Fabrication of Disposable Light Exposure Detector Kit using UV Curable Hydrogels (자외선 경화 하이드로겔을 사용한 일회용 빛 노출 검출 키트의 제조와 특성분석)

  • Kim, Young Ho;Kim, Gyu-Man;Dang, Trung Dung;Choi, Jin Ho;Kim, Hwan-Gon;Park, Sangju;Lee, Sang Hak
    • Applied Chemistry
    • /
    • v.15 no.1
    • /
    • pp.17-20
    • /
    • 2011
  • A disposable light exposure detector kit has been developed by UV curing of a hydrogel material. The devised light exposure detector kit consisted of light sensitive structures, bottom plate, character sheet and sticky back plate. A light exposure detector kit has a serial light sensitive structures that contain various light sensitive dyes such as rhodamine and fluorescein. The light sensitive structure composed of UV curable hydrogel polymer material as a supporing material and photosensitive dye in a certain concentration. The fabrication procedure of the ligh exposure detector kit is very simple and fast due to UV curing procedure of a photopolymerizable hydrogel material such as poly(ethylene glycol) methyl ether acrylate (PEGMEA) and poly(ethylene glycol) diacrylate (PEGDA) with a photosensitive dye. By the proposed fabrication method, various size and shape of a light exposure detector kit could be fabricated using a flexible elastomer mold. Due to a fast and inexpensive fabrication method, the light exposure detector kit could be use a single use for various industrial applications. According to light irradation, the light sensitive structure on a light exposure detector kit could be lose its color by decomposition of a photosensitive dye chemical in the structure. Thus the amount of the exposed light on a substrate could easily be recognised by changing color or transparency of the structure.

A Case Study of SFR Disposal Facility in Sweden to Derive the Total Disposable Amount of Radioactive Waste Containing Cellulose in Low and Intermediate Level Radioactive Waste Disposal Facility in Gyeongju (경주 중저준위방폐물 처분시설 내 셀룰로오스 함유 방폐물 처분가능 총량 도출을 위한 스웨덴 SFR 처분시설 사례 분석)

  • JaeChul Ha;MyungGoo Kang;SeHo Choi
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.501-508
    • /
    • 2023
  • There are various factors that have a negative impact on safety over a long period of time after the closure of a radioactive waste disposal facility. In particular, it is important to limit substances that accelerate radionuclide migration while inhibiting adsorption between radionuclides and the subsurface medium. Through this study, a method for deriving a quantitative criteria evaluation method is proposed for cellulose among materials that accelerate the movement of these radionuclides after closure of the disposal facility. Since Sweden's SKB is representative worldwide for preparing criteria for cellulose in disposal facilities, it analyzed Sweden's acceptance criteria method and presented a method that can be applied domestically. The decomposition characteristics of cellulose and the adsorption and dissolution characteristics of ISA among degradation products were reviewed, and quantitative analysis of cement materials that create a high pH environment favorable for cellulose decomposition was also included. In addition, the total amount of the finally disposable cellulose material can be derived by using the volume information of the waste containing the cellulose material. Through this methodology for calculating the total amount of cellulose, it is expected that subsequent studies will be conducted to secure data reflecting the environmental conditions of radioactive waste disposal facilities in Korea. In addition, it is expected to be utilized as a good method to evaluate the impact of other complexing agents other than cellulose and to suggest the amount of disposal.

The Impact of Electricity Price Change on the Income Distribution (전력요금인하(電力料金引下)가 소득분배(所得分配)에 미치는 영향(影響))

  • Song, Dae-hee
    • KDI Journal of Economic Policy
    • /
    • v.13 no.1
    • /
    • pp.135-149
    • /
    • 1991
  • The economic policy of decreasing the electricity price is widely understood to have the effect of stabilizing the general price level and improving the income distribution. However, the impact of electricity price decrease on the income distribution is not quite sure although the electricity price decrease would increase the disposable income of all households. The electricity price change would affect the income distribution through three channels. The first impact on the income distribution is made through the electricity price sructure; Korean electricity price structure is designed to subsidized the industrial sector at the cost of household consumption sector in the sense that the price per unit electricity for industrial sector is much lower than that for household consumption sector. The second impact on the income distribution is created through the disposable household income effect of the price decrease; Relative disposable income effect among households appeared higher to lower income household group and this relative disposable income effect seem to improve the income distribution although the net effect is very small. The third impact on the income distribution is formulated through the net profit effect of entreprise sector; This unearned net profit increase to the already rich industrial entrepreneurs group could create a negative income distribution effect. A simulation of 10% electricity price decrease with all the price structure given was attempted to calculate the net effect of income distribution and it was found the net income distribution effect of flat electricity price decrease to be negative contrary to the general understanding. The income distribution effect would only be one criterion among many other criteria considered in the electricity price making process. The electricity price decrease would be helpful to the price stabilization and price competitiveness of industrial sector. However, it does not improve the general income distribution status by the electricity price decrease with the price structure given.

