• 제목/요약/키워드: direct determination

검색결과 511건 처리시간 0.023초

형광 X선에 의한 대기분진중의 미량성분의 측정(II): 대기부유분진 중 경원소의 X-선 형광분석 (Determination of Trace Elements in Atmospheric Dust by X-Ray Fluorescence Spectrometry(II) : X-ray Fluorescence Spectrometric Determination of Light Elements)

  • 이용근;박현미;이동수;이보경
    • 한국대기환경학회지
    • /
    • 제9권3호
    • /
    • pp.247-254
    • /
    • 1993
  • A simple and direct method is developed for the determination of light Elements in atmospheric particulates by X-ray fluorescence spectrometry. Calibration standards for the light elements such as Al, Mg, K, Ca, etc are prepared by filtering real atmospheric particulates over variable time and subsequently standardizing them by Inductively Coupled Plasma-Mass Spectrometry(ICP-MS) or Atomic Absorption Spectrophotometry(AAS) analysis. The validity of this calibration method is tested by analyzing more than 100 aerosol samples, collected at urban(Seoul) and rural(Padori) sites over a two year period with this method and then comparing them with those by other accuracy proven methods such as AAS or ICP-MS: for all metals tested the results showed reasonably good agreements (R $\geq$ 0.95).

  • PDF

원자흡광분광분석법에 의한 혈청 Zn의 측정 (Direct Determination of Serum Zinc by Atomic Absorption Spectroscopy)

  • 채범석;석영건;박동수
    • Journal of Nutrition and Health
    • /
    • 제4권3호
    • /
    • pp.1-4
    • /
    • 1971
  • Zinc is an essential trace element. Previos methods for the determination of zinc in serum have been difficult and reported findings must be treated with caution. The normal range of zinc in serum varies significantly according to different methods and author. The scope of this work was to establish the normal range of zinc in serum values in healthy Korean persons. Methods are described for the determination of zinc in serum diluted ten-fold with deionised water using Hitachi Model 207, atomic absorption spectrophotometer. The values of zinc in serum of 23 healthy Korean persons by atomic absorption spectroscopy ranged from 87.6 to $131.2\;{\mu}g/100\;ml$ with the mean value $109.1\;{\mu}g/100\;ml$ and standard deviation 10.86. In this method, satifactory result was obtained with regard to the coefficient variation and recoveries of added zinc in the measurenents.

  • PDF

Attitude determination for three-axis stabilized satellite

  • Kim, Jinho;Lew, Changmo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.110-114
    • /
    • 1995
  • This paper presents the on-board attitude determination algorithm for LEO (Low Earth Orbit) three-axis stabilized spacecraft. Two advanced star trackers and a three-axis Inertial Reference Unit (IRU) are assumed to be attitude sensors. The gyro in the IRU provides a direct measurement of the attitude rates. However, the attitude estimation error increases with time due to the gyro drift and noise. An update filter with measurements of star trackers and/or sun sensor is designed to update these gyro drift bias and to compensate the attitude error. Kalman Filter is adapted for the on-board update filter algorithm. Simulation results will be presented to investigate the attitude pointing performance.

  • PDF

이온교환체로서 금속-디-2-피리딜케톤옥심-산성의약품 3원 착물을 이용한 산성의약품의 정량 (Determination of Acidic Drug with ISEs Using Ternary Complex of Metal-di-2-pyridyl Ketone Oxime-acidic Drug as Ion-Exchanger)

  • 안문규;오원정;이언경;이순영;이재윤;정문모;허문회
    • 약학회지
    • /
    • 제46권5호
    • /
    • pp.320-323
    • /
    • 2002
  • A method for the determination of acidic drug, mefenamic acid and ibuprofen with ion-selective electrode(ISE) using Fe(II)-di-2-pyridyl ketone oxime complex as a counter ion were developed. Benzyl-2-nitrophenyl ether(BNPE) plasticized membrane was more selective and sensitive than the other tested membranes. The acidic drug selective electrode exhibits a linear response for 10$^{-2}$ M 510$^{-5}$ M of acidic drugs, mefenamic acid and ibuprofen with a slope of -55.9 and -56.3 mV/dec. in borate buffer solution (pH 8.9). Potentiometric selectivity measurements revealed negligible interferences from aromatic and aliphatic carboxylic acid salts. The electrodes were found to be useful for the direct determination of mefenamic acid and ibuprofen in pharmaceutical preparations.

Mercapto 화합물에 의한 은의 정량 (제3보). 2-Mercaptothiazoline에 의한 은의 전류적정 (Determination of Silver with Mercaptans (III). Amperometric Titration of Silver with 2-Mercaptothiazoline)

  • 하영구
    • 대한화학회지
    • /
    • 제17권6호
    • /
    • pp.439-443
    • /
    • 1973
  • 은에 한하여 대단히 예민한 시약으로서 2-mercaptothiazoline를 알게 되었으며, 이 시약으로 은의 전류법 정량에 뛰어나게 이용할 수 있다. 이 방법은 암모니아 수용액에서 2-mercaptothiazoline으로써 전류법적정에 의한 미량의 은을 정량하는데 EDTA를 막기제로 사용하여 많은 다른 이온들의 존재하에 대기중에서 미량의 은을 직접 적정할 수가 있었으며 방해 이온들은 금과 백금 뿐이나, 미량의 은을 이 방법에 의하여 상대오차 ${\pm}$5% 이내로 정량할 수 있다.

