• Title/Summary/Keyword: digital denture

Search Result 94, Processing Time 0.029 seconds

Multiple fixed implant-supported prosthesis using temporary denture and scannable healing abutment: a case report (임시의치와 스캔가능한 치유지대주를 이용한 고정성 임플란트 보철 수복 증례)

  • Hyung-Jun Kim;Hyeon Kim;Woo-hyung Jang;Kwi-dug Yun;Sang-Won Park;Hyun-Pil Lim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.250-259
    • /
    • 2023
  • The use of digital technology in fixed prosthetic treatment using implants enables predictive treatment through diagnosis and virtual surgery by integrating clinical and radiological information of patients. Existing digital scanning methods require several components to be removed, such as removing the healing abutment and connecting the scan body. In the scannable healing abutment developed in consideration of this point, scanning is performed directly on the healing abutment, maintaining soft tissue sealing and simplifying scanning. Digital technology can also be used when obtaining the intermaxillary relationship. Recently, various digital technologies have been reported to acquire the intermaxillary relationship of edentulous patients using surgical guides, patient-specific scanning devices, or scans of the inside of temporary dentures. In this case, the implant-supported fixed prosthesis treatment was performed through scanning the scannable healing abutment and the inner side of the temporary denture to obtain the intermaxillary relationship, thereby simplifying the treatment process and obtaining aesthetically and functionally excellent clinical results.

Fabrication of complete denture using 3D printing: a case report (3D 프린팅을 이용한 양악 총의치 제작 증례)

  • Lee, Eunsu;Park, Chan;Yun, Kwidug;Lim, Hyun-Pil;Park, Sangwon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.202-210
    • /
    • 2022
  • Recently with the advance in digital dentistry, the fabrication of dentures using computer-aided design and computer-aided manufacturing (CAD-CAM) is on the rise. The denture designed through a CAD software can be produced in a 3-dimensional manufacturing process. This process includes a subtractive processing method such as milling and an additive processing method such as 3D printing and in which it can be applied efficiently in more complex structures. In this case, complete dentures were fabricated using Stereolithography (SLA)-based 3D printing to shorten the production time and interval of visits in patient with physical disabilities due to cerebral infarction. For definitive impression, the existing interim denture was digitally replicated and used as an individual tray. The definitive impression obtained with polyvinyl siloxane impression material was including information about the inclination and length of the maxillary anterior teeth, vertical dimension, and centric relation. In addition, facial scan data with interim denture was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a FDA-approved liquid photocurable resin. The denture showed adequate retention, support, and stability, and results were satisfied functionally and aesthetically.

'All-on-4' fixed implant supported prosthesis restoration using digital workflow: a case report (Digital workflow를 활용한 'All-on-4' 임플란트 지지 고정성 보철물 수복 증례)

  • Sungwoo Ju;Seoung-Jin Hong;Janghyun Paek;Kwantae Noh;Ahran Pae;Kung-Rock Kwon;Hyeong-Seob Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.316-327
    • /
    • 2023
  • In the case of fully edentulous patients with severe alveolar bone resorption, the consideration of 'All-on-X' implant-supported fixed prosthesis after placing four or more implants in the anterior maxilla is possible. Recent advancements in digital dentistry have enabled systematic and predictable treatment in all phases, including diagnosis, surgery, and prosthesis fabrication. By incorporating digital dentistry techniques such as digital complete denture, implant surgical guides, facial scanning into the conventional restoration process, it is possible to reduce the complexity of the prosthesis fabrication and effectively achieve the transition from provisional prosthesis to definitive prosthesis in terms of both aesthetics and function.

Analysis of deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a DLP printer (DLP 프린터로 출력한 임시의치용 전악 인공치아의 후경화에 따른 변형 분석)

  • Kim, Dong-Yeon;Lee, Gwang-Young
    • Journal of Technologic Dentistry
    • /
    • v.43 no.2
    • /
    • pp.48-55
    • /
    • 2021
  • Purpose: This study aimed to analyze deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a digital light processing (DLP) printer. Methods: An edentulous model was prepared and an occlusal rim was produced. The edentulous model and occlusal rim were scanned using a model scanner. A complete denture was designed using a dental computer-aided design, and the denture base and artificial tooth were separated. Ten complete arch artificial teeth were printed using a 3D printer (DLP). Complete arch artificial teeth was classified into the following three groups: a group no post-curing (NC), a group with 10 minutes post-curing (10M), and a group with 20 minutes post-curing (20M). Specimens were scanned using a model scanner. The scanned data were overlapped with the reference data. Statistical analysis was performed using one-way ANOVA analysis of variance, Kruskal-Wallis test, and Mann-Whitney U test (α=0.05). Results: Regarding the overall deviation of complete arch artificial teeth, the NC group showed the lowest mean deviation of 111.13 ㎛ and the 20M group showed the highest mean deviation of 131.03 ㎛. There were statistically significant differences among the three groups (p<0.05). Conclusion: The complete arch artificial tooth showed deformation due to post-curing. In addition, the largest shrinkage deformation was observed at 10 minutes of post-curing, whereas the least deformation was observed at 20 minutes.

