• Title/Summary/Keyword: digital replica

Search Result 65, Processing Time 0.029 seconds

A Study for the Broadcasting Makeup and Image Representation Changes in the Digital Media Era (디지털 미디어 시대의 방송 분장 변화에 관한 연구)

  • Barng, Kee-Jung;Kim, Kyung-Hee;Kim, Ju-Duck
    • The Research Journal of the Costume Culture
    • /
    • v.18 no.6
    • /
    • pp.1194-1210
    • /
    • 2010
  • The influence of digital media according to environmental change of multi-media came to have significance more than what we imagine. In accordance with high resolution of HDTV in digital media era, the cautious awareness is required for skin color by the immediate color such as replica of TV color, lighting and clothing. As for the broadcasting makeup expression technique caused by a change in broadcasting environment in the digital media era, the first, There is necessity for natural makeup technique, and for expressing the whole makeup evenly and very delicately. The makeup work gets much more delicate. For the delicate expression, more time is being required than the existing makeup time. Second, Lots of time and manpower are required for elaborate real-object processing on all the production fields such as background set, stage properties, and makeup. Third, Realistic expression is available on the screen. Importance of basic makeup is highlighted. Thus, even the skin care shop came to be prevalent. Development in only HD cosmetics is needed for foundation with fine particle in new material and with diverse colors hereafter. The video-media field is a method that is ignored a sense of distance through vehicles such as camera, picture tube, and several kinds of broadcasting machinery and equipment and that is delivered vividly to viewers through screen, unlike the stage makeup, thereby being needed the makeup technology proper for HDTV according to the changing broadcasting environment and media. The video machinery and equipment are proceeding with being gradually high-tech and precise. Thus, an expert in makeup needs to know common sense on the video machinery and equipment before makeup, and needs to make an effort according to it. And, a follow-up research can be said to be necessary on the advance in makeup method and on more diverse dedicated cosmetics along with a research on color tone proper for HDTV.

Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes

  • von Maltzahn, Nadine Freifrau;Bernhard, Florian;Kohorst, Philipp
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.2
    • /
    • pp.100-106
    • /
    • 2020
  • PURPOSE. The purpose of this in vitro study was to evaluate the fitting accuracy of single crowns made from a novel presintered Co-Cr alloy prepared with a computer-aided design and computer-aided manufacturing (CAD/CAM) technique, as compared with crowns manufactured by other digital and the conventional casting technique. Additionally, the influence of oxide layer on the fitting accuracy of specimens was tested. MATERIALS AND METHODS. A total of 40 test specimens made from Co-Cr alloy were investigated according to the fitting accuracy using a replica technique. Four different methods processing different materials were used for the manufacture of the crown copings (milling of presintered (Ceramill Sintron-group_cer_sin) or rigid alloy (Tizian NEM-group_ti_nem), selective laser melting (Ceramill NPL-group_cer_npl), and casting (Girobond NB-group_gir_nb)). The specimens were adapted to a resin model and the outer surfaces were airborne-particle abraded with aluminum oxide. After the veneering process, the fitting accuracy (absolute marginal discrepancy and internal gap) was evaluated by the replica technique in 2 steps, before removing the oxide layer from the intaglio surface of the crowns, and after removing the layer with aluminum oxide airborne-particle abrasion. Statistical analysis was performed by multifactorial analysis of variance (ANOVA) (α=.05). RESULTS. Mean absolute marginal discrepancy ranged between 20 ㎛ (group_cer_npl for specimens of Ceramill NPL) and 43 ㎛ (group_cer_sin for crowns of Ceramill Sintron) with the oxide layer and between 19 ㎛ and 28 ㎛ without the oxide layer. The internal gap varied between 33 ㎛ (group_ti_nem for test samples of Tizian NEM) and 75 ㎛ (group_gir_nb for the base material Girobond NB) with the oxide layer and between 30 ㎛ and 76 ㎛ without the oxide layer. The absolute marginal discrepancy and the internal gap were significantly influenced by the fabrication method used (P<.05). CONCLUSION. Different manufacturing techniques had a significant influence on the fitting accuracy of single crowns made from Co-Cr alloys. However, all tested crowns showed a clinically acceptable absolute marginal discrepancy and internal gap with and without oxide layer and could be recommended under clinical considerations. Especially, the new system Ceramill Sintron showed acceptable values of fitting accuracy so it can be suggested in routine clinical work.