  • PDF

$Cs^{137}$의 迅速定量法 (Rapid Determination of Cesium-137)

  • 김태순;박태원;이춘영;서경숙
    • 대한화학회지
    • /
    • 제5권1호
    • /
    • pp.29-32
    • /
    • 1961
  • Two methods for the determination of Cesium-137 in various foods(ashes) were compared. The one comprises two steps, the first being the separation of alkalies as cobaltinitrites or perchlorates by the radiochemical method, and the second being the measurement of photopeak area due to the presence of Cs-137 by the use of scintillation spectrometer. The other method is the direct subjection of ash samples to the spectrometry without the radiochemical separation. The combined contribution of K-40 and Rb-87 to the spectrum was not found on account of the difference in energies of these nuclides. These two methods gave, a good agreement in the determination of Cs-137 in 50-100g ash samples of vegetables or cereals under investigation.

  • PDF

Potentiometric sensor of graphene oxide decorated with silver nanoparticles/molecularly imprinted polymer for determination of gabapentin

  • Abdallah, Nehad A.;Ibrahim, Heba F.
    • Carbon letters
    • /
    • 제27권
    • /
    • pp.50-63
    • /
    • 2018
  • An imprinted potentiometric sensor was developed for direct and selective determination of gabapentin. Sensor is based on carbon paste electrode adapted by graphene oxide that is decorated with silver nanoparticles and mixed with molecularly imprinted polymers nanoparticles using gabapentin as a template molecule. The synthesized nanoparticles were characterized by Fourier transmission infrared spectroscopy, transmission electron microscopy and X-ray diffraction. Under optimal experimental conditions, the studied sensor exhibited high selectivity and sensitivity with LOD of $4.8{\times}10^{-11}mol\;L^{-1}$. It provided a wide linearity range from $1{\times}10^{-10}$ to $1{\times}10^{-3}mol\;L^{-1}$ and high stability for more than 3 mo. The sensor was effectively used for the determination of gabapentin in pharmaceutical tablets and spiked plasma samples.

Development of Delay Responsibility Determination Model based on the Probabilistic Risk Analysis

  • Cho, Ji Hoon;Lim, Dong Yui;Kim, Sang Bum
    • 국제학술발표논문집
    • /
    • The 6th International Conference on Construction Engineering and Project Management
    • /
    • pp.599-599
    • /
    • 2015
  • This research attempts to resolve the construction delay issues of indirect delays by developing the "Delay Responsibility Determination Model" (DRM) based on probabilistic risk analysis. DRM is envisioned to provide a way of quantitatively analyzing impacts of delayed activities while considering both direct and indirect influences. With the successful development of DRM, it would be possible to present relative probabilistic measures to all the related stakeholders in terms of their contributions to schedule delays. Upon the development completion of DRM, "Korean Construction Delay Claim/Dispute Resolution Protocols" will also be prepared to facilitate the effective use of DRM.

  • PDF

2단 평행기구 로봇 암의 실시간 순방향 기구학 해석 (Real-time direct kinematics of a double parallel robot arm)

  • 이민기;박근우
    • 대한기계학회논문집A
    • /
    • 제21권1호
    • /
    • pp.144-153
    • /
    • 1997
  • The determination of the direct kinematics of the parallel mechanism is a difficult problem but has to be solved for any practical use. This paper presents the efficient formulation of the direct kinematics for double parallel robot arm. The robot arm consists of two parallel mechanism, which generate positional and orientational motions, respectively. These motions are decoupled by a passive central axis which is composed of four revolute joints and one prismatic joint. For a set of given lengths of linear actuators, the direct kinematics will find the joint displacements of th central axis from geometric constraints in each parallel mechanism. Then the joint displacements will be converted into the position and the orientation of the end effector of the robot arm. The proposed formulation is decoupled and compacted so that it will be implemented as a real-time direct kinematics. With the proposed formulation, we analyze the motion of the double parallel robot and show its characteristics. Specially, we investigate the workspace in terms of positional space as well as orientational space.

Numerical simulation of tensile failure of concrete using Particle Flow Code (PFC)

  • Haeri, Hadi;Sarfarazi, Vahab
    • Computers and Concrete
    • /
    • 제18권1호
    • /
    • pp.39-51
    • /
    • 2016
  • This paper considers the tensile strength of concrete samples in direct, CTT, modified tension, splitting and ring tests using both of the experimental tests and numerical simulation (particle flow code 2D). It determined that which one of indirect tensile strength is close to direct tensile strength. Initially calibration of PFC was undertaken with respect to the data obtained from Brazilian laboratory tests to ensure the conformity of the simulated numerical models response. Furthermore, validation of the simulated models in four introduced tests was also cross checked with the results from experimental tests. By using numerical testing, the failure process was visually observed and failure patterns were watched to be reasonable in accordance with experimental results. Discrete element simulations demonstrated that the macro fractures in models are caused by microscopic tensile breakages on large numbers of bonded discs. Tensile strength of concrete in direct test was less than other tests results. Tensile strength resulted from modified tension test was close to direct test results. So modified tension test can be a proper test for determination of tensile strength of concrete in absence of direct test. Other advantages shown by modified tension tests are: (1) sample preparation is easy and (2) the use of a simple conventional compression press controlled by displacement compared with complicate device in other tests.