• Title/Summary/Keyword: discharge currents

Search Result 148, Processing Time 0.024 seconds

Study on Noise Reduction of Plasma Display Panel (플라즈마 디스플레이의 소음 저감 연구)

  • Park, Dae-Kyong;Kweon, Hae-Sub;Jang, Dong-Seob
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.693-698
    • /
    • 2002
  • For the evaluation of the plasma display panel (PDP)'s noise, vibration and sound characteristics of fanless PDP are measured and investigated. PDP is a type of two-electrode vacuum tube which operates on the same principle as a household fluorescent light. An inert gas such as argon or neon is injected between two glass plates on which transparent electrodes have been formed, and the glass is illuminated by generating discharge. For this discharge, both high voltage and currents are needed and cause an acoustic noise. We investigated the noise characteristics connected with both a electromagnetic elements from SMPS to panel through X, Y and logic board, and a mechanical elements form panel to case through transfer path which related with vibration and heat. To reduce the noise of PDP, a discharge pulse memory design related with both higher brightness and lower power consumption is important and mechanical characteristics connected with dissipation process of both heat and vibration generated by panel discharge must be investigated.

  • PDF

Analysis of soil discharge characteristics in sand with water content (수분 함유량에 따른 모래의 지중방전 특성 분석)

  • Lee, Bok-Hee;kim, Hoe-Gu;Park, Geon-Hun;Lee, Kyu-Sun;Ahn, Chang-Hwan
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.436-439
    • /
    • 2008
  • It has been known that the value of soil resistance drops when a high impulse curennt is injected into a grounding electrode. In this paper, impulse generator is used to investigate the dry soil and wet soil characteristics in cylinderical test cell. The impulse resistances and breakdown characteristics were discussed based on its voltage and current traces. As a result, sand resistances are decreased with increasing the applied currents. It was thought that a decrease in resistance of dry sand with increasing current is due to both thermal and ionization processes. On the other hand, in case there is no water presence in the soil, the reduction in resistance as the currents are of dry sand increased is mainly due to the ionization process.

  • PDF

A Study on the Selection of Lightning Arrester for DC Electric Traction Vehicles (전기철도용 피뢰기 선정에 관한 연구)

  • Kil, G.S.;Song, J.Y.;Kim, I.L.;Moon, S.B.;Han, J.S.
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.581-586
    • /
    • 2006
  • Selection and application recommendations of lightning arresters for DC electric traction vehicles are presented. To decide arrester specification such as continuous operating voltage(COV, $U_c$), rated voltage($U_R$), and nominal discharge current($I_n$), variations of system voltage and surge currents flowing arresters were analyzed in running-service of traction vehicles. System voltages increased up to 1,800V during anti-breaking. Surge currents recorded 3 times per running-service-route and their magnitudes were ranges of $150A{\sim}2kA$. From the field measurement and consideration of EN50163, COV, $U_c$, and $U_R$ for the $1,500V_{DC}$ traction vehicles were proposed.

  • PDF

Design of Control a Algorithm for Arc Fault Current without Current Sensor (센서없는 아크고장전류 제어 알고리즘 설계)

  • Ban, Gi-Jong;Kim, Lark-Kyo
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.6
    • /
    • pp.255-260
    • /
    • 2006
  • Arc Fault Current is an which occurrs in two opposite electrode. In this paper, arc current control algorithm is designed for the interruption of arc fault current which is occurred in the low voltage network. This arc is one of the main causes of electric fire. General arc current sensor has troubles for detecting arc currents, thus we would like to propose the arc current detection method without current sensor. In this parer, arc discharge currents within power lines are being detected through the arc current control algorithm.

Characteistics of Charge Traps and Poling Behavior of Poly (Vinylidene Fluoride)

  • Seo Jeong Won;Ryoo Kun Sang;Lee Hoo Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.6 no.4
    • /
    • pp.218-221
    • /
    • 1985
  • Transient charging and discharging currents as well as space charge limited currents have been measured in biaxially stretched poly(vinylidene fluoride) film under various poling fields and temperatures. At low temperatures and short poling times, the I-V characteristics showed shallow trap behavior. When the current values extrapolated to the infinite time, the I-V characteristics indicate that the distribution of the trap energy levels is uniform or very broad. The abnormal suppression of current at higher poling voltages and the high discharge rate observed also in the same voltage range are attributed to the morphological changes due to dipole reorientation.

