• Title/Summary/Keyword: direct test

Search Result 3,324, Processing Time 0.031 seconds

Shear Strength Model for Interior Flat Plate-Column Connections (무량판 슬래브-기둥 내부 접합부에 대한 전단강도모델)

  • Choi, Kyoung-Kyu;Park, Hong-Gun
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.345-356
    • /
    • 2010
  • An alternative design method for interior flat plate-column connections subjected to punching shear and unbalanced moment was developed. Since the slab-column connections are severely damaged by flexural cracking before punching shear failure, punching shear was assumed to be resisted mainly by the compression zone of the slab critical section. Considering the interaction with the flexural moment of the slab, the punching shear strength of the compression zone was evaluated based on the material failure criteria of concrete subjected to multiple stresses. The punching shear strength was also used to evaluate the unbalanced moment capacity of the slab-column connections. For verification, the proposed strength model was applied to existing test specimens subjected to direct punching shear or combined punching shear and unbalanced moment. The results showed that the proposed method predicted the strengths of the test specimens better than current design methods in ACI 318 and Eurocode 2.

Direct Punching Shear Strength Model for Interior Slab-Column Connections and Column Footings with Shear Reinforcement (전단 보강 슬래브-기둥 내부 접합부 및 기초판에 대한 뚫림 전단강도 모델)

  • Choi, Kyoung-Kyu;Kim, Sug-Hwan;Kim, Dong-Hoon;Park, Hong-Gun
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.2
    • /
    • pp.159-168
    • /
    • 2011
  • In the present study, an improved design method was developed for the punching shear strength of interior slabcolumn connections and column footings with and without shear reinforcement. In the evaluation of the punching shear strength, the possible failure mechanisms of the connections and column footings were considered. The considered failures modes were inclined tensile cracking of concrete, yielding of shear re-bars, and concrete crushing of compression zone/strut. The punching shear applied to the concrete critical section was assumed to be resisted mainly by the compression zone. The punching shear strength of the concrete compression zone was evaluated based on the material failure criteria of the concrete subjected to the compressive normal stress and shear stress. For verification of the proposed design method, its prediction was compared with the existing test results. The result showed that the proposed method predicted the strengths of the test specimens better than the current design methods of the KCI code for both the shear reinforced and unreinforced cases.

Rheological Models for Simulations of Concrete Under High-Speed Load (콘크리트 재료의 동적 물성 변화를 모사하기 위한 유변학적(Rheological)모델 개발 및 평가)

  • Hwang, Young Kwang;Lim, Yun Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.4
    • /
    • pp.769-777
    • /
    • 2015
  • In this study, the rheological models were introduced and developed to reflect rate dependent tensile behaviour of concrete. In general, mechanical properties(e.g. strength, elasticity, and fracture energy) of concrete are increased under high loading rates. The strength of concrete shows high rate dependency among its mechanical properties, and the tensile strength has higher rate dependency than the compressional strength. To simulate the rate dependency of concrete, original spring set of RBSN(Rigid-Body- Spring-Network) model was adjusted with viscous and friction units(e.g. dashpot and Coulomb friction component). Three types of models( 1) visco-elastic, 2) visco-plastic, and 3) visco-elasto- plastic damage models) are considered, and the constitutive relationships for the models are derived. For validation purpose, direct tensile test were simulated, and characteristics of the three different rheological models were compared with experimental stress-strain responses. Simulation result of the developed visco-elasto-plastic damage(VEPD) model demonstrated well describing and fitting with experimental results.

