• Title/Summary/Keyword: distortion sensitivity

Search Result 97, Processing Time 0.022 seconds

An Analysis on Performance Degradation of Silicon Photomultipliers over Temperatures Variation for PET-MR Application (PET-MR 시스템에 적용을 위한 실리콘 광증배센서의 온도 변화에 따른 성능 열화 분석)

  • Park, Kyeongjin;Kim, Hyoungtaek;Lim, Kyungtaek;Cho, Minsik;Kim, Giyoon;Cho, Gyuseong
    • Journal of Radiation Industry
    • /
    • v.9 no.3
    • /
    • pp.143-151
    • /
    • 2015
  • A PET-MR system is particularly useful in diagnosing brain diseases. We have developed a prototype positron emission tomography (PET) system which can be inserted into the bore of a whole-body magnetic resonance imaging (MRI) system that enables us to obtain PET and MRI images simultaneously with a reduced cost. Silicon photomultipliers (SiPM) are appropriated as a PET detector at PET/MR system because detectors have a high gain and are insensitive to magnetic fields. Despite of its improved performance compared to that of PMT-based detectors, there is a problem of the photo-peak channel shift which is due to the increase of the temperature inside the ring detector. This problem will occur decreasing sensitivity of the PET and image distortion. In this paper, I quantitative analyze parameters of the KAIST SiPM depending on temperature by experiments. And I designed cooling methods in consideration of the degradation of sensors for correction of the temperature in the PET gantry. According to this research, we expect that distortive images and degradation of the sensitivity will not be occurred with using the above idea to reduce heat even if the PET system operates for a long time.

Quantification of nonlinear seismic response of rectangular liquid tank

  • Nayak, Santosh Kumar;Biswal, Kishore Chandra
    • Structural Engineering and Mechanics
    • /
    • v.47 no.5
    • /
    • pp.599-622
    • /
    • 2013
  • Seismic response of two dimensional liquid tanks is numerically simulated using fully nonlinear velocity potential theory. Galerkin-weighted-residual based finite element method is used for solving the governing Laplace equation with fully nonlinear free surface boundary conditions and also for velocity recovery. Based on mixed Eulerian-Lagrangian (MEL) method, fourth order explicit Runge-Kutta scheme is used for time integration of free surface boundary conditions. A cubic-spline fitted regridding technique is used at every time step to eliminate possible numerical instabilities on account of Lagrangian node induced mesh distortion. An artificial surface damping term is used which mimics the viscosity induced damping and brings in numerical stability. Four earthquake motions have been suitably selected to study the effect of frequency content on the dynamic response of tank-liquid system. The nonlinear seismic response vis-a-vis linear response of rectangular liquid tank has been studied. The impulsive and convective components of hydrodynamic forces, e.g., base shear, overturning base moment and pressure distribution on tank-wall are quantified. It is observed that the convective response of tank-liquid system is very much sensitive to the frequency content of the ground motion. Such sensitivity is more pronounced in shallow tanks.

The development of intrusion sensor using the variations of speckle patterns (스페클 패턴을 이용한 침입자 센서의 개발)

  • 엄년식;김요희;양승국;오상기;박재희;강신원
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.119-122
    • /
    • 2000
  • The speckle pattern is formed by laser light from a multimode optical fiber. The speckle fluctuation is the result of interference among propagation modes when the optical fiber is subjected to a mechanical distortion at any point along its length. The experiments were carried on for the study of the feasibility of producing an intrusion detection system using the speckle fluctuation. The speckle fluctuation signals were monitored at real time by an oscilloscope which was connected with an amplifier and a filter. The experiment results showed that the intrusion sensor had enough sensitivity to detect an intruder.