Development of a new lifetime prediction method for gas turbine core parts by digital image analysis of precipitates morphology (석출물 형상의 디지털 이미지 분석에 의한 가스터빈 핵심부품의 새로운 수명평가기술 개발)

  • Chang, Moon Soo;An, Seong Uk
    • Analytical Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.148-157
    • /
    • 2008
  • To describe the lifetime prediction of gas turbine core parts serviced in some ten thousands rpms at over $1,000^{\circ}C$, the Larson-Miller Creep Curves, which are formed by creep rupture tests as the destructive experiment with parameters of stress and temperature, are used often, but not exact and reliable with errors of over some tens. On the other hand, this study shows a non-destructive method with increased accuracy and reliability. The SEM and TEM specimens were extracted by replica after polishing the local airfoil and root surfaces of the first stage scraped blade (bucket), serviced for 18,000 hours at $1,280^{\circ}C$ in Gas Turbines of Boryong. The observed TEM and SEM precipitates were digitalized for calculation of the average size. Here we could find the precipitate size grown from $0.45{\mu}m$ to $0.6{\mu}m$ during service and the grown precipitates to be still sound. From these results we could conclude that the scraped balde can be used for ten thous and hours additionally and for twenty thousand hours by additional heat treatments on the scraped blade.

Development of Continuous UV Nano Imprinting Process Using Pattern Roll Stamper (패턴 롤 스템퍼를 이용한 연속 UV 나노 임프린팅 공정기술 개발)

  • Cha, J.;Ahn, S.;Han, J.;Bae, H.;Myoung, B.;Kang, S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.105-108
    • /
    • 2006
  • It has been issued to fabricate nano-scale patterns with large-scale in the field of digital display. Also, large-scale fabrication technology of nano pattern is very important not only for the field of digital display but also for the most of applications of the nano-scale patterns in the view of the productivity. Among the fabrication technologies, UV nano imprinting process is suitable for replicating polymeric nano-scale patterns. However, in case of conventional UV nano imprinting process using flat mold, it is not easy to replicate large areal nano patterns. Because there are several problems such as releasing, uniformity of the replica, mold fabrication and so on. In this study, to overcome the limitation of the conventional UV nano imprinting process, we proposed a continuous UV nano imprinting process using a pattern roll stamper. A pattern roll stamper that has nano-scale patterns was fabricated by attaching thin metal stamper to a roll base. A continuous UV nano imprinting system was designed and constructed. As practical examples of the process, various nano patterns with pattern size of 500, 150 and 50nm were fabricated. Finally, geometrical properties of imprinted nano patterns were measured and analyzed.

  • PDF

Analysis of quality for fixed prostheses fabricated by dental CAD-CAM system (치과용 캐드캠 시스템으로 제작된 고정성 보철물의 품질 분석)

  • Kim, Won-Soo;Han, Man-So;Jung, Jae-Kwan;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.36 no.3
    • /
    • pp.159-164
    • /
    • 2014
  • Purpose: The purpose of this study was analysis of quality of fixed prostheses fabricated by dental CAD/CAM system. Methods: The ten same cases of stone models were manufactured by dental scannable model, and stone models were scanned using the dental scanner for changing digital model. Ten digital models were completed. The design of zirconia core for zirconia based all-ceramic crown was conducted by the dental CAD program. The samples were fabricated using the pre-sintered zirconia block by dental milling machine. Marginal gaps were analyzed using by silicone replica technique at the eight parts for quality analysis of samples. One-way ANOVA was used for statistical analysis(${\alpha}=0.05$). Results: The mean for marginal gaps were $93.2{\sim}99.1{\mu}m$ at the eight parts. One-was ANOVA didn't show significant differences(p=0.089). Conclusion: The fixed dental prostheses fabricated by dental CAD/CAM were within clinically acceptable range.

Analysis of the quality of dental prostheses printed by digital light-processing technology (디지털 광공정 방식에 의해 출력된 치과용 보철물의 품질 분석)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.42 no.3
    • /
    • pp.197-201
    • /
    • 2020
  • Purpose: This study aimed to assess the quality of dental prostheses printed by digital light-processing (DLP) technology. Methods: Ten experimental models were prepared. The ten specimens that were printed by DLP technology constituted the DLP group. The ten specimens that were produced in the same model by the casting method constituted the control group. The marginal gaps of the 20 specimens produced were measured. These gaps were measured by a silicon replica technique at two abutments of the specimen. Therefore, 20 marginal gaps were measured in each group. An independent sample t-test was performed to compare the marginal gaps measured in the two groups (α=0.05). Results: According to the results of the measurement, there was a significant difference between the mean marginal gap of the control group (78.8 ㎛) and that of the DLP group (91.5 ㎛), p<0.001. Conclusion: Although the mean marginal gaps of dental fixed prostheses produced by the DLP method was higher than the mean marginal gap of those produced by the casting method, it was considered to be within the clinical threshold value suggested by some previous studies.

