• Title/Summary/Keyword: dissipation constant

Search Result 242, Processing Time 0.024 seconds

A Study on the Properties of $SiO_2$ Thin Films using Sol-Gel Method (솔젤벱에 의해 제작된 $SiO_2$ 박막의 물성에 관한 연구)

  • You Do-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.11
    • /
    • pp.561-565
    • /
    • 2004
  • SiO₂ thin films are fabricated using sol-gel method and dipping method. Gelation time is faster according to increasing the amount of H₂O except H₂O/Si(OC₂H/sub 5/)₄=4. Initial viscosity is highest at H₂O/Si(OC₂H/sub 5/)₄=6. Gelation time is faster according to increasing the amount of CH₃COOH. The relative dielectric constant of thin films decreases a little according to increasing the measuring frequency. The dielectric dissipation factor of thin films increases a little below 100kHz and it increases rapidly over 100kHz.

Residue Dissipation Patterns of Neonicotinoid Acetamiprid and Thiamethoxam in Swiss Chard for the Harvest Periods under Greenhouse Conditions (시설재배 근대 중 Neonicotinoid계 살충제 Acetamiprid 및 Thiamethoxam의 생산단계 잔류특성)

  • Chang, Hee-Ra;You, Jung-Sun;Do, Jung-Ah
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.2
    • /
    • pp.97-103
    • /
    • 2018
  • BACKGROUND: Dissipation of acetamiprid and thiamethoxam in greenhouse grown chard samples was evaluated at 5 intervals including the pre-harvest interval after application. This study was conducted to determine the residue levels, the biological half-lives and dissipation rate of acetamiprid and thiamethoxam in chard under controlled conditions. METHODS AND RESULTS: Acetamiprid and thiamethoxam were applied in accordance with good agricultural practices for chard. Chard samples were collected at 0, 1, 2, 3, 5, 7, 10 and 14 days after application. Quantitaion was performed by HPLC-DAD system with C18 column. Limit of quantification (LOQ) of acetamiprid and thiamethoxam were both 0.02 mg/kg for chard. The recovery of acetamiprid and thiamethoxam were 77.8~107.5% and 94.3~108.6% at two concentration levels. The half-lives of pesticide dissipation in chard for two fields were 11.9 and 8.2 days for acetamiprid and 3.6 and 3.3 days for thiamethoxam respectively. The dissipation rate of acetamiprid and thiamethoxam were estimated according to the statistics method with a 95% confidence. CONCLUSION: Dissipation of acetamiprid and thiamethoxam in chard were determined under greenhouse. The concentration of acetamiprid and thiamethoxam in chards at 0 days after application were below specified by Korean MRL. Dissipation rate constant will be useful to set the pre-harvest residue limit for public health and consumer protection.

Dielectric Properties of Epoxy Composites with Varying Frequency (에폭시 복합체의 주파수 변화에 따른 유전특성)

  • Lee, Ho-Shik
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.676-682
    • /
    • 2018
  • In order to study electrical properties of epoxy composites with various frequency. To measure of dielectric characteristics have been performed over a frequency range from 30[Hz] to 3[MHz] and a temperature range of $20[^{\circ}C]$, $100[^{\circ}C]$, $140[^{\circ}C]$. We observed values of dielectric constant and dissipation of the epoxy composites with various frequency. We were observed dielectric loss and dispersion in low frequency region. Also, we observed to decrease of the dielectric constant due to the effects of filler in high temperature region.

Effects on Impedance Mismatch by Dk Variation with Operating Frequency (동작 주파수에 따른 Dk의 변화가 임피던스 부정합에 미치는 영향)

  • Lee, Jong-Hak;Kim, Chang-Gyun;Ra, Young-Eun;Lee, Keon-Min;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1473-1476
    • /
    • 2019
  • Accurate material information is very important in PCB (Printed Circuit Board) design. In an integrated mast of a battleship, heat reduction is essential for stealth functionality. So heat dissipation from internal control equipments should be reduced as much as possible. Control equipments mostly consist of PCBs, but it often suffers from impedance mismatching due to imprecise Dk (Dielectric Constant), which significantly increases heat dissipation. In this paper, measurement methods of Dk is investigated. Also, effects on impedance mismatch by Dk variation with operating frequency is investigated.

An Seismic Performance Study according to Reinforcement Method of Aramid Rods and SRF of Damaged RC Column (손상된 철근콘크리트 기둥의 Aramid봉과 SRF 보강공법에 따른 내진성능연구)

  • Oh, HaeCheol;Lee, Kihak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.15 no.4
    • /
    • pp.91-98
    • /
    • 2015
  • This paper has proposed a reinforcing method for damaged RC columns with SRF sheets and Aramid rods. In order to verify the effectiveness and performance, two original columns and two reinforced columns with SRF sheets and Aramid rods were developed and tested under lateral cyclic displacement and a constant axial load. The test showed that the improvement of energy dissipation capacity was increased in terms of strength and ductility. In addition, an analytical modeling of the standard specimens was proposed using Response-2000 and ZeusNL program. The results of analytical and experimental studies for two standard columns were compared in terms of loading-displacement curve and energy dissipation capacity based on the nonlinear static analysis.

Effects of Viscous Dissipation on the Thermal Instability of Plane Couette Flow Heated from Below (밑으로부터 가열되는 평면 Couette 유동에서 점성소산이 열적 불안정성에 미치는 영향)

  • Yoo, Jung Yul;Park, Young Moo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.489-498
    • /
    • 1988
  • An analysis has been given for the effect of viscous dissipation on the thermal instability of plane Couette flow between two parallel plates maintained at different constant temperatures. Under the assumption that the principle of the exchange of stabilities holds, stationary disturbance quantities in the form of longitudinal vortices are considered. The magnitudes of disturbance quantities are then represented as fast convergent power series so that the eigenvalue problem for determining the onset conditions of the thermal instability may be reduced to a simplified problem of finding the roots of a $4{\times}4$ determinant. It is shown that as the magnitude of the visucous dissipation increases the flow becomes more susceptible to instabilities, which is in very good agreement with previous results obtained in some related researches.

