• Title/Summary/Keyword: discharge flow rate

Search Result 758, Processing Time 0.027 seconds

A Study on the Thermal Characteristics of Cooling System for Securing Battery Stability in Electric Vehicle (전기자동차 배터리 안정성 확보를 위한 냉각장치 열특성 연구)

  • Otgonpurev, Tuul;Ko, Gwang Soo;Park, Youn Cheol
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.2
    • /
    • pp.7-12
    • /
    • 2020
  • The battery of an electric vehicle is a key part of the energy supply to operate the vehicles. There are many factors affecting battery life such as charging method, discharge rate, and ambient temperature those are requires systematic monitoring and management. To solve the issues like environmental problems and fuel consumption reduction the battery needs more performance improvement. In this study, it was analyzed the thermal characteristics and securing battery stability for electric vehicle battery cooling system. The simulation test was operated using GT-suite software with several conditions like cooling capacity 1, 2 and 4 kW, cooling flow rate 5, 10, 20 and 30 LPM, and battery initial temperatures 40, 35, and 30℃ at the temperature of ambient 25℃. The results shown that the case of cooling flow rate at 20 LPM was most efficient among all above conditions.

A Development of Washoff Model for Suspended Solids in Urban Areas (도시유역의 부유고형물 유출평가를 위한 쓸림모형 개발)

  • Joo, Jingul;Jung, Donghwi;Kim, Joonghoon;Park, Moojong
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.789-795
    • /
    • 2010
  • Suspended Solid (SS) is one of the main pollutants and discharges with attached other pollutants such as heavy metal and toxic substance. It is very important to estimate and forecast the release characteristics of SS for water quality improvement. The current studies assumed that SS release rate is proportional to the rain intensity and suggested exponential washoff models. These models related to the shear force of flow. In this study, a new washoff model is suggested based on relation with SS release rate and mean flow rate of the basin surface which is closely related to the shear force. The proposed model is applied to the Goonja drainage district in Seoul, Korea. The new washoff model simulates the SS discharge more accurately in the various rainfall types. The model can be widely applied to the real problems such as the management of non-point source pollutant and the design of treatment facilities.

Comparison between a 3 Dimensional Turbulent Numerical Model and Hydraulic Experiment Model for the flow phenomenon around a Lock Gate (배수갑문 주위의 흐름현상에 대한 3차원 난류 수치모형과 수리모형실험의 비교)

  • Lee, Sang-Hwa;Jang, Eun-Cheul;Ha, Jae-Yul
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.2
    • /
    • pp.162-169
    • /
    • 2007
  • This study is focused on the comparison of a 3 dimensional numerical and hydraulic model experiment for the flow phenomenon when a lock gate is opened. The lock gate is designed to discharge the flood flow rate at $218m^3/s$ of Solicheon at the Kun Jang national industry complex. The three dimensional ${\kappa}-{\epsilon}$ turbulent model of ANSYS CFX-10 of the computational fluid dynamics(CFD) program was used. The characteristics of CFX-10 are able to be simulated effectively for turbulent flow, especially the flow separation of the boundary layer of the two phase interface of air and water. The velocity and the flow pattern of the numerical model was showed to be similar to the results of the hydraulic model experiment.

A Decision-Supporting Model for Rehabilitation of Old Water Distribution Systems

  • Kim, Joong-Hoon;Geem, Zong-Woo;Lee, Hyun-dong;Kim, Seong-Han
    • Korean Journal of Hydrosciences
    • /
    • v.8
    • /
    • pp.31-40
    • /
    • 1997
  • Flow carrying capacity of water distribution systems is getting reduced by deterioration of pipes in the systems. The objective of this paper is to present a managerial decision-making model for the rehabilitation of water distribution systems with a mininum cost. The decisions made by the model also satisfy the requirements for discharge and pressure at demanding nodes in the systems. Replacement cost, pipe break repair cost, and pumping cost are considered in the economic evaluation of the decision along with the break rate and the interest rate to determine the optimal replacement time for each pipe. Then, the hydraulic integrity of the water distribution system is checked for the decision by a pipe network simulator, KYPIPE, if discharge and pressure requirements are satisfied. In case the system does not satisfy the hydraulic requirements, the decision made for the optimal replacement time is revised until the requirments are satisfied. The model is well applied to an existing water distribution system, the Seoul Metropolitan Water Supply System (1st Phase). The results show that the decisions for the replacement time determined by the economic analysis are accepted as optimal and hydraulic integrity of the system is in good condition.