  • PDF

Improvement of Characteristics of DMB SIR-type Bandpass Filter Using LTCC (LTCC를 이용한 DMB용 SIR형 대역통과 필터의 특성 개선)

  • Kim, Kyoung-Min;Park, Sung-Kyo;Lim, Byoung-Hwan;Ko, Hyang-Guh-Ri;Park, Chong-Baek
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.131-134
    • /
    • 2005
  • Recently, RF systems have rapidly grown with the extension of the mobile communication service The mobile service companies are providing the satellite broadcasting and common usage are expected. Coinciding with current trend, the development of improved satellite DMB (Digital Multimedia Broadcasting) tuner is required. To improve the receiving sensitivity under the poor communication circumstance, It is necessary to design the LNA (Low Noise Amplifier) with outstanding low noise characteristic and the BPF (Bandpass Filter) to transmit only desired signal without distortion and loss. Besides high reliability, the miniaturization and lightweight are required for design of mobile terminals. In this study, we designed and fabricated DMB SIR-type BPF which operates at 2642 MHz and is embedded in the substrate using LTCC. As a result, we obtained the passband insertion loss of 2.4 dB and the passband ripple of 0.08 dB. So this DMB SIR-type BPF is applicable to RF module of a satellite DMB tuner.

  • PDF

DEVELOPMENT OF A CRYOGENIC TESTING SYSTEM FOR MID-INFRARED DETECTORS ON SPICA

  • Nishiyama, Miho;Kaneda, Hidehiro;Ishihara, Daisuke;Oseki, Shinji;Takeuchi, Nami;Nagayama, Takahiro;Wada, Takehiko
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.355-357
    • /
    • 2017
  • For future space IR missions, such as SPICA, it is crucial to establish an experimental method for evaluating the performance of mid-IR detectors. In particular, the wavelength dependence of the sensitivity is important but difficult to be measured properly. We are now preparing a testing system for mid-IR Si:As/Si:Sb detectors on SPICA. We have designed a cryogenic optical system in which IR signal light from a pinhole is collimated, passed through an optical filter, and focused onto a detector. With this system, we can measure the photoresponse of the detector for various IR light using optical filters with different wavelength properties. We have fabricated aluminum mirrors which are adopted to minimize thermal distortion effects and evaluated the surface figure errors. The total wavefront error of the optical system is $1.3{\mu}m$ RMS, which is small enough for the target wavelengths ($20-37{\mu}m$) of SPICA. The point spread function measured at a room temperature is consistent with that predicted by the simulation. We report the optical performance of the system at cryogenic temperatures.

Evaluation of Dose Distribution of 6 MV X-ray using Optical Dosimetry (광 도시메트리시스템을 이용한 치료용 6 MV X선 선량분포 평가)

  • Kim, Sunghwan
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.925-932
    • /
    • 2019
  • In this paper, we developed optical dosimetry system with a plastic scintillator, a commercial 50 mm, f1.8 lens, and a commercial high-sensitivity CMOS (complementary metal-oxide semiconductor) camera. And, the correction processors of vignetting, geometrical distortion and scaling were established. Using the developed system, we can measured a percent depth dose, a beam profile and a dose linearity for 6 MV medical LINAC (Linear Accelerator). As results, the optically measured percent depth dose was well matched with the measured percent depth dose by ion-chamber within 2% tolerance. And the determined flatness was 2.8%. We concluded that the optical dosimetry system was sufficient for application of absorbed dose monitoring during radiation therapy.

Research on the Influence of Inter-turn Short Circuit Fault on the Temperature Field of Permanent Magnet Synchronous Motor

  • Qiu, Hongbo;Yu, Wenfei;Tang, Bingxia;Yang, Cunxiang;Zhao, Haiyang
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1566-1574
    • /
    • 2017
  • When the inter-turn short circuit (ITSC) fault occurs, the distortion of the magnetic field is serious. The motor loss variations of each part are obvious, and the motor temperature field is also affected. In order to obtain the influence of the ITSC fault on the motor temperature distribution, firstly, the normal and the fault finite element models of the permanent magnet synchronous motor (PMSM) were established. The magnetic density distribution and the eddy current density distribution were analyzed, and the mechanism of loss change was revealed. The effects of different forms and degrees of the fault on the loss were obtained. Based on the loss analysis, the motor temperature field calculation model was established, and the motor temperature change considering the loop current was analyzed. The influence of the fault on the motor temperature distribution was revealed. The sensitivity factors that limit the motor continuous operation were obtained. Finally, the correctness of the simulation was verified by experiments. The conclusions obtained are of great significance for the fault and high temperature demagnetization of the permanent magnet analysis.