Effect of post-rinsing time and method on accuracy of denture base manufactured with stereolithography

  • Katheng, Awutsadaporn;Kanazawa, Manabu;Komagamine, Yuriko;Iwaki, Maiko;Namano, Sahaprom;Minakuchi, Shunsuke
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.45-55
    • /
    • 2022
  • PURPOSE. This in vitro study investigates the effect of different post-rinsing times and methods on the trueness and precision of denture base resin manufactured through stereolithography. MATERIALS AND METHODS. Ninety clear photopolymer resin specimens were fabricated and divided into nine groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5, 10, and 15 min using three methods-automated, ultrasonic cleaning, and hand washing. The specimens were polymerized for 30 min at 40℃. For trueness, the scanned intaglio surface of each SLA denture base was superimposed on the original standard tessellation language (STL) file using best-fit alignment (n = 10). For precision, the scanned intaglio surface of the STL file in each specimen group was superimposed across each specimen (n = 45). The root mean square error (RMSE) was measured, and the data were analyzed statistically through one-way ANOVA and Tukey test (α < .05). RESULTS. The 10-min automated group exhibited the lowest RMSE. For trueness, this was significantly different from specimens in the 5-min hand-washed group (P < .05). For precision, this was significantly different from those of other groups (P < .05), except for the 15-min automated and 15-min ultrasonic groups. The color map results indicated that the 10-min automated method exhibited the most uniform distribution of the intaglio surface adaptation. CONCLUSION. The optimal postprocessing rinsing times and methods for achieving clear photopolymer resin were found to be the automated method with rinsing times of 10 and 15 min, and the ultrasonic method with a rinsing time of 15 min.

Utilization of digital technology in fabricating mandibular implant overdenture for skeletal class II edentulous patient: A case report (2급 악간관계를 보이는 하악 무치악 환자에서 디지털 진단기술을 이용한 임플란트 피개의치 수복증례)

  • Lee, Yeun-Yi;Hong, Seoungjin;Paek, Janghyun;Noh, Kwantae;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.364-373
    • /
    • 2019
  • Unlike class I patients, skeletal class II patients have unstable occlusion thus leading to instability of mandibular complete denture. Therefore, mandibular implant overdenture has been the standard of care due to its advantages in stability and retention. The types of attachments can be divided into two categories: solitary and bar type. The indications vary between two categories. In this clinical report, digital technology was utilized from the implant planning to the choice of appropriate attachment. Implants were placed at the desired location as previously planned in terms of angle and depth. Maxillary removable partial denture and mandibular implant overdenture are expected to have fair prognosis.

Fabrication of complete dentures made with monolithic discs through CAD/CAM using facial scan data and individual tray duplicating temporary denture: a case report (안면스캔 데이터와 임시의치를 복제한 개인 트레이를 활용하여 CAD/CAM을 통한 monolithic disc로 제작한 총의치 수복: 증례 보고)

  • Ju Hyun Kim;Soo-Yeon Shin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.3
    • /
    • pp.158-167
    • /
    • 2023
  • As digital technology has advanced in the field of dentistry, the use of computer-aided design/computer-aided manufacturing (CAD/CAM) has brought changes to the stages of dental treatment. The use of CAD/CAM technology in dental restoration offers clinical efficiency and convenience by reducing production time and appointment intervals, while also simplifying the fabrication process to reduce errors. In this case, digital replication and printing of temporary teeth were used to aid a patient with complex medical histories and physical disabilities. The final impression obtained with silicone impression material included information on the vertical dimension, centric relation, and the angle and length of the anterior teeth, which shortened the production time and appointment intervals and increased patient satisfaction. The final restoration was fabricated using milling and monolithic disc techniques, demonstrating appropriate stability, retention, and support, resulting in functional and aesthetic satisfaction.