  • PDF

Development of a Milk Filtering System for Decreasing Somatic Cell Count (체세포수 감소를 위한 우유여과시스템 개발)

  • Chang, Jin-Tack;Kim, Wan-Young;Yeo, Joon-Mo;Kang, In-Chul;Lee, Seung-Kee
    • Journal of Animal Environmental Science
    • /
    • v.20 no.1
    • /
    • pp.15-20
    • /
    • 2014
  • The present study was conducted to develop a milk filtering system for decreasing somatic cell count (SCC) in bulk tank milk. The pore sizes of the filter were 0.1, 0.3, 0.4, 0.5 and $0.8{\mu}m$. The rate of SCC reduction of $1^{st}$ grade milk on $0.1{\mu}m$ filter was 76% and significantly higher than other treatments. The rates of SCC reduction for 0.3, 0.4, 0.5 and $0.8{\mu}m$ were 35, 32, 18 and 6.4%, respectively. The effects of the milk filtering system on bacterial count and milk fat content were minimal. The milk flow rates per minute between the filter sizes were similar. But discharge pressures were increased as the pore size of the filter decreased. In conclusion, Considering the rate of SCC reduction, discharge pressure and cost, $0.4{\mu}m$ filter could be recommended.

The control system of sludge amount inspection and discharge materials of outlet water and affiliated water-purification tank (오수/합병정화조의 배출물 제어시스템 연구)

  • 박주식;김건호;오지영;임총규;강경식
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2001.11a
    • /
    • pp.193-202
    • /
    • 2001
  • The individual rotten water purification tank recently discharges wastewater and sewage through the outlet without purification ability. The outlet water and affiliated water purification tank with microorganism cultivator tank cultivates microorganism and then drops the value BOD, COD of sewage and discharges the quality of water into the outlet. The blower and water pump operating continuously prompts the waste of energy and deterioration of equipment. Each room of deposition tank, foaming tank, microorganism cultivator tank is equipment with the sludge detection senses so it can detect the density of each room. The power-drive plant of the blower and water pump which ate the system cultivating the microorganism must be made as fuzzy controlization (If the sludge amount of each room become higher, the rate of operation of blower and water pump must heighten, on the contrary, in case of row sludge amount, the total handling amount and microorganism handling amount of each room of control. Tank reducing the rate of operation must be DB. At present, the blower amount in proportion to the sludge and oxygen demanding amount has to control. Each mom must be checked outlet level of the outlet, also each room must flow backward discharge materials, and must operate feed-back control until we want to be come as a below value of BOD/COD(10PPM ; KS).

  • PDF

The Development using Fuzzy Control of sludge amount inspection and discharge materials of outlet water and affiliated water-purification tank (퍼지제어를 통한 오수-합병정화조의 오니 측정 및 제어시스템에 관한 연구)

  • 박주식;박윤규;강경식
    • Journal of the Korea Safety Management & Science
    • /
    • v.3 no.4
    • /
    • pp.53-63
    • /
    • 2001
  • The individual rotten water purification tank recently discharges wastewater and sewage through the outlet without purification ability. The outlet water and affiliated water purification tank with microorganism cultivator tank cultivates microorganism and then drops the value BOD, COD of sewage and discharges the quality of water into the outlet. The blower and water pump operating continuously prompts the waste of energy and deterioration of equipment. Each room of deposition tank, foaming tank, microorganism cultivator tank is equipment with the sludge detection senses so it can detect the density of each room. The power-drive plant of the blower and water pump which are the system cultivating the microorganism must be made as fuzzy controlization (If the sludge amount of each room become higher, the rate of operation of blower and water pump must heighten, on the contrary, in case of row sludge amount, the total handling amount and microorganism handling amount of each room of control. Tank reducing the rate of operation must be DB. At present, the blower amount in proportion to the sludge and oxyzen demanding amount has to control. Each room mus be checked outlet level of the outlet, also each room must flow backward discharge materials, and must operate feed-back control until we want to be come as a below value of BOD/COD(10PPM ; KS).