A Comparison of Self-Reported Fatigue and Fatigue-Regulating Behaviors of Rheumatoid Arthritic Patients and Normal Persons (류마티스관절염 환자와 정상인의 피로도 및 피로조절행위 비교)

  • Jung, Bok-Hee;Kim, Myung-Ae
    • Journal of muscle and joint health
    • /
    • v.6 no.1
    • /
    • pp.51-72
    • /
    • 1999
  • The purpose of this study is to compar self-reported fatigue and fatigue-regulating behaviors of rheumatoid arthritic patients and normal persons. This study collected the data from 75 rheumatoid arthritic patents visited the departments of internal medicine or orthopedics of four general hospitals T-city and K-city by means of direct interview and questionnaires. in this study also collected data from 75 normal persons who had not been exposed to any other disease in T-city and K-city by means of direct interviews anti questionnaires which were conducted by two trained nurses. This experiment was conducted from August 1, 1998 to October 15, 1998. This study used both MAP(Multi-Dimentional Assessment of Fatigue) developed by Belza(1995) to measure fatigue and the measurement developed by Kwon, Young-Eun to investigate fatigue regulating behaviors. The collected materials were analyzed by means of descriptive statistics, t-test, and the ANCOVA according to the SPSS PC+ program. The findings are as follows : 1. There was the statistically significant difference(t =5.07, p=.000), between rheumatoid arthritic patients(32.76 points) and normal persons(25.81 points) in t-test comparison by group about fatigue. A fatigue degree of rheumatoid arthritic patient group was high in five kinds of lower realms such as common fatigue degree, fatigue severity to be experienced, distress due to fatigue, daily fatigue degree, and fatigue timing at the last week by dimension. 2. There was the significant difference in the number of fatigue-regulating behaviors between rheumatoid of fatigue arthritic patients(9.37 times) and normal persons (8.15 times), but there wasn't any significant difference in the efficiency between rheumatoid arthritic patients(2.85 points) and normal persons (2.78 points) This research suggests two kinds of things as follows : 1. It is necessary to develop an educational program for improving efficiency of fatigue-regulating behaviors as well as some nursing arbitration measures for reducing fatigue of rheumatoid arthritic patients. 2. It is necessary for the future studies to continuously grasp characteristics of fatigue by gender variable by selecting more rheumatoid arthritic male patients.

  • PDF

Antioxidative and Antimutagenic Effects of Ganoderma lucidum Krast Extracts (영지버섯(Ganoderma lucidum Krast) 추출물의 항산화 및 항돌연변이 효과)

  • Oh Se-In;Lee Mee-Sook
    • The Korean Journal of Food And Nutrition
    • /
    • v.18 no.1
    • /
    • pp.54-62
    • /
    • 2005
  • The antioxidative effect, antimutagenic capacity and inhibitory effect of cancer cell proliferation in ethanol extracts of Ganoderma lucidum were studied for suggestion of prevention and dietetic treatment of chronic diseases and development of antioxidative, antimutagenic and anticancer functional food by employing biological and biochemical assay. The IC/sub 50/ of MDA with BSA conjugation reaction, lipid peroxidation and scavenging effect on DPPH radical in ethanol extracts of Ganoderma lucidum showed 1026.21 mg/mL, 0.152 mg/mL and 0.412 mg/mL, respectively. So, the most effective antioxidative capacity in ethanol extracts of Ganoderma lucidum was the lipid peroxidation, among the method used this study. The indirect and direct antimutagenic effects of ethanol extracts of Ganoderma lucidum were examined by Ames test using Salmonella typimurium TA98 and TA100. The inhibition rates on indirect mutagenicity mediated by 2-Anthramine showed 100% in the Salmonella typimurium TA98 and 98.74% in the Salmonella typimurium TA100 and the direct mutagenicity mediated by sodium azide in Salmonella typimurium TA100 was 82.96%. But, the inhibitory effect on indirect mutagenicity mediated by 2-Nitrofluorene in Salmonella typimurium TA98 was low(7.81%). The inhibitory Effect of Ganoderma lucidum ethanol extracts on cell proliferation in Hela and MCF-7 by MTT test were 74.36% in HeLa and 73.90% in MCF-7 at the 0.50 mg/assay concentration and IC/sub 50/ were 0.163 mg/mL and 0.196 mg/mL respectively. From this result, it is suggested that Ganoderma lucidum is believed to have a possible antioxidative, antimutagenic and anticancer capacities.