Fabrication of removable partial denture on scleroderma patient using 3-dimensional intraoral scanner (전신성 피부경화증 환자에서의 3차원 구강스캐너를 이용한 가철성 국소의치 제작 증례)

  • Kim, Ung-Gyu;Han, Jung-Suk;Yoon, Hyung-In;Yeo, In-Sung Luke
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.116-125
    • /
    • 2021
  • A three-dimensional (3D) intraoral scanner, which is one of the major developments in digital dentistry, is widely used in fixed prosthodontics. The application of intraoral scanner is now increasing in removable prosthodontics. Sclerotic change induced by scleroderma causes the limitation of mouth opening and multiple loss of the teeth. Conventional prosthodontic procedures are challenging for patients with this disease. This study showed a case of digital approach to the removable prosthodontic treatment of a patient who had the scleroderma and the consequent microstomia. At the provisional stage, the optical impression of patient's oral structures was digitally obtained. Using a 3D printer, the provisional dentures were fabricated. After extraction of hopeless tooth, the definitive digital impression was taken and the metal frameworks were fabricated, based on the data acquired from the impression. The definitive removable partial dentures were completed and delivered to the patient, who was satisfied with the prostheses.

A Feasibility Study for the Development of Dental Technology curriculum (Focusing on Daegu-Gyeongbuk Area) (치기공과 교육과정의 타당성에 관한 연구 - 대구.경북지역을 중심으로 -)

  • Kim, Jeong-Sook;Park, Kwang-Sig;Kim, Won-Gi
    • Journal of Technologic Dentistry
    • /
    • v.34 no.2
    • /
    • pp.165-177
    • /
    • 2012
  • Purpose: The purpose of this study is to lay the groundwork for the development of appropriate training courses for a rapidly changing digital technology in the field of Dental technology. Methods: The subjects of this study were dental technicians, dental technology students, a professor of dental technology in Daegu and Gyeongbuk area and a self-administered structured questionnaire survey was conducted for 350 randomly selected people. Collected data were analyzed using SPSS Win 17.0 statistics program and analysis techniques include the frequency, percentage and cross-analysis. Results: The results of the survey are as follows. The usefulness of Major subjects was Full Denture laboratory (4.72 points), Dental Morphology (4.71 points), Crown and Bridge laboratory (4.69 points) in the instructor's group. The usefulness of Major subjects was Dental Morphology (4.56 points), Full Denture (4.36 points), Crown and Bridge laboratory (4.69 points) in the student's group. The usefulness of Major subjects was Dental Morphology (4.58 points), Dental Morphology laboratory (4.34 points), Partial Denture laboratory (4.30 points) in the dental technician's group. Subject with the highest usefulness of required course to open was CAD/CAM lecture and laboratory, the highest proportion of 91.2% and Implant laboratory was very useful (91.2%) in the instructor's group. Subject with the highest usefulness of required course to open was CAD/CAM lacture and laboratory, the highest proportion of 90.0% and Implant laboratory was very useful (91.2%) in the student's group. Subject with the highest usefulness of required course to open was CAD/CAM lacture and laboratory, the highest proportion of 91.2% and Implant laboratory was very useful (90.2%) in the dental technician's group. Conclusion: Semester of the subjects was required establishment of CAD/CAM lecture and laboratory in the third year first semester (85.1%) and Implant laboratory in the third year second semester the third year was the highest proportion of 94.1% in the instructor's group. 87.0% of students need to open CAD/CAM lacture and laboratory in the third year first semester, Implant laboratory in the third year second semester the third year was the highest proportion of 85.0% in the student's group. Semester of the subjects was required establishment of CAD/CAM lecture and laboratory in the third year first semester (81.0%) and Implant laboratory in the third year second semester the third year was the highest proportion of 80.0% in the dental technician's group.

Fixed prosthodontic rehabilitation of maxillary posterior teeth using functionally generated path technique and intraoral digital scan: Case report (Functionally generated path technique 및 구내 디지털 스캔을 이용한 상악 구치부의 고정성 보철 수복 증례)

  • Kim, Sung-Ho;Lee, Jonghyuk;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.228-238
    • /
    • 2020
  • In order to deliver fixed partial denture to a patient successfully, dentist must take into many considerations beforehand. Patient's occlusal pattern should be fully understood before delivering any type of prosthesis, whether it's canine guidance or group function occlusion. In order to do so, movement of mandible should be recorded precisely. Introduced by Meyers in 1933, functionally generated path technique (FGP) has been successfully used to record mandibular movement with various materials, such as wax, and utilize it in fabricating precise prosthesis. In the following cases, patients showed secondary caries or endodontic-periodontic lesion on maxillary molars. Root canal treatment and subgingival curettage were done for each patient. Since the long term prognosis of each tooth was questionable, lateral force should be minimized. In order to do so, FGP technique was used to record mandibular movements precisely. Instead of using conventional plaster impression, intra-oral scanning of wax tracing was done to fabricate prosthesis efficiently. After delivery of fixed partial denture, favorable outcome was obtained.