Facture Behavior Analysis of Box Culvert Specimen Using Non-local Damage Model (비국소 손상모델을 이용한 전력구 모형 실험체의 파괴거동 해석)

  • Kwon, Yong-Gil;Woo, Sang-Kyun;Han, Sang-Hoon;Song, Young-Cheul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.225-228
    • /
    • 2008
  • In case of nonlinear analysis for reinforced concrete structure, the characteristics of the failure, which are depend on loading conditions, such as tension splitting, compression crushing and shear distortion should be considered. On the analytical evaluation for the failure behavior of these, the finite element techniques is the most widely used. After the maximum load, however, an analytical results by finite element technique are depending on the size of the element. In this study, integral nonlocal model which is one of those study for overcoming the element sensitivity and dependancy, used for the failure analysis of box culvert specimen. Comparing on the experimental and analytical results, validity and reliability of integral nonlocal model are investigate.

  • PDF

A PLC-Based Optical Sub-assembly of Triplexer Using TFF-Attached WDM and PD Carriers

  • Han, Young-Tak;Park, Yoon-Jung;Park, Sang-Ho;Shin, Jang-Uk;Kim, Duk-Jun;Park, Chul-Hee;Park, Sung-Woong;Kwon, Yoon-Koo;Lee, Deug-Ju;Hwang, Wol-Yon;Sung, Hee-Kyung
    • ETRI Journal
    • /
    • v.28 no.1
    • /
    • pp.103-106
    • /
    • 2006
  • We have fabricated a planar lightwave circuit (PLC) hybrid-integrated optical sub-assembly of a triplexer using a thin film filter (TFF)-attached wavelength division multiplexer (WDM) and photodiode (PD) carriers. Two types of TFFs were attached to a diced side of a silica-terraced PLC platform, and the PD carriers with a $45^{\circ}$ mirror on which pin-PDs were bonded were assembled with the platform. A clear transmitter eye-pattern and minimum receiver sensitivity of -24.5 dBm were obtained under 1.25 Gb/s operation for digital applications, and a second-order inter-modulation distortion (IMD2) of -70 dBc was achieved for an analog receiver.

  • PDF

Image of Transparency expressed in Dress (복식에 표현된 투명성의 이미지)

  • 박명희
    • Journal of the Korean Society of Costume
    • /
    • v.50 no.2
    • /
    • pp.111-123
    • /
    • 2000
  • This study compares architecture with dress, investigates the image of transparency expressed in modern dress, and reveals its modern meaning. That is the purpose for this study. The study results are as follows. First, purity was expressed with simple, white color which has not any exaggeration or decoration, and transparent veils of wedding dress express clean and pure image which represents the original meaning of wedding dress. Second, eroticism conveys being erotic by exposing human body through transmission of light over transparent materials. Eroticism expressed by wearing thin and transparent dress with body-conscious line almost like being nude or emphasizing the sexually curious area in human body. The biggest difference in this study is that eroticism is delivered in dress, but not in architecture. Third, playfulness shows synchronism which recognizes human body with transmission of light over ,linear, transparent materials or recognizes inside dress. Playfulness expressed with location switch between inside and outside, exaggeration, distortion , and emphasis. Forth , openness makes dress atmosphere soft by putting transparent materials over opaque materials, expressed separation from restriction by wearing transparent dress over a naked human body, and expressed open ad free image by expressing human emancipation and freedom. Transparent dress expressed modern human being's sensitivity desire for living with light and joyful mood departing from heavy through, and also open and free image which pursues for freedom of human boedy departing from the restriction of human body.

  • PDF