• 제목/요약/키워드: divided electrodes

검색결과 66건 처리시간 0.026초

Voltammetric Determination of Cobalt(Ⅱ) Using Carbon Paste Electrodes Modified with 1-(2-Pyridylazo)-2-naphthol

  • 배준웅;박유철;이상학;전우성;장혜영
    • Bulletin of the Korean Chemical Society
    • /
    • 제17권11호
    • /
    • pp.995-999
    • /
    • 1996
  • A method for the determination of cobalt(Ⅱ) by differential pulse voltammetry using a carbon paste electrode constructed by incorporating 1-(2-pyridylazo)-2-naphthol(PAN) into a conventional carbon paste mixture composed of graphite powder and Nujol oil has been developed. Several influencing factors for the determination of cobalt(Ⅱ) were studied in detail and the optimum analytical conditions were found to be as follows: pH, 4.6; composition of electrode, 20%; temperature of deposition, 43 ℃; time of preconcentration, 15 min. Regeneration of the electrode surface for the continuous uses of the electrode was achieved by exposing the carbon paste electrode to an acidic solution. Response of the electrode was reproducible for the uses of five times and the relative standard deviations were 6.7 and 4.6% for 2.0×10-5 M and 4.0×10-6 M cobalt(Ⅱ), respectively. The calibration curve for cobalt(Ⅱ) obtained by differential pulse voltammetry was divided into two linear ranges of 1.7× 10-6-1.3×10-4 M and 2.0×10-7-8.0×10-7 M. The detection limit was estimated to be 1.3×10-7 M. The effects of coexisting ions were also investigated to test the applicability of the proposed method to the determination of cobalt(Ⅱ) in real samples.

치과용 주조 합금의 방전가공에 따른 표면 성분 변화 (Elemental alteration of the surface of dental casting alloys induced by electro discharge machining)

  • 장용철;이명곤
    • 대한치과기공학회지
    • /
    • 제31권1호
    • /
    • pp.55-61
    • /
    • 2009
  • Passive fitting of meso-structure and super-structures is a predominant requirement for the longevity and clinical success of osseointegrated dental implants. However, precision and passive fitting has been unpredictable with conventional methods of casting as well as for corrective techniques. Alternative to conventional techniques, electro discharge machining(EDM) is an advanced method introduced to dental technology to improve the passive fitting of implant prosthesis. In this technique material is removed by melting and vaporization in electric sparks. Regarding the efficacy of EDM, the application of this technique induces severe surface morphological and elemental alterations due to the high temperatures developed during machining, which vary between $10,000{\sim}20,000^{\circ}C$. The aim of this study was to investigate the morphological and elemental alterations induced by EDM process of casting dental gold alloy and non-precious alloy used for the production of implant-supported prosthesis. A conventional clinical dental casting alloys were used for experimental specimens patterns, which were divided in three groups, high fineness gold alloy(Au 75%, HG group), low fineness gold alloy(Au 55%, LG group) and nonprecious metal alloy(Ni-Cr, NP group). The UCLA type plastic abutment patterns were invested with conventional investment material and were cast in a centrifugal casting machine. Castings were sandblasted with $50{\mu}m\;Al_2O_3$. One casting specimen of each group was polished by conventional finishing(HGCON, LGCON, NPCON) and one specimen of each group was subjected to EDM in a system using Cu electrodes, kerosene as dielectric fluid in 10 min for gold alloy and 20 min for Ni-Cr alloy(HGEDM. LGEDM, NOEDM). The surface morphology of all specimens was studied under an energy dispersive X-ray spectrometer (EDS). The quantitative results from EDS analysis are presented on the HGEDM and LGEDM specimens a significant increase in C and Cu concentrations was found after EDM finishing. The different result was documented for C on the NPEDM with a significant uptake of O after EDM finishing, whereas Al, Si showed a significant decrease in their concentrations. EDS analysis showed a serious uptake of C and Cu after the EDM procedure in the alloys studied. The C uptake after the EDM process is a common finding and it is attributed to the decomposition of the dielectric fluid in the plasma column, probably due to the development of extremely high temperatures. The Cu uptake is readily explained from the decomposition of Cu electrodes, something which is also a common finding after the EDM procedure. However, all the aforementioned mechanisms require further research. The clinical implication of these findings is related with the biological and corrosion resistance of surfaces prepared by the EDM process.