Assessment of Productivity and Foodservice Management Practices in Elementary School Foodservices Located in Seoul and KangNung (서울.강릉지역 초등학교 급식소의 급식생산성 분석)

  • 김은경;김은미;강명희;홍완수
    • Korean journal of food and cookery science
    • /
    • v.14 no.1
    • /
    • pp.76-83
    • /
    • 1998
  • The purpose of this study was to evaluate the foodservice management practices and productivity in elementary schools in order to provide basic information for an efficient food service management. This approach was achieved using a variety quantitative and qualitative information including general foodservice management, managerial and operational factors, and the productivity in elementary school foodservice systems. The labor productivity in 28 school foodservice system was assessed and related to a number of influencing variables within the system. The productivity measurement was based upon the total meal equivalents as a ratio of the total direct and non-direct labor hours required to prepare these meals. Twenty-eight elementary schools located in Seoul and Kangnung were surveyed to get data for the variables. Questionnaire and a survey form were mailed. Statistical methods used in this study were descriptive analysis, $\chi$$^2$-test, 1-test and one-way ANOVA analysis. Elementary schools in Seoul were all located in urban areas, whereas elementary schools in Kangnung were in urban areas (40.0%), provincial areas (40.0%) and in isolated areas (20.0%). Total average number of meals including children and staff was 928.2${\pm}$ 650.0 with a yery significant difference (p<0.001) between Seoul and Kangnung. The average cost of school meal in Seoul and Kangnung were 1191.0 won and 1526.2 won, respectively. The result of Pearson Correlation analysis indicated that labor cost per meal, 1-week meal equivalents and meal equivalents per labor were significantly correlated with the productivity.

  • PDF

전기화학공정을 이용한 질화규소방열기판 상 금속 전극 형성에 관한 연구

  • Sin, Seong-Cheol;Kim, Ji-Won;Gwon, Se-Hun;Im, Jae-Hong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.129.1-129.1
    • /
    • 2016
  • 반도체, 디스플레이, PC 등 전자기기의 경우 소자 내 발생된 열로 인해 기기의 성능 및 효율, 수명 등이 감소하기 때문에 이러한 내부 열을 외부로 방출시켜줄 필요가 있다. 일반적으로 heat pipe나 냉각 팬(fan) 등의 외부장치에 의해 강제적으로 냉각해주는 기술이 있지만 휴대용 디바이스와 같이 작은 전자기기의 경우 소자 자체적으로 열전도 특성이 뛰어난 기판을 사용하여 열전도에 의해 열이 소자 밖으로 방출될 수 있도록 방열 설계를 해주어야 한다. 따라서 소자 전체를 지지해주고 열전도에 의해 방열 기능을 해주는 방열기판에 대한 관심이 증가하고 있다. 현재 가장 많이 사용되어지는 세라믹 방열기판으로는 알루미나가 있지만 보다 소자의 집적화와 고성능화로 인하여 열전도도가 높은 질화규소 기판의 요구가 증대되고 있다. 하지만 이러한 질화규소기판에 금속전극을 형성하는 기술은 종래의 알루미나 기판에 이용한 DPC(Direct Plated Copper), DBC(Direct Bonded Copper)기술을 적용할 수 없다. 그래서 현재는 메탈블레이징을 이용하여 전극을 형성하지만 공정비용 및 대형기판에 형성이 어려운 단점이 있다. 따라서, 본 연구에서는 질화규소 방열기판에 전기화학공정을 통하여 밀착력이 우수한 금속 전극 회로층 형성에 대한 연구를 진행하였다. 질화규소 방열기판에 무전해 Ni 도금을 통하여 금속층을 형성하는데 이 때 세라믹 기판과 금속층 사이의 낮은 밀착력을 향상시키기 위해 습식공정을 통하여 표면처리를 진행하였다. 또한 촉매층을 $Pd-TiO_2$ 층을 이용하여 무전해 도금공정을 이용하여 Ni, 전극층을 형성하였다. 질화규소 표면에 OH기 형성을 확인하기 위해 FT-IR(Fourier-transform infrared spectroscopy)분석을 실시하였으며 OH 그룹 형성 및 silane의 화학적 결합으로 인해 금속 전극층의 밀착력이 향상된 것을 cross hatch test 및 scratch test를 통해 확인하였고 계면 및 표면형상 특성 등을 분석하기 위해 TEM(Transmission electron microscopy), SEM(Scanning electron microscopy), AFM(Atomic-force microscopy)등의 장비를 이용하였다.

