• 제목/요약/키워드: discharge pressure

검색결과 1,470건 처리시간 0.067초

인젝터 압력이 단공노즐 감압비등 분무에 미치는 영향 (Effect of Injection Pressure on the Flash Boiling Spray from Simple Orifice Nozzle)

  • 이현창;차현우;강동현
    • 한국분무공학회지
    • /
    • 제27권1호
    • /
    • pp.42-49
    • /
    • 2022
  • Flash boiling occurs in a couple of modern engineering systems and understanding its mechanism is important. In this experimental study, discharge coefficient of flash boiling spray from simple orifice nozzle was measured, and backlight imaging was acquired at injection pressure to 6.0 bar and temperature to 163℃ for the purpose. Pressurized water by pump was used for working fluid and was heated by electric heater and ejected through simple orifice nozzle diameter of 0.5 mm. High speed camera with long distance microscope was used for backlight imaging in two FoV having magnification of 3.3 and 0.64. The decrease of discharge coefficient according to degree of superheating and evolution of flash boiling spray imaged at various pressure and temperature were explained by the pressure field inside the injector.

최적설계법을 응용한 가스계 소화설비의 약제방출량 산출 (Application of Optimal Design Method to Agent Discharge Flow Calculation of Gaseous Fire Extinguishing Systems)

  • 이동명
    • 한국화재소방학회논문지
    • /
    • 제29권5호
    • /
    • pp.51-56
    • /
    • 2015
  • 본 연구에서는 설계프로그램의 공학적 분석의 수단 또는 가치공학 측면에서 원가절감 등의 목적으로 최적설계 이론과 공학적 이론을 접목시킨 최적설계법을 가스계 소화설비 중 청정소화약제 소화설비의 약제방출량 산출에 응용하였다. 청정소화약제 소화설비의 설계이론과 최적설계 이론을 바탕으로 약제방출량을 최적화시킬 수 있는 최적설계인자를 도출하였고, 이를 설계인자로 구축된 소화설비의 소화성능시험으로 최적설계법의 적합성 여부를 검증함으로써 다른 소화설비에도 최적설계법을 접목할 수 있는 기틀을 마련하였다. 방출헤드의 약제방출량 최적화는 방출헤드 및 배관의 내경, 약제도달시간, 유량과 압력변화 등의 소화약제 유동특성에 대한 제한조건에 의해 결정됨을 확인하였고, 방출헤드의 방출압력과 약제도달시간의 편차는 배관의 압력변화만큼 발생되고 상관관계가 있음을 알 수 있었다.

Study on Flow Analysis of Three-Dimensional Screw Propeller With Respect to Rotational Speed Variable

  • Moon, Byung-Young;Sun, Min-Young;Lee, Ki-Yeol
    • 한국해양공학회지
    • /
    • 제28권6호
    • /
    • pp.500-507
    • /
    • 2014
  • This study aimed at conducting a flow analysis of the pressure distribution, discharge flow rate, and consequent thrust force according to the rotational speed of a three-dimensional screw propeller, and then investigating the effect of the rotational speed on the characteristics of the screw propeller by varying the relevant speed (3200, 2400, 1600, 800 rpm). In particular, the computational domain was considered by the analysis in the blades and outlet chamber, using boundary conditions. The difference between the minimum and maximum pressures was 5.5 MPa under the given conditions. The discharge flow rate at this pressure difference was on the level of 1956.67 kg/s, as a thrust force of 47083.7 T(N) was obtained. This study showed that the discharge flow rate linearly increased with the rotational speed, proportional to the RPM, while the thrust force was gradually and steadily increased with the relevant speed. In addition, it was proved that the occurrence of cavitation under the given conditions was closely related to the decrease in the durability of the screw propeller because the thrust force depends on the speed.

옥내소화전설비의 방수압 측정 개선에 관한 연구 (A Study on Improvement of Discharge Pressure Measurement of Indoor Fire Hydrant System)

  • 민세홍;정상호
    • 한국화재소방학회논문지
    • /
    • 제26권3호
    • /
    • pp.67-72
    • /
    • 2012
  • 건축물 실내에서의 화재발생 시 초기 소화설비로 적용하고 있는 옥내소화전설비와 스프링클러설비는 초기화재 진압용으로 큰 역할을 담당하고 있다. 최근 건축물의 지붕형태는 차별화된 지역문화와 디자인이 접목된 다양한 형태의 건축물이 건립되고 있다. 차별화된 지붕형태, 즉 일부 건축물의 지붕형태가 경사(박공)형태로 계획 건립되고, 또한 공중정원을 활용한 조망계획을 하다 보니 옥내소화전설비의 방수압력을 측정하는데 있어 옥상공간은 제한적이고, 너무 협소하여 옥내소화전 소방호스를 전개(최대 5개)하여 방수압력 측정하는데 있어 문제점이 도출되고 있다. 이러한 문제점을 보완하여 옥내소화전설비의 효율적인 관리와 화재 시 초동조치가 가능하도록 개선방안을 연구하고자 한다.

