• Title/Summary/Keyword: distortion sensitivity

Search Result 97, Processing Time 0.023 seconds

Development of Liquid Metal Strain Gauge for Measuring WT Blade's Deformation (풍력발전기 블레이드 변형 측정을 위한 액체금속 스트레인 게이지 개발)

  • Park, In Kyum;Seo, Youngho;Kim, Byeong Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.3
    • /
    • pp.307-314
    • /
    • 2015
  • In this paper, the embedding type novel liquid metal strain gauge was developed for measuring the deformation of wind turbine blades. In general, the conventional methods for the SHM have many disadvantages such as frequency distortion in FBG sensors, the low gauge factor and mechanical failures in strain gauges and extremely sophisticated filtering in AE sensors. However, the liquid metal filled in a pre-confined micro channel shows dramatic characteristics such as high sensitivity, flexibility and robustnes! s to environment. To adopt such a high feasibility of the liquid metal in flexible sensor applications, the EGaIn was introduced to make flexible liquid metal strain gauges for the SHM. A micro channeled flexible film fabricated by the several MEMS processes and the PDMS replication was filled with EGaIn and wire-connected. Lots of experiments were conducted to investigate the performance of the developed strain gauges and verify the feasibility to the actual wind turbine blades health monitoring.

Experimental Structural Dynamic Modification of Fixture for Vibration Testing (진동시험용 치구의 실험적 구조변경 설계)

  • 정의봉;오영세;김준엽
    • Journal of KSNVE
    • /
    • v.8 no.1
    • /
    • pp.180-186
    • /
    • 1998
  • Vibration test fixture is used in random vibration control testing. The specified reference spectrum should be transmitted equally to the specimen attachment points on the fixture. In most practical cases, however, spectrum at each of specimen attachment points may be quite different from the specified reference spectrum because of the dynamic characteristics of vibration test fixture. This paper proposes the method of experimental dynamic modification of fixture system for vibration test so that the reference spectrum can be transmitted to the specimen attachment points without distortion. The stiffness of mounts of specimen and the thickness of fixture are considered as design variables. The frequency response functions of specimen used for input data are obtained from vibration testing, and the frequency response functions of fixture are obtained from finite element modeling. The sensitivities of frequency response functions at specimen attachment points to the mount stiffness are derived from synthesis method of transfer function. And the sensitivities to the thickness of fixture are also derived from finite element modeling. The presented method is verified by computer simulation and vibration testing.

  • PDF

Measurement and Analysis of Electric Field near 345/154kV UHV Overhead Transmission Lines and Substations (345/154kV 초고압 송변전설비 주변에서의 전장의 측정과 분석)

  • Lee, J.G.;Ahn, C.H.;Lee, B.H.;Kil, G.S.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1861-1863
    • /
    • 1996
  • In this paper, measurements and analyses of ELF electric fields in the vicinity of UHV overhead transmission lines and substations have been conducted. Planar-type sensors have been developed with special consideration of picking up lower frequency and spatial components without any distortion. So finally the electric field measuring system has the frequency bandwidth of 7[Hz] to 2.7[MHz] and the response sensitivity of 0.094[mV/V/m]. A brief description of design rules of the measuring system and measurement procedures is introduced. The actual survey near 154 and 345[kV] overhead transmission lines and power subststions was carried out and analyzed. It may be inferred from these results that the electric field intensity exeeds 7[kV/m] only in very few cases particularly at the substations so that the field measurements meet almost limits or guidelines that various authorized international institutes recommend.

  • PDF

Measurement and Analysis of Magnetic Field near 345/154kV UHV Overhead Transmission Lines and Substations (345/154kV 초고압 송변전설비 주변에서의 자장의 측정과 분석)

  • Lee, J.G.;Ahn, C.H.;Lee, B.H.;Kil, G.S.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1813-1815
    • /
    • 1996
  • With the three dimensional magnetic field measuring system dealt with in this paper, accurate measurements and analyses of ELF magnetic fields in the vicinity of UHV overhead transmission lines and substations have been conducted. For the field measurements multiturn loop-type sensors have been developed with special consideration of taking lower frequency and spatial components without any distortion. So the measuring system has the frequency bandwidth of 8[Hz] to about 53[kHz] and the response sensitivity of $9.88[mV/{\mu}T]$ in average. A brief description of design rules of the measuring system and measurement procedures is given. The actual surrey near 154 and 345[kV] overhead transmission lines and power subststions was carried out and analyzed. It may be inferred from these results that the maximum magnetic field intensities under typical UHV overhead transmission lines do not exceed $20[{\mu}T]$ so that the field measurements satisfy sufficiently all limits or guidelines that various authorized international institutes recommend.

  • PDF

Dependency of COD on ground motion intensity and stiffness distribution

  • Aschheim, Mark;Maurer, Edwin;Browning, JoAnn
    • Structural Engineering and Mechanics
    • /
    • v.27 no.4
    • /
    • pp.425-438
    • /
    • 2007
  • Large changes in stiffness associated with cracking and yielding of reinforced concrete sections may be expected to occur during the dynamic response of reinforced concrete frames to earthquake ground shaking. These changes in stiffness in stories that experience cracking might be expected to cause relatively large peak interstory drift ratios. If so, accounting for such changes would add complexity to seismic design procedures. This study evaluates changes in an index parameter to establish whether this effect is significant. The index, known as the coefficient of distortion (COD), is defined as the ratio of peak interstory drift ratio and peak roof drift ratio. The sensitivity of the COD is evaluated statistically for five- and nine-story reinforced concrete frames having either uniform story heights or a tall first story. A suite of ten ground motion records was used; this suite was scaled to five intensity levels to cause varied degrees of damage to the concrete frame elements. Ground motion intensity was found to cause relatively small changes in mean CODs; the changes were most pronounced for changes in suite scale factor from 0.5 to 1 and from 1 to 4. While these changes were statistically significant in several cases, the magnitude of the change was sufficiently small that values of COD may be suggested for use in preliminary design that are independent of shaking intensity. Consequently, design limits on interstory drift ratio may be implemented by limiting the peak roof drift in preliminary design.