  • PDF

The Effects of Transcranial Direct Current Stimulation in Motor Performance of Serial Reaction Time Task (경두개직류전류자극이 시열반응과제에 대한 운동 수행 능력에 미치는 영향)

  • Kim, Chung-Sun;Nam, Seok-Hyun;Cho, In-Sul
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.5
    • /
    • pp.103-108
    • /
    • 2010
  • Purpose: The aim of this study is to investigate whether motor cortex excitability by transcranial direct current stimulation (tDCS) over primary motor cortex (M1) affects motor performance of serial reaction task. Methods: Cathodal, anodal and sham tDCS (1 mA) are applied over right M1 of 24 subjects for 30 minutes including 11minutes for task period time. We applied two electrodes at the same position to both an experimental group and a sham-controlled group, and we made 2 groups recognize to be applicated of stimulation. Flexion, extension of wrist and thumb flexion are carried out following colors of arrows on the monitor. Serial reaction time task was applied to confirm the difference of the reaction time between 2 groups. Results: Reaction time is decreased in both tDCS-group and Sham-controlled tDCS group, and the degree of reduction is much greater in the post-test than pre-test. Reduction of reaction time between groupsis statistically significant. Conclusion: We consider that anodal tDCS increased the cortical excitability of the underlying motor cortex and it can be helpful to modulate motor performance. It seems that tDCS is an effective modality to modulate brain function, and it will be great help to mediate strategy for the brain injury patients.

An Experimental Study on Structural Capacity of Joint Between Composite PHC Wall Pile and Bottom Slab with CT Shear Connector (CT형강 전단연결재가 적용된 합성형 PHC벽체파일-하부슬래브 연결부 성능에 관한 실험적 연구)

  • Mha, Ho Seong;Won, Jeong Hun;Lee, Jong Ku
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.5
    • /
    • pp.531-541
    • /
    • 2013
  • This paper investigated the structural capacity of the CT shear connectors, which is a kind of the perfobond rib and functions as an anchor transferring the tension force in the joint between a composite PHC wall pile and a bottom slab. The direct pull-out test was performed for various specimens. From failure modes and load-displacement curves, it was found that transverse rebars should be placed to holes in a web to restrict pull-out failure of CT shear connectors. The results of additional tests for specimens with transverse rebars and various support lengths indicated that all specimens were failed by the tension failure of PHC pile before pull-out failure of CT shear connector and concrete pull-out failure. Thus, the CT shear connector could endure the tension force between the PHC wall pile and the bottom slab.

What is the Role of Supplier Learning Capacity on Technological Innovation in Supplier Development? (공급자 개발에서 공급자의 학습역량은 기술혁신에 어떠한 역할을 하는가?)

  • Park, Jinhan;Kim, Jin-Han
    • Journal of Technology Innovation
    • /
    • v.23 no.3
    • /
    • pp.255-286
    • /
    • 2015
  • This study focuses on the role of supplier's organizational learning capacity in creating the outcomes of technological innovation based on buyer-supplier collaboration. In doing so, the study is carried out through mediating effect analysis using 221 small and medium enterprises among Korean manufacturers. As a result of empirical tests, buyer's indirect supports(knowledge, know-how, value, information sharing) have significant and positive effects on the outcomes of technological innovation, whereas direct supports(technical staff support, machine tools and test equipments support, education for facility utilization) show no statistical significance. In addition, a further test for mediation effects reveals that a full mediation exists between supplier learning capacity and buyer's direct support, while there is a partial medication effect for buyer's indirect support. The findings suggest that buyer's indirect support can take on more important role to enhance the outcomes of supplier's technological innovation.