  • PDF

Residue Dissipation Kinetics and Safety Evaluation of Insecticides on Strawberry for the Harvest Periods in Plastic-covered Greenhouse Conditions (시설재배 딸기의 생산단계에서 살충제 잔류량에 따른 반감기 및 감소상수 산출에 의한 안전성 평가)

  • Chang, Hee-Ra;You, Jung-Sun;Ban, Sun-Woo
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.2
    • /
    • pp.122-129
    • /
    • 2020
  • BACKGROUND: Dissipation patterns of insecticides (acequinocyl, clothianidin, diflubenzuron, thiacloprid, and thiamethoxam) on strawberry grown in plastic-covered greenhouse were evaluated at 7 intervals including the preharvest interval after application. This study was performed to determine the residue concentrations, half-lives and dissipation rates in strawberry for the harvest periods. METHODS AND RESULTS: Acequinocyl, clothianidin, diflubenzuron, thiacloprid, and thiamethoxam were applied in accordance with critical good agricultural practices for strawberry. Strawberry samples were collected at 0, 1, 2, 3, 5, 7 and 10 days after application. Quantitaion was performed by HPLC/DAD and HPLC-MSMS system with C18 column. The limit of quantitation (LOQ) values varied between were 0.00025~0.05 mg/kg on strawberry. The recoveries of acequinocyl, clothianidin, diflubenzuron, thiacloprid and thiamethoxam at two concentrations ranged from 70.9~104.9% on strawberry. The half-lives of pesticide dissipation on strawberry for two fields ranged from 1.3~8.2 days. The dissipation rates were evaluated according to the statistics method with a 95% confidence. CONCLUSION: The residue levels of insecticides (acequinocyl, clothianidin, diflubenzuron, thiacloprid, and thiamethoxam) on strawberry at 0-day after application were below the specified values by Korean MRL. To estimate dissipation rate constant of pesticides on crop for harvest periods, it is important to set the pre-harvest residue limit for human health and consumer protection in Korea.

Effect of vertical reinforcement connection level on seismic behavior of precast RC shear walls: Experimental study

  • Yun-Lin Liu;Sushil Kumar;Dong-Hua Wang;Dong Guo
    • Earthquakes and Structures
    • /
    • v.26 no.6
    • /
    • pp.449-461
    • /
    • 2024
  • The vertical reinforcement connection between the precast reinforced concrete shear wall and the cast-in-place reinforced concrete member is vital to the performance of shear walls under seismic loading. This paper investigated the structural behavior of three precast reinforced concrete shear walls, with different levels of connection (i.e., full connection, partial connection, and no connection), subjected to quasi-static lateral loading. The specimens were subjected to a constant vertical load, resulting in an axial load ratio of 0.4. The crack pattern, failure modes, load-displacement relationships, ductility, and energy dissipation characteristics are presented and discussed. The resultant seismic performances of the three tested specimens were compared in terms of skeleton curve, load-bearing capacity, stiffness, ductility, energy dissipation capacity, and viscous damping. The seismic performance of the partially connected shear wall was found to be comparable to that of the fully connected shear wall, exhibiting 1.7% and 3.5% higher yield and peak load capacities, 9.2% higher deformability, and similar variation in stiffness, energy dissipation capacity and viscous damping at increasing load levels. In comparison, the seismic performance of the non-connected shear wall was inferior, exhibiting 12.8% and 16.4% lower loads at the yield and peak load stages, 3.6% lower deformability, and significantly lower energy dissipation capacity at lower displacement and lower viscous damping.

Optimum Design of Multi-Stacking Current Lead Using HTS Tapes (고온초전도 테이프를 이용한 적층형 전류 도입선의 최적설계)

  • 설승윤;김민수;나필선
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.35-39
    • /
    • 2001
  • The optimum cross-sectional area profile of gas-cooled high-temperature superconductor(HTS) current lead is analyzed to have minimum helium boil-off rate. The conventional constant area HTS lead has much higher helium consumption than the optimum HTS lead considered in this study. The optimum HTS lead has variable cross-sectional area to have constant satiety factor. An analytical formula of optimum shape of lead and temperature profile are obtained. For multi-stacking HTS current leads, the optimum tape lengths and minimum heat dissipation rate are also formulated. The developed formulations are applied to the Bi-2223 material, and the differences between constant area, constant safety-factor, and multi-stacking current leads are discussed.

  • PDF

Optimal Design of Multi-Step Current Leads Using HTS Tapes (고온초전도 테이프를 이용한 다단 전류 도입선의 최적설계)

  • 김민수;나필선;설승윤
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.84-88
    • /
    • 2001
  • The optimum cross-sectional area Profile of gas-cooled high-temperature superconductor (HTS) current lead is analyzed to have minimum helium boil-off rate. The conventional constant area HTS lead has much higher helium consumption than the optimum HTS lead considered in this study. The optimum HTS lead has variable cross-sectional area to have constant safety factor. An analytical formula of optimum shape of lead and temperature profile are obtained. For multi-step HTS current leads, the optimum tape lengths and minimum heat dissipation rate are also formulated. The developed formulations are applied to the Bi-2223 material, and the differences between constant area, constant safety-factor, and multi-step current leads are discussed.

  • PDF