Ultra Wideband Channel Model for Indoor Environments

  • Alvarez, Alvaro;Valera, Gustavo;Manuel Lobeira;Torres, Rafael-Pedro;Garcia, Jose-Luis
    • Journal of Communications and Networks
    • /
    • v.5 no.4
    • /
    • pp.309-318
    • /
    • 2003
  • This paper presents an in-depth study of a UWB indoor radio channel between 1 and 9 GHz, which was used for the subsequent development of a new statistical UWB multipath channel model, focusing on short range indoor scenarios. The channel sounding process was carried out covering different indoor environments, such as laboratories, halls or corridors. A combination of new and traditional parameters has been used to accurately model the channel impulse response in order to perform a precise temporal estimation of the received pulse shape. This model is designed specifically for UWB digital systems, where the received pulse is correlated with an estimated replica of itself. The precision of the model has been verified through the comparison with measured data from equivalent scenarios and cases, and highly satisfactory results were obtained.

Analysis of internal fitness of single crown fabricated by additive method (첨가법에 의해 제작된 단관의 내면 적합도 분석)

  • Kim, Won-Soo
    • Journal of Technologic Dentistry
    • /
    • v.37 no.4
    • /
    • pp.229-234
    • /
    • 2015
  • Purpose: The purpose of this study was to analysis the internal fitness of single crown fabricated by additive method technique. Methods: Study models were fabricated. Ten crowns were manufactured by additive method technique (AM group) and another ten crowns using conventional method were manufactured (CM group). The internal fitness of specimens were measured using silicone replica technique. Silicone replicas were sectioned one times (direction: from mesial to distal). The internal fitness were evaluated using by digital microscope. Statistical analyses were performed with independent samples t-test. (${\alpha}=0.05$). Results: Mean(SD) of all internal fitness were $92.1(20.0){\mu}m$ for AM group and $69.7(12.3){\mu}m$ for CM group. Two groups were statistically significant differences (p<0.001). Conclusion: All internal gaps of AM group were ranged within the clinical recommendation ($120{\ss}{\neq}$).

An evaluation of quality of dental prostheses printed by dental 3-dimensional printing system (치과용 3D 프린팅 시스템에 의해 출력된 보철물의 품질 평가)

  • Han, Man-So
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.185-191
    • /
    • 2016
  • Purpose: The purpose of this study were to evaluate the quality of dental prostheses printed by 3-dimensional printing system. Methods: Mater model was prepared and ten study models were fabricated. Ten single crowns were printed by 3D-printing system(Resin group) and another ten single crowns using casting method were manufactured(Metal group). The marginal adaptation of single crowns were measured using by silicone replica technique. Silicone replicas were sectioned four times. The marginal adaptations were evaluated using by digital microscope. Statistical analyses were performed with Mann-Whitney test(${\alpha}=0.05$). Results: $Mean{\pm}standard$ deviations of all marginal adaptations were $92.1(20.0){\mu}m$ for Metal group and $69.7(12.3){\mu}m$ for Resin group. Two groups were no statistically significant differences(p>0.05). Conclusion: Marginal adaptation of single crowns printed by 3D-printing system were ranged within the clinical recommendation.

Evaluation of clinical adaptation of dental prostheses printed by 3-dimensional printing technology (3D 프린팅 기술로 출력된 치과 보철물의 임상적 적합도 평가)

  • Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.41 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • Purpose: The objectives of this study was to evaluate clinical adaptation of dental prostheses printed by 3 dimensional(3D) printing technology. Methods: Ten study models were prepared. Ten specimens of experimental group were printed by 3D printing(3DP group). As a control group, 10 specimens were fabricated by casting method on the same models. Marginal gaps of all specimens were measured to evaluate clinical adaptation. Marginal adaptations were measured using silicone replica technique and measured at 8 sites per specimen. Wilcoxon's signed-ranks test was used for statistical analysis(${\alpha}=0.05$). Results: Means of marginal adaptations were $95.1{\mu}m$ for 3DP group and $75.9{\mu}m$ for CAST group(p < 0.000). Conclusion : However, the mean of the 3DP group was within the clinical tolerance suggested by the previous researchers. Based on this, dental prosthesis fabricated by 3D printing technology is considered to be clinically acceptable.