  • PDF

AC PDP에서 휘도효율을 향상시키기 위하여 자기소거 방전을 발생시키는 새로운 구동방법 (A New Driving Method Generating Self-Erasing Discharge to Improve Luminous Efficiency in AC PDP)

  • 조병권
    • 전자공학회논문지
    • /
    • 제51권2호
    • /
    • pp.168-172
    • /
    • 2014
  • 교류형 플라즈마 디스플레이에서 유지기간 중에 자기소거 방전을 발생시켜서 휘도효율을 향상시키기 위한 새로운 유지 구동방법이 제안된다. 일반적인 AC PDP에서 하나의 서브필드 시간은 초기화, 기입, 유지기간으로 나누어져 있다. 그 중 유지기간 동안에 2개의 상판 전극인 X와 Y 전극에 교대로 사각 유지파형이 인가되어 화상을 표시하기 위한 유지기간 중의 플라즈마 방전이 연속적으로 발생된다. 그러나 일반적인 구동방법에 있어서 하판의 A전극에는 기입기간에서 종래의 구동방법에서는 셀을 선택할 때만 기입파형이 구동되고 유지기간 중에는 접지 상태로 놓여있으므로 유지 방전에 관여하지 않는다. 본 실험에서는 유지기간 중에 자기소거 방전을 발생시켜 휘도효율을 상승시키기 위하여 유지펄스의 뒷부분에서 음의 펄스를 A전극에 인가하였다. A전극의 음의 펄스는 주 유지방전이 발생된 후 셀 내부의 공간전하들을 벽전하로 전환시켜서 3전극의 전위가 접지 상태가 될 때 재 축적된 벽전하로 인하여 방전을 한번 더 유도시켰다. 그 결과, 유지기간 중 A 전극의 전압 높이에 따른 휘도 효율을 측정하였고 최적의 구동전압을 적용했을 때 휘도효율을 측정한 결과 종래와 비교해서 약 40 % 향상되었다.

Eugenol, Capsaicin과 Demethoxy - NE가 치수동통 반응에 미치는 영향 (EFFECTS OF EUGENOL, CAPSAICIN AND DEMETHOXY-NE ON THE PAIN RESPONSE OF DENTAL PULP)

  • 이은구;이정식
    • Restorative Dentistry and Endodontics
    • /
    • 제17권1호
    • /
    • pp.10-21
    • /
    • 1992
  • The purpose of this study was to investigate the analgesic effect of eugenol, capsaicin and demethoxy-NE. Young adult cats, weighing 2.0 to 3.0kg, were used. Each animal was anesthetized (${\alpha}$-chloralose 60mg per kg body weight) and divided into four groups; control, eugenol, capsaicin and demethoxy-NE group. The anterior digastric muscles were exposed and a pair of electrodes was inserted to record the electromyograms. To expose the pulp, each canine teeth was prepared with a low speed bur under cooling and used for recording anterior digastric muscular EMGs evoked by noxious stimulation of dental pulp. To observe effects on jaw opening reflex, inferior alveolar nerve of both sides were exposed for drug application and wire electrodes were inserted in anterior digstric muscle for recording the EMGs. To observe effects on action potential, saphenous nerves of both sides were exposed and three tissue pools were made from surrounding tissue. The most distal pool was used for applying stimulation, the most proximal one for recording of action potential, and the other one for drug application. One side of inferior alveolar nerve and saphenous nerve were used for eugenol, capsaicin, or demethoxy-NE application, the other side of nerve for control experiments(only vehicle application). Anterior digastric muscular EMGs evoked by noxious stimulation of dental pulp were recorded before drug application, immediate after drug application, at 60 and 120 minutes, and 5 days after drug application. Action potentials were recorded before drug application, immediate after 30 minutes drug application, at 30, 60 and 120 minutes after drug had been washed out. The results were as follows; 1. Eugenol had a continuous blocking effect on the anterior digastric muscular EMGs evoked by noxious pulp stimulation and after 5 days, showed completely blocking effect. 2. After 5 days, demethoxy-NE applied to dental pulp had a considerable blocking effect on the jaw opening retlex evoked by noxious stimulation but capsaicin had no significant effect. 3. After 5 days, eugenol group showed the strongest blocking effect among the all experimental groups on the jaw opening reflex evoked by noxious stimulation of dental pulp and capsaicin group showed the weakest blocking effect. 4. Eugenol had a completely blocking effect on the action potential conductivity of peripheral nerve. Capsaicin and demethoxy-NE had the blocking effect on the action potential conductivity of ${\alpha}$-and C-nerve fibers. 5. Capsaicin, demethoxy-NE and eugenol applied to inferior alveolar nerve surppressed the jaw opening reflex evoked by noxious stimulation of dental pulp.

