Facture Behavior Analysis of Box Culvert Specimen Using Non-local Damage Model

비국소 손상모델을 이용한 전력구 모형 실험체의 파괴거동 해석

  • 권용길 (충북대학교, 건설기술연구소) ;
  • 우상균 (한국전력연구원, 환경구조연구소, 구조부지그룹) ;
  • 한상훈 (충북대학교, 토목공학과) ;
  • 송영철 (한국전력연구원, 환경구조연구소, 구조부지그룹)
  • Published : 2008.11.07

Abstract

In case of nonlinear analysis for reinforced concrete structure, the characteristics of the failure, which are depend on loading conditions, such as tension splitting, compression crushing and shear distortion should be considered. On the analytical evaluation for the failure behavior of these, the finite element techniques is the most widely used. After the maximum load, however, an analytical results by finite element technique are depending on the size of the element. In this study, integral nonlocal model which is one of those study for overcoming the element sensitivity and dependancy, used for the failure analysis of box culvert specimen. Comparing on the experimental and analytical results, validity and reliability of integral nonlocal model are investigate.

철근콘크리트 구조물을 해석하는 경우, 하중조건 및 이들 하중의 증가에 따라 나타나게 되는 상이한 거동 특성들 즉, 인장균열, 압축파괴, 다축상태일 때의 강도의 증가, 전단파괴 시의 취성적 파괴특성 등을 반드시 고려해야만 한다. 유한요소법에 의한 해석적 평가 시, 최대하중 이후에는 요소크기에 따라 상이한 구조응답을 나타내는 요소의존적인 응답결과를 보인다. 본 연구에서는 이러한 요소의존성을 극복하기 위한 연구결과들 중 하나인 적분형 비국소화 모델을 이용하여 전력구 모형 실험체의 파괴거동을 해석하였다. 실험결과와 해석결과를 비교하여 적분형 비국소 모델의 신뢰성과 타당성을 검토하는 것을 목적으로 한다.