  • PDF

Formaldehyde Monitoring of Hygiene Products in Domestic Market (국내 유통 위생용품 중 포름알데히드 잔류량 모니터링)

  • Na, Young-Ran;Kwon, Hyeon-Jeong;Cho, Hyun-Nho;Kim, Hyeon-Jin;Park, Yon-Koung;Park, Sung-Ah;Lee, Seong-Ju;Kang, Jung-Mi
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.3
    • /
    • pp.225-233
    • /
    • 2020
  • By the standards and specifications for hygiene products, three test methods for formaldehyde are specified for each item type of hygiene product. After derivatization using acetylacetone and 2,4-dinitrophenylhydrazine (2,4-DNPH), formaldehyde is analyzed by spectrophotometer and high-performance liquid chromatography (HPLC). Validation of the three test methods was performed on tissue, diaper lining and waterproof layer, and panty liner products. The results of linearity (R2), limit of detection (LOD), limit of quantification (LOQ), recovery rate (%) and reproducibility (%), showed that all three methods are suitable for analyzing formaldehyde in hygiene products. After derivatization with 2,4-DNPH and cetylacetone, formaldehyde was analyzed at 0, 3, 6, 9, 24 and 48 hours by HPLC. Formaldehyde derivatized with 2,4-DNPH showed no statistically significant change in formaldehyde peak area over time (P>0.05). But, acetylacetone-derivatizated formaldehyde showed a negative correlation coefficient (r) over time (P<0.01). We investigated the residual amounts of formaldehyde in 205 hygiene products distributed in Busan. Among 74 disposable diaper products tested, 73 had low concentrations of formaldehyde (0.13-29.87 mg/kg). Moreover, formaldehyde was not detected in any of 78 tissue, 27 disposable paper towel, 12 disposable dishcloth, 7 paper cup, one brand of paper straw and 6 disposable napkin products.

Urine Collection from Disposable Diapers in Infants and Young Children (유소아에서 일회용 기저귀를 이용한 소변 채취 방법)

  • Kim Mi Jeong;Kim Ji Hae;Yim Hyung Eun;Kang Hee;Eun Baik Lin;Yoo Kee Hwan;Hong Young Sook;Lee Joo Won;Kwon Junga
    • Childhood Kidney Diseases
    • /
    • v.9 no.2
    • /
    • pp.128-136
    • /
    • 2005
  • Purpose : Urine collection using a sterile adhesive bag for urinalysis has been used commonly in infants and young children. However, this method has had some drawbacks. So, this study was performed to evaluate the usage of disposable diapers as a substitute for the routine urine collection method. Methods : 60 mL of self voided fresh urine was collected from 99 patients. Half of the urine was poured on the disposable diapers which did not contain absorbent gel beads. After 1 hr, we obtained the urine samples(extracted urine) by compressing the wet diapers using a 50 ml syringe. Routine, microscopic and biochemical analyses were performed on the other half of fresh urine and extracted urine. Then we compared each result by correlative analysis. Results : 198 samples from 99 patients were evaluated. The results of routine urinalysis except WBC and biochemical urinalysis showed a significant correlation between the two groups(P<0.05). The relative coefficients of urine SG, pH, glucose, protein, blood and leukocytes between the two groups were 0.964, 0.938, 0.977, 0.956, 0.931 and 0.738, respectively. Those of urinary sodium, potassium, chloride and creatinine were 0.997, 0.998, 0.995 and 0.998, respectively Microscopic examinations showed lower relative coefficients than the other results, 0.740 for RBC and 0.602 for WBC, but these were still significant(P<0.05). Conclusion : The results of the urine analysis with extracted urine from diapers correlates well with that of fresh urine. This new method is very helpful and can be used as an alternative of urine collection, especially for infants and young children. (J Korean Soc Pediatr Nephrol 2005;9:128-136)

  • PDF

Microfluidic Components and Bio-reactors for Miniaturized Bio-chip Applications

  • Euisik Yoon;Yun, Kwang-Seok
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.86-92
    • /
    • 2004
  • In this paper miniaturized disposable micro/nanofluidic components applicable to bio chip, chemical analyzer and biomedical monitoring system, such as blood analysis, micro dosing system and cell experiment, etc are reported. This system includes various microfluidic components including a micropump, micromixer, DNA purification chip and single-cell assay chip. For low voltage and low power operation, a surface tension-driven micropump is presented, as well as a micromixer, which was implemented using MEMS technology, for efficient liquid mixing is also introduced. As bio-reactors, DNA purification and single-cell assay devices, for the extraction of pure DNA from liquid mixture or blood and for cellular engineering or high-throughput screening, respectively, are presented.