  • PDF

Binary Harmony Search 기반의 EEG 채널 그룹화를 이용한 다중 자극에 반응하는 뇌파 신호의 특성 연구 (Brain Wave Characteristic Analysis by Multi-stimuli with EEG Channel Grouping based on Binary Harmony Search)

  • 이태주;박승민;심귀보
    • 제어로봇시스템학회논문지
    • /
    • 제19권8호
    • /
    • pp.725-730
    • /
    • 2013
  • This paper proposed a novel method for an analysis feature of an Electroencephalogram (EEG) at all channels simultaneously. In a BCI (Brain-Computer Interface) system, EEGs are used to control a machine or computer. The EEG signals were weak to noise and had low spatial resolution because they were acquired by a non-invasive method involving, attaching electrodes along with scalp. This made it difficult to analyze the whole channel of EEG signals. And the previous method could not analyze multiple stimuli, the result being that the BCI system could not react to multiple orders. The method proposed in this paper made it possible analyze multiple-stimuli by grouping the channels. We searched the groups making the largest correlation coefficient summation of every member of the group with a BHS (Binary Harmony Search) algorithm. Then we assumed the EEG signal could be written in linear summation of groups using concentration parameters. In order to verify this assumption, we performed a simulation of three subjects, 60 times per person. From the simulation, we could obtain the groups of EEG signals. We also established the types of stimulus from the concentration coefficient. Consequently, we concluded that the signal could be divided into several groups. Furthermore, we could analyze the EEG in a new way with concentration coefficients from the EEG channel grouping.

TCD를 이용한 뇌혈류속도 측정: 간섭전류의 효과 (Cerebral Blood Flow Velocity Measurement by TCD: The Effects of Interferential Current)

  • 이문환;한종만
    • The Journal of Korean Physical Therapy
    • /
    • 제17권2호
    • /
    • pp.126-147
    • /
    • 2005
  • TCD(transcranial doppler, TCD) units is a equipment that measure a blood flow velocity in the middle cerebral artery(MCA), anterior cerebral artery(ACA), posterior cerebral artery(PCA), and vertebral artery(VA). The aim of this study was to determine the influence on cerebral blood flow velocity according to different stimulation frequency of interferential currents. 50 patients who has a cervical pain were participated in this study and randomly divided into one of the three experimental, placebo, and control group: (1)IFS 1; $10{\sim}30Hz$ was applied, (2)IFS 2; $30{\sim}50Hz$ was applied, (3)IFS 3; $50{\sim}100Hz$ was applied, (4)placebo; suction only applied, and (5)control; neither suction nor interferential stimulation applied. In the IFS groups, interferential stimulations were applied through four suction electrodes application from the 5th cervical to the 1st thoracic level. The results were as follow; 1. MCA was statistically significant with IFS 1, IFS 2, IFS 3, and Placebo group(p<0.05), But there was no statistical significance between IFS 1 and IFS 3 group(p>0.05). 2. ACA was statistically significant with IFS 1, IFS 2, and IFS 3 group(p<0.05). And IFS 1 was more statistical significance than IFS 3 group on ACA(p<0.05). 3. PCA was statistically significant with IFS 1, IFS 2, and IFS 3 group(p<0.05). And IFS 1 was more statistical significance than IFS 3 group on PCA(p<0.05). 4. VA was statistically significant with IFS 1, IFS 2, and IFS 3 group(p<0.05). And IFS 1 was more statistical significance than IFS 3 group on VA(p<0.05).

  • PDF

전기자극 수준이 정상 성인의 자율신경계에 미치는 영향 (The Effect of Electrical Stimulation Level on Autonomic Nerve System in Normal Adults)

  • 진희경;조성현
    • 한국산학기술학회논문지
    • /
    • 제16권3호
    • /
    • pp.2029-2037
    • /
    • 2015
  • 본 연구의 목적은 척수분절레벨에 적용한 간섭전류의 자극수준에 따른 정상성인의 자율신경계에 미치는 영향을 알아보고자 하였다. 간섭전류는 T1-T4 분절에 접착식 패드전극을 2극 배치 후 20분간 전기자극하여, 전기자극 전과 후, 30분 후의 변화를 확인하였다. 연구대상은 광주시에 소재한 N대학교에 다니는 건강한 성인남녀 45명을 대상으로 감각자극수준은 100 bps, 10~12 mA, 운동자극수준은 5 bps, 45~50 mA, 유해자극수준은 100 bps, 80~90 mA으로 각각 15명씩 무작위 배치하여 연구를 수행하였으며 연구 결과는 다음과 같다. 각 집단의 교감신경활성도의 변화는 시간과 집단 간의 상호작용에 유의한 차이가 없었으나, 시간에 따라 유의한 변화를 보여주었다(p<.05). 사후 분석결과 전기자극 직후와 전기자극 후 30분에서 유의한 차이를 보여주었다(p<.05). 각 집단의 부교감신경활성도의 변화는 시간과 집단 간의 상호작용에 유의한 차이가 없었으나, 시간에 따라 유의한 변화를 보여주었다(p<.05). 사후 분석결과 전기자극 직후와 전기자극 후 30분에서 유의한 차이를 보여주었다(p<.05). 이상의 결과로 전기자극 수준은 특정목적과 상황에 따라 다양하게 적용되어야 할 것으로 생각된다.

