of $^{60}Co$ gamma rays. The relative sensitivities (Rs), which depended on the doses of $^{60}Co$ gamma rays to the TLDs of T-LiF-7 and T-$CaSO_4$:Dy could be, respectively, approximated to the following empirical formula fitted by the least square method: $$R_{LiF}=1.021-0.04581\;logD+0.402(logD)^2-0.405(logD)^3,\;\;5{\times}10^3{\geq}D{\geq}1(Gy)$$ $$R_{CaSO_4}=0.976-0.3241\;logD+0.262(logD)^2-0.298(logD)^3,\;5{\times}10^3{\geq}D{\geq}1(Gy)$$.

  • PDF

Antioxidant and Anti-inflammatory Activities of Water and the Fermentation Liquid of Sea Tangle (Saccharina japonica) (다시마 물 추출액과 발효액의 항산화 및 항염증 활성)

  • Jung, Kyung Im;Kim, Bo Kyung;Kang, Jeong Hyeon;Oh, Geun Hye;Kim, In Kyung;Kim, Mihyang
    • Journal of Life Science
    • /
    • v.29 no.5
    • /
    • pp.596-606
    • /
    • 2019
  • The study investigated the physiochemical properties and the antioxidant and anti-inflammatory activities of the sea tangle (Saccharina japonica) in a water extract before (STWE) and after (STFL) fermentation with Lactobacillus brevis. The pH values of STWE and STFL were 6.18 and 4.16, and the sugar contents were $8.50^{\circ}Brix$ and $7.40^{\circ}Brix$, respectively. The main free amino acids of STWE and STFL were glutamic acid, aspartic acid, and alanine, and the ${\gamma}$-amino butyric acid (GABA) content was increased by fermentation. The total polyphenol contents of STWE and STFL were 498.29 and 615.77 mg gallic acid equivalent (GAE)/ml, respectively. The 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging activities of STWE and STFL were markedly increased in a dose-dependent manner, and revealed about 89.89% and 96.94% activities, respectively, at 10% concentration (p<0.05). The superoxide dismutase (SOD) activities of STWE and STFL were also markedly increased in a dose-dependent manner, and the activity of STFL was significantly increased when compared with STWE (p<0.05). The anti-inflammatory activity was examined in lipopolysaccharide (LPS)-stimulated RAW 264.7 cells. STWE and STFL decreased the production of reactive oxygen species (ROS), which had levels of about 189.90% and 174.69% at 1% concentration, respectively (p<0.05). The contents of pro-inflammatory cytokines, such as tumor necrosis factor-alpha ($TNF-{\alpha}$) and interleukin-6 (IL-6), were decreased more by addition of STFL than by addition of STWE. The STWE and STFL showed high antioxidant and anti-inflammatory activity, and these activities were increased by fermentation. Therefore, sea tangle extracts can be used as functional food materials.

The Study of Radiation Reducing Method during Injection Radiopharmaceuticals (방사성의약품 투여 시 피폭선량 저감에 대한 연구)

  • Cho, Seok-Won;Jung, Seok;Park, June-Young;Oh, Shin-Hyun;NamKoong, Hyuk;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.80-85
    • /
    • 2012
  • Purpose: The whole body bone scan is an examination that visualizing physiological change of bones and using bone-congenial radiopharmaceutical. The patients are intravenous injected radiopharmaceutical which labeled with radioactive isotope ($^{99m}Tc$) emitting 140 keV gammarays and scanned after injection. The 3 principles of radiation protection from external exposureare time, distance and shielding. On the 3 principles of radiation protection basis, radiopharmaceutical might just as well be injected rapidly for reducing radiation because it might be the unopened radiation source. However the radiopharmaceuticals are injected into patient directly and there is a limitation of distance control. This study confirmed the change of radiation exposure as change of distance from radiopharmaceutical and observed the change of radiation exposure afte rsetting a shelter for help to control radio-technician's exposure. Materials & methods: For calculate the average of injection time, the trained injector measured the injection time for 50 times and calculated the average (2 minutes). We made a source as filled the 99mTc-HDP 925 MBq 0.2 mL in a 1 mL syringe and measured the radiation exposure from 50 cm,100 cm,150 cm and 200 cm by using Geiger-Mueller counter (FH-40, Thermo Scientific, USA). Then we settled a lead shielding (lead equivalent 6 mm) from the source 25 cm distance and measured the radiation exposure from 50 cm distance. For verify the reproducibility, the measurement was done among 20 times. The correlation between before and after shielding was verified by using SPSS (ver. 18) as paired t-test. Results: The radiation doses according to distance during 2 minutes from the source without shielding were $1.986{\pm}0.052{\mu}$ Sv in 50 cm, $0.515{\pm}0.022{\mu}$ Sv in 100 cm, $0.251{\pm}0.012{\mu}$ Sv in 150 cm, $0.148{\pm}0.006{\mu}$ Sv in 200 cm. After setting the shielding, the radiation dose was $0.035{\pm}0.003{\mu}$ Sv. Therefore, there was a statistical significant difference between the radiation doses with shielding and without shielding ($p$<0.001). Conclusion: Because the great importance of whole body bone scan in the nuclear medicine, we should make an effort to reduce radiation exposure during radiopharmaceutical injections by referring the principles of radiation protection from external exposure. However there is a limitation of distance for direct injection and time for patients having attenuated tubules. We confirmed the reduction of radiation exposure by increasing distance. In case of setting shield from source 25 cm away, we confirmed reducing of radiation exposure. Therefore it would be better for reducing of radiation exposure to using shield during radiopharmaceutical injection.