  • PDF

Performance evaluation of nitrate removal in high TDS wet scrubber wastewater by ion exchange resin with dissolved air flotation (DAF) process

  • Kim, Bongchul;Yeo, Inseol;Park, Chan-gyu
    • Membrane and Water Treatment
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2022
  • The regulations of the International Maritime Organization (IMO) have been steadily strengthened in ship emissions. Accordingly, there is a growing need for development of related technologies for the removal of contaminants that may occur during the treatment of SOx and NOx using a wet scrubber. However, this system also leads to wastewater production when the exhaust gas is scrubbed. In this research, we evaluated the performance of an ion selective resin process in accordance with scrubber wastewater discharge regulations, specifically nitrate discharge, by the IMO. Accelerated real and synthetic wastewater of wet scrubbers, contained high amounts of TDS with high nitrate, is used as feed water in lab scale systems. Furthermore, a pilot scale dissolved air flotation (DAF) using microbubble generator with ion exchange resin process was combined and developed in order to apply for the treatment of wet scrubber wastewater. The results of the present study revealed that operating conditions, such as resin property, bed volume (BV), and inlet wastewater flow rate, significantly affect the removal performance. Finally, through a pilot test, DAF with ion exchange resin process showed a noticeable improvement of the nitrate removal rate compared to the single DAF process.

Regional estimation of baseflow index in Korea and analysis of baseflow effects according to urbanization (국내 하천 기저유출지표 산정 및 도시화에 따른 기저유출 영향 분석)

  • Kang, Hyeongsik;Hyun, Yun-Jung;Jun, Sang-Mook
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.2
    • /
    • pp.97-105
    • /
    • 2019
  • In this study, the baseflow indices in Nakdong river watershed and the whole country's river were calculated by using SWAT model and PART method. The annual averaged baseflow in the Nakdong river watershed was estimated at 40% - 44% of the total discharge rate, and it is found to be higher than 90% during the winter months of December and January. An analysis of the baseflow index from 317 gauge stations across the country revealed that the contribution of baseflow to the nation's stream flow rate stood at an annual average of 40%, ranging from less than 20% to over 80% by region. Also, the impact of the decreasing baseflow due to land use changes in 1975 and 2000 was analyzed in Keumhogang river watershed under the same weather conditions. The results revealed that the number of days under the standard instream flow increased by 19-24 days as a result of the increase in the urbanization rate.

Atomization Characteristics of Effervescent Twin-fluid Nozzle with Different Nozzle Shapes (노즐 형상에 따른 Effervescent 이유체 노즐의 분무특성)

  • Lee, Sang Ji;Hong, Jung Goo
    • Journal of ILASS-Korea
    • /
    • v.22 no.3
    • /
    • pp.146-152
    • /
    • 2017
  • An experimental study was carried out to investigate the spray characteristics of non-circular effervescent twin-fluid nozzles. For this purpose, two types of non-circular nozzles (E1, E2) and circular nozzle (C) were used. Three types of aerorators with hole diameters of 1.2, 1.7 and 2.1 mm were used. Each aerorator has a total of 12 holes. It is defined by area ratio which is ratio of exit orifice area and aerator hole area. Experiments were carried out by controlling the amount of air flowing after fixing the flow rate of the liquid, and the nozzle internal pressure and SMD were measured, and the jet image was taken from the nozzles. The discharge coefficients of the three kinds of nozzles were compared with the used in plain orifice's equation and the Jedelsky's equation, and the Jedelsky's equation was found to be about 3 times larger. In addition, empirical formula based on ALR, which is the largest variable in Jedelsky's equation, was derived. The droplet sizes(SMD) were found to be smaller in the non-circular shape than in the circular shape, which is concluded to be caused by the difference of the discharge coefficients.