• Title/Summary/Keyword: direct torque control method

Search Result 170, Processing Time 0.023 seconds

A Study on the Start-Up Scheme of Direct Vector Controlled Induction Motor System (유도전동기의 직접 벡터제어 시스템에서 기동기법에 관한 연구)

  • 전태원;최명규;유우종
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.5
    • /
    • pp.427-434
    • /
    • 2000
  • The paper proposes a zero speed start-up scheme of direct rector controlled induction motor drive without any torque jerk. At standstill condition, a method is derived to calculate a stator flux with only stator current. The programmable 3-stage low pass filters with programmable time constants is used in order to solute the problem of integration for stator flux estimation in the direct vector control mode. Due to the time delay of 3-stage low pass filter, the status flux decreases rapidly and also the torque jerk occurs during the transition from standstill mode to the direct rector control mode. A feedforward control strategy of the stator flux is suggested to prevent the torque jerk at start-up. Through results of simulation and experiment with 32 bit DSP, the performance of the start-up scheme is verified.

  • PDF

Sensorless Speed Control of Induction Motor by Direct Torque Control with Numerical Model (수식모델의 직접토크제어에 의한 유도전동기의 센서리스 속도제어)

  • Yoon, Kyoung-Kuk;Kim, Sung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.830-836
    • /
    • 2012
  • Various control algorithms have been proposed for the speed-sensorless control for an induction motor. These control schemes are mainly based on the speed feedback with the flux and speed estimations. This paper proposes another method for the speed-sensorless control for an induction motor. The proposed scheme is based on the torque and flux compensation without speed estimations, in which the same controlled stator voltage is applied to both the induction motor and the numerical model so that the differences between torques and fluxes of the model and the induction motor may be compelled to give access to zero. The results of experiment show the effectiveness of the scheme.

The Application of Classical Direct Torque and Flux Control (DTFC) for Line-Start Permanent Magnet Synchronous and its Comparison with Permanent Magnet Synchronous Motor

  • Soreshjani, Mohsen Hosseinzadeh;Heidari, Reza;Ghafari, Ahmad
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1954-1959
    • /
    • 2014
  • This paper attempts to design and present a comparison of classical Direct Torque Flux Control (DTFC) for Line-Start Permanent Magnet Synchronous Motor (LSPMSM) and its equal Permanent Magnet Synchronous Motor (PMSM). In order to present an in-depth analysis, both motors for DTFC Voltage Source Inverter (VSI)-fed in the same situations of different conditions are simulated and tested. The advantages of the proposed method for LSPMSM over the PMSM are discussed and analyzed.

Torque Ripple Reduction Method With Enhanced Efficiency of Multi-phase BLDC Motor Drive Systems Under Open Fault Conditions (다상 BLDC 모터 드라이브 시스템의 개방 고장 시 효율 향상이 고려된 토크 리플 저감 대책)

  • Kim, Tae-Yun;Suh, Yong-Sug;Park, Hyeon-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.1
    • /
    • pp.33-39
    • /
    • 2022
  • A multi-phase brushless direct current (BLDC) motor is widely used in large-capacity electric propulsion systems such as submarines and electric ships. In particular, in the field of military submarines, the polyphaser motor must suppress torque ripple in various failure situations to reduce noise and ensure stable operation for a long time. In this paper, we propose a polyphaser current control method that can improve efficiency and reduce torque ripple by minimizing the increase in stator winding loss at maximum output torque by controlling the phase angle and amplitude of the steady-state current during open circuit failure of the stator winding. The proposed control method controls the magnitude and phase angle of the healthy phase current, excluding the faulty phase, to compensate for the torque ripple that occurs in the case of a phase open failure of the motor. The magnitude and phase angle of the controlled steady-state current are calculated for each phase so that copper loss increase is minimized. The proposed control method was verified using hardware-in-the-loop simulation (HILS) of a 12-phase BLDC motor. HILS verification confirmed that the increase in the loss of the stator winding and the magnitude of the torque ripple decreased compared with the open phase fault of the motor.

Direct Instantaneous Torque Control of SRM using 4-level Converter (4-레벨 콘버터를 이용한 SRM의 순시 토오크 제어 기법)

  • Lee, Dong-Hee;Lee, Sang-Hun;Ahn, Jin-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • This paper presents a direct instantaneous torque control (DITC) of Switched Reluctance Motor (SRM) with a novel 4-level converter to develop a uniform torque and to improve a dynamic performance. The DITC method can reduce a high torque ripple of SRM. Drive efficiency and dynamic performance with conventional drive are low due to a slow excitation current build-up. Since the 4-level converter can obtain an addition boosted voltage to have a fast excitation and demagnetization, it can Improve dynamic performance and efficiency easily. To apply the DITC technique to a 4-level converter, a novel control scheme is presented according to the operating modes. Additionally, selection of capacitances of boosted capacitor and efficiency improvement of 4-level converter are analyzed. At last, the validity of proposed method is verified by some computer simulations md comparative experiments.