유두체가 제거된 흰쥐의 정위반응 (Orienting Response of Rats Following Damage to the Mammillary Bodies)

  • 김종규;김철
    • The Korean Journal of Physiology
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1972
  • A study was planned to see if the mammillary bodies have any influence upon orienting response Thirty-nine male rats were divided into two groups. One group of animals received electrolytic lesion of the mammillary bodies through stereotaxically implanted electrodes (mammillary body group), and the other group received the same treatment short of electrolytic lesion(operated control group). All animals were tested for orienting response 3 weeks after surgery. Orienting response was regarded as elicited when an animal in alertness ceased ongoing activity upon 1,000 Hz tone presentation and/or turned head toward the source of stimulus. Weak (momentary and inconspicuous) and strong (marked and more persistent) responses were discriminated. Occurrence and duration of orienting response were measured, and the rate of habituation was estimated in 20 trials. Shift of attention from sound to light stimulus (10 trials) as well as orienting response of thirsty animals to sound stimulus while drinking (5 trials) and while at rest (5 trials) were also tested. 1. Simple orienting respons to sound stimulus tended to occur more often and its duration tended to be shorter in the mammillary body group than in the operated control group. 2. With repetition of trials, the occurrence of orienting response in each trial decreased progressively in both groups (habituation). However, the rate of habituation was significantly less prominent in the mammillary body group than in the operated control group. 3. Under attention·shift situation, orienting response tended to occur less often and its duration tended to be shorter in the mammillary body group than in the operated control group. 4. Orienting response to sound stimulus while drinking to quench thirst tended to occur more often and its duration tended to be shorter in the mammillary body group than in the operated control group. In quiet state, however, there existed no group difference with regard to the occurrence and duration of the orienting response. Although no obvious inference can be drawn from the above results, they may suggest the mammillary bodies being involved in the orienting response as a control mechanism inhibitory to the occurrence and facilitatory to the habituation of the response.

  • PDF

플라즈마 에쳐용 실리콘 전극과 링의 수명에 미치는 결함의 영향 (Effect of defects on lifetime of silicon electrodes and rings in plasma etcher)

  • 음정현;채정민;피재환;이성민;최균;김상진;홍태식;황충호;안학준
    • 한국결정성장학회지
    • /
    • 제20권2호
    • /
    • pp.101-105
    • /
    • 2010
  • 플라즈마 에쳐 내에 사용되는 실리콘 전극과 링 부품은 사용 중에 강한 플라즈마와 접촉하면서 주기적인 가열과 냉각 과정을 거친다. 이 때 부품의 표면에서는 열 응력으로 인하여 PSB라고 하는 띠 형상의 결함이 생성되며 이로 인하여 그 수명을 다하게 된다. 원료인 실리콘 잉곳의 관점에서 그 수명에 미치는 인자를 살펴보았다. 잉곳의 등급, 즉 S/F와 S/A에 따라 불순물과 결함의 농도를 GDMS와 ${\mu}$-PCD로 평가하여 잉곳의 어떤 요소들에 의하여 수명이 결정되는가를 분석하였다. 그 결과, {001} 면상에서 관찰되는 <110> 방향의 면 결함들이 PSB와 연결될 가능성이 있음을 제안하였다.

뇌파를 이용한 두개천골요법 기반 베개의 수면유도 효과 검증 (Evaluation of Cranial Sacral Therapy (CST) Based Pillow on Sleep Induction Using the Electroencephalogram (EEG))

  • 권혁찬;표정빈;박용길;이현주;태기식
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권1호
    • /
    • pp.55-61
    • /
    • 2018
  • The purpose of this study was to investigate the effect of a pillow simulated with cranial sacral therapy (CST) on sleep induction using electroencephalography (EEG). This study included 12 voluntary participants divided into experimental group (CST group) and control group (Non-CST group) to observe EEG changes. The position of the electrode for EEG measurement consists of 8 channels electrodes (Fp1, Fp2, F3, F4, T3, T4, P3 and P4). In this study, we measured the fall asleep time, change of brain activity and sleep wave ratio using EEG wave (${\delta}$, ${\theta}$, ${\alpha}$, ${\beta}$ and ${\gamma}$). As a result, the mean fall asleep time of the experimental group was shorter than that of the control group significantly (p < 0.001). Also in comparison with the control group, both the delta (d) and theta (q) wave corresponding to the slow waves showed a larger increase and the alpha (a) wave showed a larger decrease significantly. The slow waves of experimental group showed a higher rate of significant increase than the control group (p < 0.001). Therefore this study showed that pillow based on CST had an effective in improving sleep induction and quality.