  • PDF

Studies on the red-yellow soil in Honam rolling area - Improvement of soil fertility - (호남야산(湖南野山)에 분포(分布)하고 있는 적황색(赤黃色)에 관(關)한 연구(硏究) - 토양비옥도(土壤肥沃度) 증진(增進)에 관(關)하여 -)

  • Chae, Sang Suk;Chang, Young Sun;Lee, Hwa Soo;Hong, Chong Woon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.7 no.1
    • /
    • pp.29-34
    • /
    • 1974
  • On a newly reclamed acidic Song-jong soil (soil of a member of fine loamy, mesic family of Hapludults) an experiment was carried out to find out the proper measure of the improvement of soil fertility with soybean as test crop. Results are summarized as follow: 1. Application of compost (1 ton/10a), lime (lime requirement)and fused phosphate (equivalent to 5% of the phosphate fixation coefficient)resulted in the increase of soybean yield by 93.3% over the check plot (N: 6kg/10a, $P_2O_5$: 9kg/10a, $K_2O$: 6kg/10a). The application of fused phosphate at the level of 5% of phosphate fixation coefficient N (6kg/10a) and K(6kg/10a) brought the yield increase by 62.7% over the check plot. However, although the pH of the soil was adjusted to 7.0 by liming, the application of lime with moderate dose of phosphate ($P_2O_5$: 9kg/10a) did not increase the yield of soybean significantly. And the application of fused phosphate at the level of 5% of phosphate fixation coefficient increased the available soil P from 14 ppm to around 100 ppm as tested after harvest. 2. Application of compost (1 ton/10a) increased the organic matter content of soil by 0.8% when tested after harvest. While, the application of rice straw (0.5 ton/10a) did not alter the soil organic matter content. The CEC of the soil tested after havest found incereased significantly by the addition of lime and compost. 3. Plant analysis revealed that the $K_2O/Ca+Mg$ is better correlated with the yield than the absolute concentration of $K_2O$ in plant tissue. Between the concentration of $P_2O_5$ in plant tissue and the yield of soybean, a typical C-curve relationship was observed, indicating that in this particular soil, phosphate was the primary growth liming factor.

  • PDF

Comparison of Enalapril Maleate Tablets on Bioavailability and the Time Course of Inhibition of Plasma Angiotensin-Converting Enzyme (Enalapril Maleate 정제의 동등성에 관한 연구 ; 약동학적 성상 및 혈장 ACE 활성도 억제 효과)

  • Jang, In-Jin;Jang, Byung-Soo;Shin, Sang-Goo;Shin, Jae-Gook;Rho, Il-Kun;Lee, Kyeong-Hun;Park, Chan-Woong
    • The Korean Journal of Pharmacology
    • /
    • v.26 no.2
    • /
    • pp.219-226
    • /
    • 1990
  • Enalapril maleate tablets of two different producers were tested for bioequivalence. Enalapril is rapidly metabolized to an active metabolite, enalaprilat which inhibits angiotensin-converting enzyme (ACE). The pharmacokinetics of enalapril maleate and the time course of inhibition of plasma ACE activity after administration of the drugs were studied. Two single doses of 10mg each of enalapril maleate were administered orally to twelve male volunteers in a balanced, randomized, two-way crossover investigation. Plasma enalaprilat concentrations were determined over a 23-hour after the dose by enzyme inhibition assay and enalapril by the same method following in vitro hydrolysis. Urinary recoveries of enalapril and enalaprilat were determined for the calculation of renal clearance. Plasma ACE activity was determined by an enzyme assay. Peak plasma levels of enalapril were observed about 1 hour after the doses, and practically all enalapril had disappeared from plasma within 6 hour. Peak enalapril concentrations of both formulations were almost identical ($Vasotec^{\circledR}$, 61.38 ng/ml; $Beartec^{\circledR}$, 64.27 ng/ml). The values of the pharmacokinetic parameters of enalaprilat computed for $Vasotec^{\circledR}$ and $Beartec^{\circledR}$ tablets are presented in that order; area under the curve=330.63:320.96 $ng{\cdot}hr/ml$; peak concentration=38.63:39.43 ng/ml; time to peak=3.83:4.08 hour; elimination half-life=3.95:3.92 hours. No statistically significant difference was detected when area under the curve and all other parameters were compared. Using criteria of 95% confidence interval for the comparison of these parameters, only the upper limits of area under the curve and time to peak of enalapril were over 120%. All the parameters of enalaprilat were acceptable. Percent inhibition of plasma ACE to plasma enalaprilat concentration showed the sigmoid concentration-inhibition relationship. Time courses of plasma ACE inhibition after the administration of both formulations were quite similar. The formulations were found to be equivalent when compared on the premise that no significant difference was detected when pharmacokientic parameters and inhibition of ACE activity were compared, based on the confidence limits analysis.

  • PDF