A Study of Using Optimal Hysteresis Band Amplitude for Direct Torque Control of Induction Motor (유도전동기 직접토크제어의 히스테리시스 밴드 크기의 최적화에 관한 연구)

  • Jeong B.H.;Kim S.K.;Park J.K.;Oh G.K.;Cho G.B.;Baek H.L.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.812-815
    • /
    • 2003
  • Most of all, DTC drive is very simple in its implementation because it needs only two hysteresis comparator and switching vector table for both flux and torque control. The switching strategy of a conventional direct torque control scheme which is based on hysteresis comparator results in a variable switching frequency which depends on the speed, flux, stator voltage and the hysteresis of the comparator. The amplitude of hysteresis band greatly influences on the drive performance such as flux and torque ripple and inverter switching frequency. In this paper the influence of the amplitudes of flux and torque hysteresis bands and sampling time of control program on the torque and flux ripples are investigated. Simulation results confirm the superiority of the DTC under the proposed method over the conventional DTC.

  • PDF

Harmonic and Torque Ripple Reduction of Electric Propulsion System using 12-Pulse Diode Rectifier by Auxiliary Supply (보조 전원을 이용한 12 펄스 다이오드 정류기를 사용하는 추진시스템의 고조파 및 토크 리플 저감)

  • Kim, Jong-Su;Seo, Dong-Hoan;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.1
    • /
    • pp.66-70
    • /
    • 2013
  • The input current of three phase rectifier which is mainly used in the propulsion system of the electric propulsion ship includes a variety of low order harmonics. To reduce these harmonics, the power conversion system, used in the large vessels which high power is required, is currently used the rectifiers of 12-pulse output, but it still has a problem that occurs $12{\pm}1$ harmonics. Also, in the case of the direct torque control technique which is widely used for the speed and torque control, the torque ripple is severe and the input current of motor has greatly included harmonics by the switching of the inverter. In order to reduce harmonics and improve the performance of torque control, this paper presents that the auxiliary supply assisted into the 12-pulse rectifier of the electric propulsion system using direct torque control technique. We confirm the validity of the proposed method through the simulation under the environment of a real vessel system.

A sensorless speed control of brushless DC motor by using direct torque control (직접토크제어에 의한 브러시리스 직류전동기의 센서리스 속도제어)

  • Yoon, Kyoung-Kuk;Oh, Sae-Gin;Kim, Deok-Ki
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.935-939
    • /
    • 2015
  • This paper describes sensorless speed control of brushless DC motors by using direct torque control. Direct torque control offers fast torque response, robust specification of parameter changes, and lower hardware and processing costs compared to vector-controlled drives. In this paper, the current error compensation method is applied to the sensorless speed control of a brushless DC motor. Through this control technique, the controlled stator voltage is applied to the brushless DC motor such that the error between the stator currents in the mathematical model and the actual motor can be forced to decay to zero as time proceeds, and therefore, the motor speed approaches the setting value. This paper discusses the composition of the controller, which can carry out robust speed control without any proportional-integral (PI) controllers. The simulation results show that the control system has good dynamic speed and load responses at wide ranges of speed.

A new approach to control of variable reluctance motors for DD robots (DD 로봇용 VR 모터의 제어를 위한 새로운 방식)

  • 김창환;하인중;하태균;고명삼;김동일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.664-669
    • /
    • 1992
  • In this paper, we present a DSP-based high dynamic performance torque control scheme of variable reluctance motors(VRM's) for DD(Direct Drive) robots via function inversion technique. The VRM with our controller behaves like DC motors, and hence developed torque tracks given torque command accurately with no torque ripples. Furthermore, our torque control algorithm ensures the production of maximum constant torque under maximum current limitation, minimizes power loss in each phase resistance, and takes magnetic saturation effect into account. Also, since our control algorithm is represented in the form of look-up table, it can be easily implemented with simple digital circuits and this tabular design method is computationally more accurate and simpler compared to the prior methods.

  • PDF

Speed Control of PMSM using DTC-PWM Approach (DTC-PWM 방식에 의한 PMSM의 속도 제어 기법)

  • Lee, Dong-Hee;Choo, Young-Bae
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.268-277
    • /
    • 2009
  • This paper presents an DTC-PWM (Direct Torque Control-Pulse Width Modulation) of PMSM (Permanent Magnet Synchronous Motor). The proposed DTC-PWM method combines a conventional DTC and PWM approach for switching signal generation. The actual torque is estimated by the torque estimator in conventional method, but the switching signal is generated by PWM method according to the switching rules and torque error. A effective voltage vector and zero vector are used to generate the switching signals and asymmetric switching method is applied. A simple calculation of PWM without any complex determination of space vector can assure the constant switching frequency with an constant torque and flux. The proposed torque control scheme for PMSM is verified by experimental results.