Current structures and Diffusion characteristics in Youngil Bay (영일만의 해수유동 구조 및 확산특성)

  • 이종섭;김차겸
    • 한국해양학회지
    • /
    • v.30 no.5
    • /
    • pp.467-479
    • /
    • 1995
  • To investigate the current structures and diffusion characteristics in Youngil Bay, a systematic field observations of current velocity, drogue tracking, dye diffusion experiment and aerial photographing were performed. The flow patterns in the surface layer of the bay depend more strongly on the wind and ocean current than the tidal current, and the patterns in the middle are predominated by the ocean current. The residual currents in the surface generally flow toward the inner bay through the western and central areas of the bay, and then the currents go toward the ocean along the eastern shore of the bay with anti-clock-wise circulation. The residual currents in the surface of the eastern cease are not nearly influenced by the wind, and the currents always move northward to northeastward. However, the currents in the western shore depend strongly on the wind and the outflow of the Huntsman River, that is, the residual currents go northward to northeastward when the southerly to westerly winds blow or a large amount of flow from the river discharge. The residual currents in the middle layer flow toward the inner bay along the western shore of the bay, and the incomed currents go out to the ocean along the eastern shore with anticlockwise circulation. The diffusion of dye patch by the instantaneous point source shows a similar pattern to the drogue trajectory, and the apparent diffusion coefficients of the dye patch by Fick's theory is 1.14${\times}$10$^4$ cm$^2$/s. The behavior of the river discharges in flood shows a band type's effluent pattern toward the outer bay along the western coast.

  • PDF

A Study on the Algorithm of Battery SOH Estimation for Battery Management System(BMS) (배터리관리시스템(BMS)을 이용한 배터리 잔존수명(SOH) 추정 알고리즘에 관한 연구)

  • Seo, Cheol-Sik;Moon, Jong-Hyun;Park, Jae-Wook;Kim, Geum-Soo;Kim, Dong-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.317-320
    • /
    • 2008
  • This paper presents the battery management system(BMS) for the optimum conditions of the lead-Acid battery in UPS. The proposed system controls the over and under currents of battery for protecting and it was applied algorithm for optimum conditions to estimate the State Of Charge(SOC) and State Of Health(SOH) in charge or discharge mode. It approved the performance and the algorithm for the estimation of SOH, through the experiments which using the charge and discharge tester and the field tests.

  • PDF

A Study on the Battery Management System for the optimum conditions of the battery in UPS (UPS용 배터리 최적화를 위한 배터리관리시스템에 관한 연구)

  • Moon, Jong-Hyun;Seo, Cheol-Sik;Park, Jae-Wook;Kim, Geum-Soo;Kim, Dong-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.321-324
    • /
    • 2008
  • This paper presents the battery management system(BMS) for the optimum conditions of the lead-Acid battery in UPS. The proposed system controls the over and under currents of battery for protecting and it was applied algorithm for optimum conditions to estimate the State Of Charge(SOC) in charge or discharge mode. It approved the performance and the algorithm for the estimation of SOC, through the experiments which using the charge and discharge tester and the field tests.

  • PDF

A study on the analysis of carrier properties and trap energy depth in the low-density polythylene electrets (저밀도 폴리에틸렌 일렉트렉트에 있어서 케리어의 성질과 Trap 깊이 해석에 대한 연구)

  • 이준웅
    • 전기의세계
    • /
    • v.29 no.8
    • /
    • pp.511-518
    • /
    • 1980
  • The thermostimulated discharge currents of low-density polyethylene electrets were measured versus the principal experimental variables. Several electrode types were used for the charging and discharging procedures. The results led to know the experimental conditions for the heterocharge and homocharge accumulating and decreasing. The electronic structure parameters of polyethylene such as trap level, density of traps, hopping length, mobility, trap time constants were deduced. A method for evaluating the local electric field inside the electret is proposed.

  • PDF

Design of the RLG Current Stabilizer for Attitude Control in the Satellite (저궤도 위성 자세제어용 RLG 전류 안정화 회로 설계)

  • Kim, Eui-Chan;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.98-101
    • /
    • 2008
  • In this paper, we describe the RLG current stabilizer circuit for attitude control in the satellite. The RLG makes use of the Sagnac effect within a resonant of a HeNe laser. The difference between two discharge currents causes one of the gyro bias errors. The theoretical background and current stabilizer are introduced. It is verified that the circuit designed is applicable to the test of input voltage and temperature.