Simulation of Low Temperature Plasmas for an Ultra Violet Light Source using Coplanar Micro Dielectric Barrier Discharges

  • Bae, Hyowon;Lee, Ho-Jun;Lee, Hae June
    • Applied Science and Convergence Technology
    • /
    • 제25권6호
    • /
    • pp.138-144
    • /
    • 2016
  • The discharge characteristics of pulse-driven coplanar micro barrier discharges for an ultraviolet (UV) light source using Ne-Xe mixture have been investigated using a two-dimensional fluid simulation at near-atmospheric pressure. The densities of electrons, the radiative excited states, the metastable excited states, and the power loss are investigated with the variations of gas pressure and the gap distance. With a fixed gap distance, the number of the radiative states $Xe^*(^3P_1)$ increases with the increasing driving voltage, but this number shows weak dependency on the gas when that pressure is over 400 Torr. However, the number of the radiative states increases with the increase of the gap distance at a fixed voltage, while the power loss decreases. Therefore, a long gap discharge has higher efficiency for UV generation than does a short gap discharge. A slight change in the electrode tilt angle enhances the number of radiative species 2 or 3 times with the same operation conditions. Therefore, the intensity and efficiency of the UV light source can be controlled independently by changing the gap distance and the electrode structure.

원추형 오리피스의 유출계수와 캐비테이션에 관한 실험적 연구 (Experimental study on the discharge coefficients and cavitation of conical orifices)

  • 김병찬;윤병옥;박복춘;조남오;지대성;정백순;박경암
    • 대한기계학회논문집B
    • /
    • 제21권10호
    • /
    • pp.1371-1379
    • /
    • 1997
  • The high pressure drop is frequently required in the by-pass line of the pump or of the heat exchanger in power plants. However, cavitation produced by a high pressure drop could damage the pipe and pump blades. Conical orifices are adopted to reduce cavitation due to high pressure drop. The discharge coefficients of conical orifice plates were measured by weighing method in the standard water flow system. The discharge coefficients were larger when the ratios of thickness of orifice edge to throat diameter were larger. The noise generated from a conical orifice due to cavitation was measured with a sound level meter and a hydrophone. With increasing the bore diameter of the orifice, the sound pressure level or the noise level due to cavitation became higher. The noise level was suddenly increased at the inception of cavitation.

대기압 RF DBD 방전으로 개질된 폴리이미드의 표면특성 (Surface Properties of Polyimide Modified with He/O2/NF3 Atmospheric Pressure RF Dielectric Barrier Discharge)

  • 이수빈;김윤기;김정순
    • 한국재료학회지
    • /
    • 제16권9호
    • /
    • pp.543-549
    • /
    • 2006
  • Polyimides (PI) are treated with $He/O_2$ and $He/O_2/NF_3$ atmospheric pressure rf dielectric barrier discharge in order to investigate the roles of $NF_3$ that is one of the PI etching gases. Surface changes are analyzed by x-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and contact angle measurement. The surface roughness of PI and the ratio of C=O, which is hydrophilic functional group, is more increased by $He/O_2/NF_3$ discharge than by $He/O_2$ discharge. The C=O species on the PI surface is increased up to 30 percent with rf power. The surface roughness of PI is increased from 0.4 to 11 nm with rf power. The water drop contact angles on PI, however, are reduced from $65^{\circ}\;to\;9^{\circ}$ by plasma treatment independently of $NF_3$.

플라즈마 디스플레이 패널에서 압력에 3차원 시간 분해 측정 (The Measurement of Three-Dimensional Temporal Behavior According to the Pressure in the Plasma Display Panel)

  • 최훈영;이석현;이승걸
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권10호
    • /
    • pp.476-480
    • /
    • 2003
  • In this paper, we have performed 3-dimensional time-resolving measurement of the Ne light emitted from the cell of plasma display panel(PDP) as a function of the pressure using the scanned point detecting system. From the temporal behavior results, we could analyze the discharge behavior of panel with Ne-Xe(4%) mixing gas and 300 torr, 400 torr and 500 torr pressure. At the top view of panel, the discharge of 300 torr panel starts at the 634 ns and ends at the 722 ns. The emission duration time is about 90 ns. The discharge of 400 torr panel starts at the 682 ns and ends at the 786 ns. the emission duration time is about 100 ns. Also, the discharge of 500 torr panel starts at the 770 ns and ends at the 826 ns. the emission duration time is about 56 ns. The discharge moves from inner edge of cathode electrode to outer cathode electrode forming arc type. In the side view of 300 torr, 400 torr and 500 torr an emission shows that the light is detected up to 180${\mu}{\textrm}{m}$, 150${\mu}{\textrm}{m}$ and 70${\mu}{\textrm}{m}$ height of barrier rib and the emission distribution of the 300 torr is wider than 400 torr, 500 torr.

연직배수재의 통수능력 저감요인 분석을 위한 실험적 연구 (Experimental Study on the Reduction of the Discharge Capacity of Vertical Drains)

  • 김찬기;채영수;이강일
    • 한국지반신소재학회논문집
    • /
    • 제4권3호
    • /
    • pp.3-10
    • /
    • 2005
  • 본 연구는 연직 배수재의 통수능력 저감 요인인 측방토압, 동수경사, 배수재의 변형에 의한 통수능력의 저감을 밝히기 위하여 현장조건에 가장 부합되는 고무 멤부레인 안에 하모니카형, 성곽형, 파이버형 드레인을 설치한 후 드레인 주변에 슬러리 상태의 점토를 넣고 통수능 특성에 관한 실험을 실시하였다. 그 결과 배수재의 종류에 따른 통수능력은 하모니카형, 성곽형, 파이버형 순으로 통수능력이 컸으며, 또한 측압 보다 동수경사에 대한 통수능력 감소가 높게 나타났다.

  • PDF