Performance Improvement of PMSM Current Control using Gain Attenuation and Phase Delay Compensated LPF (이득 감쇠 및 위상 지연 보상 LPF를 이용한 PMSM의 전류 제어 성능 개선)

  • Kim, Minju;Choi, Chinchul;Lee, Wootaik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.2
    • /
    • pp.107-114
    • /
    • 2014
  • This paper applies a compensated low pass filter (LPF) to current measurements for permanent magnet synchronous motor (PMSM) drives. The noise limits the bandwidth of current controllers and has more adverse influences on control performances under the light load condition because of the low signal-to-noise ratio. In order to eliminate the noise sensitivity, this paper proposes a digital LPF with a compensator of gain attenuation and phase delay which are unacceptable in current information for PMSM drives. Characteristics of the proposed LPF are analyzed in comparison with the general LPFs. The compensated LPF is basically designed by the orthogonal property of the measured currents in the ${\alpha}{\beta}$ stationary reference frame. In addition, an implementation issue of the proposed method is discussed. Experimental results using the proposed method show improvements of the current control performance from two perspectives, rapid step responses and reductions of harmonic distortion.

The Measurements of Vibration Displacement of the Piezoelectric Exciter Using Mach-Zehnder Optical Fiber Interferometer (Mach-Zehnder 광섬유 간섭계를 이용한 압전형 진동발생기의 동특성 조사)

  • Cho, Seung-Il;Kim, Sung-Boo;Lee, Jong-Kyu;Lee, Yong-Bong;Lee, Doo-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.10 s.115
    • /
    • pp.1044-1049
    • /
    • 2006
  • The vibration exciter with the accurate calibration requires a low distortion along a single axis over a wide range of frequency. The fabricated piezoelectric exciter was composed of a base, piezoelectric element(Venitron PZT 5A), electrode and seismic mass. Its performance characteristics is evaluated the Mach-Zehnder optical fiber interferometer. The phase of the optical wave passing through the optical fiber around the piezoelectric element was related the vibrational amplitude with a change of the applied sinusoidal voltage on the piezoelectric element. The dynamic characteristics of vibration exciter can be obtained by measuring the vibrational amplitude with a sinusoidal applied voltage on the piezoelectric element. The sensitivity of the fabricated piezoelectric exciter had a 0.4 nm/V which was uniform up to 20 kHz.

Possible Role of Disorder on Magnetostructural Transition in La1-xBaxMnO3

  • Kim, N.G.;Jung, J.H.
    • Journal of Magnetics
    • /
    • v.12 no.3
    • /
    • pp.103-107
    • /
    • 2007
  • Magnetic field induced structural transition has been systematically investigated for $La_{1-x}Ba_xMnO_3$ with the fine control of carrier doping $(0.15{\leq}x{\leq}0.20)$. Application of a magnetic field results in the suppression of the rhombohedral-orthorhombic transition temperature $(T_s)$ and the increase of insulator-metal transition temperature $(T_{MI})$. Near x = 0.17, where $T_S$ is similar to $T_{MI}$ at zero magnetic field, we found that the $T_S$ smoothly decreased with magnetic field even though it intersected the $T_{MI}$ near 3 T. Also, the magnetostructural phase diagram obtained from the temperature sweep and from the magnetic field sweep is not significantly modified. By comparing the magnetostructural transition in $La_{1-x}Sr_xMnO_3$, we have suggested that the large disorder originated from ionic size differences between La and Ba may weaken the sensitivity of the kinetic energy of $e_g$ electrons on the degree of lattice distortion in $La_{1-x}Ba_xMnO_3$.

A Study on the Harmonics Effect of Ratio Differential Relay for Transformer Protection (변압기 보호용 비율차동계전기의 고조파 영향에 관한 연구)

  • Kim, Kyung-Chul;Hwang, Young-Rok;Kho, Hun;Jung, Dong-Won;Chung, Hae-Sung;Lee, Dong-Wook;Jeong, Chae-Ho;Lee, Jae-Yoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.99-105
    • /
    • 2014
  • Power transformers are applied throughout the power system to connect systems of different voltage to one another. Since a ratio differential relay offers high sensitivity in detection of internal faults in power transformers, it is widely used in the main protection system. The use of nonlinear devices such as rectifiers and other devices utilizing solid state switching have been increased in industry during recent years. For nonlinear loads, the load current is not proportional to the instantaneous voltage. This situation creates harmonic distortion on the system. The harmonic could differential relay misoperation if not recognized. This paper aims at analyzing and probing into the influences of harmonics on a ratio differential relay for power transformer protection.

Digital Watermarking of JPEG Image Based on Human Visual System (인간 시각 시스템에 기반 한 JPEG 영상의 디지털 워터마킹)

  • Bae, Sung-Ho
    • The KIPS Transactions:PartB
    • /
    • v.11B no.2
    • /
    • pp.125-132
    • /
    • 2004
  • In this paper, a watermark inserting method according to the sensitivity of human visual system and minimizing distortion of original DCT coefficients in DCT transform domain is proposed. The proposed method inserts a more robust watermark in the insensitive block of human vision by reordering the blocks according to the human visual system which is appropriate to the JPEG image compression. It also enhances the invisibility and robustness in high compression rate in terms of the watermark inserting method within the block which minimizes distortions of original DCT coefficients. The computer simulation results show that the proposed method maintains high image quality and good robustness in high compression rate compared with conventional watermarking method.