Development of a Test Strip Reader for a Lateral Flow Membrane-based Immunochromatographic Assay

  • Park, Je-Kyun;Kim, Suhyeon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.127-131
    • /
    • 2004
  • A low-cost, simple strip reader system using a linear movement mechanism of CD-ROM deck has been developed to characterize a lateral flow membrane-based immunochromatographic assay. The test strip reader was assembled by a CD-ROM deck and home-made optical head especially designed for immunoassays. The optical head for detecting reflected light from the test strip surface consists of green light-emitting diode, large area silicon photodiode, and anodized aluminum mounting block providing a slit structure for cutting light from the LED. The stepping motor of the deck was operated in the full step mode, whose distance of each reading point is about 0.15mm. The performance of the strip reader was tested by analysis of HBV(hepatitis B virus) antigen test kit. This strip reader can be useful for inexpensive, disposable, and membrane-based assays that provide visual evidence of the presence of an analyte in a liquid sample.

MULTI-SHAPE ERYTHROCYTE IMAGING AND THEIR DEFORMABILITY ANALYSIS IN A MICROFLUIDIC ENVIRONMENT

  • Jayavanth, Sanjay;Pak, Bock-Choon
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2791-2796
    • /
    • 2007
  • In their long journey through the cardiovascular circuit, erythrocytes are coerced to shape transform and assume different shapes on account of varying flow conditions in different blood vessels. The present work was aimed to visualize these erythrocyte shape transformations by an invitro microcirculatory model, and assess multi-shape erythrocyte deformability. The model uses an in-house fabricated, inexpensive disposable micro flow channel to mimic certain invivo conditions and a fast frame video microscopic system for imaging the shape changes in erythrocytes. Results show the multi-shape transformation of erythrocyte christened as discoidal shape, the asymmetrically deformed 'hat' and 'bullet-like' shapes, and the axially deformed 'slipper' and 'spindle-like' shapes. Specific erythrocyte showed the shape transition and transformation while passing through the observed window. The obtained erythrocyte shapes very analyzed for deformability index using image processing techniques that varied significantly (p <0.001) for different shapes as compared with the resting shape.

  • PDF

A Photosensitive Glass Chip for DNA Purification of Nucleic Acid Probe Assay

  • Kim, Joon-Ho;Kim, Byung-Gyun;Yoon, Jun-Bo;Euisik Yoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.4
    • /
    • pp.232-238
    • /
    • 2001
  • A new DNA purification chip is proposed and fabricated for the sample preparation of Nucleic Acid (NA) probe assay. The proposed DNA purification chip is fabricated using photosensitive glass substrate and polydimethylsiloxane (PDMS) cover fixture. We have successfully captured and eluted the DNA using the fabricated photosensitive glass chip. The fabricated DNA purification chip showed a binding capacity of $15ng/\textrm{cm}^2$and a minimum extractable input concentration of $100copies/200\muL$. The proposed DNA purification chip can be applied for low-cost, disposable sample preparation of NA probe assays.

  • PDF

The Appropriatness of Government Support of Shipping Industry ; A General Equilibrium Approach (해운산업에 대한 정부지원의 타당성 검토)

  • 정봉민
    • Journal of Korean Society of Transportation
    • /
    • v.8 no.2
    • /
    • pp.27-41
    • /
    • 1990
  • In this study the economic impacts of government support of shipping industry in the labor rich country are appraised in a general equilibrium model. Shipping industry subsidies (which are supposed to be supplied by lump-sum tax) will decrease disposable income by shifting productive resources from traded goods to the comparatively disadvantageous transport sector, and at the same time reduce the implicit tariff effect by lowering transport costs. The net effect of shipping industry subsidies is to increase social welfare because the latter positive effect of shipping industry subsidies is to increase social welfare because the latter positive effect dominates the former negative effect. Such an increase in social welfare can never be expected from competitive traded goods industry subsidies in the case of which social welfare will actually decrease because of inefficient resource allocation resulting from the subsidies. In addition it is worth noting that the subsidies on the most capital intensive shipping industry will rectify unevenness in income distribution by raising relative price of labor contrary to subsidies on capital intensive traded goods.