Clinical Usefulness of Digital ECG Recorder in Dogs : 4 Cases (디지털 심전도기의 임상적 적용 예 : 4 증례)

  • Moon, Hyeong-Sun;Lee, Seung-Gon;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.218-224
    • /
    • 2007
  • Digital electrocardiogram (ECG) recorders are rapidly replacing to conventional paper ECG recorders. Digital ECG recorders have several advantages over conventional type ECG recorders, including better capability for data storage, better portability and better applicability in clinical settings. In this study, we presented 4 case studies related to cardiac rhythm disturbances, which were diagnosed and managed using a digital ECG recorder.

A Study on Developement of Portable Digital Bio-signal Recorder (디지털 휴대용 생체 기록계 개발에 관한 연구)

  • Lee, H.J.;Chun, T.Y.;Yun, C.H.;Huh, W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.109-113
    • /
    • 1993
  • In this paper, we devised a simple portable digital recorder for a day life ECG signal recording. The system are consisted of ECG amp. part, signal conditioning part. A/D converter, data compression part and digital memory part. An ADPCM algorithm used at data compress part for 50% of data reduction. The maximum lengths of recording times take 3 hours in 1 mega byte memory.

  • PDF

Design and Implementation of a Personalized Broadcasting System based on TV-Anytime (TV-Anytime 기반 맞춤형 방송 전송 시스템 설계 및 구현)

  • Yang Seung-Jun;Lee HeeKyung;Kim Jae-Gon;Hong Jinwoo
    • Journal of Broadcast Engineering
    • /
    • v.9 no.4 s.25
    • /
    • pp.345-356
    • /
    • 2004
  • In this paper, we present a design and implementation of a personalized broadcasting system using TV-Anytime metadata for providing personalized services. The TV-Anytime specifies metadata schema, metadata coding and delivery, and provides service models to provide personalized broadcasting content services at anytime when users want to consume using metadata, which includes ECG (Electronic Content Guide) and content descriptive information in a PDR (Personal Digital Recorder)-centric environment. The proposed personalized broadcasting system consists of a server that provides metadata binary-coding, encapsulation and multiplexing, and a client terminal that takes charge of de-multiplexing, metadata decoding, and metadata processing for personalized content accessing and consumption. This paper presents the details of the design of each functional module, and the evaluation results with a set of service scenarios in an end-to-end broadcasting test-bed.

A Study on the Implementation of Real-time Digital Filter System for the Baseline Wandering Elimination (기저선 변동 제거를 위한 실시간 디지털 필터 시스템 구현에 관한 연구)

  • 윤승구;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.512-515
    • /
    • 2001
  • The heifer electrocardiograph is a widely progressing research which is used in judgement to existence for a heart disease and analyzes electric potential changes of heart movement during continuous living of everyday after attaching to body portable holler recorder for twenty-four hours. In order to obtain electrocardiogram clearly, it must eliminate that 60Hz power line interference, baseline wandering, noise of muscle constriction. In holter electrocardiogram, the most big problem which is recorded signal of ECG(electrocardiogram) is a baseline wandering elimination, which is occurred by rhythm of respiration and muscle constriction of part from attaching to an electrode. Such baseline is roughly irregular wandering and shaking up and down therefore the part of baseline wandering elimination is very important because it is difficult of ECG diagnosis. In this study, it is stabilized baseline wandering in analog part as implementation f real-time signal processing digital filter so it is applicable to analyze patient's heart disease by way of design of baseline wandering elimination system.

  • PDF

Design and Implementation of a TV-Anytime Metadata Authoring Tool for Personalized Broadcasting Services (개인형 데이터방송 서비스를 위한 TV-Anytime 메타데이터 저작도구 설계 및 구현)

  • Jun Dong-San;Kim Min-Je;Lee Han-Kyu;Yang Seung-Jun
    • Journal of Broadcast Engineering
    • /
    • v.11 no.3 s.32
    • /
    • pp.284-301
    • /
    • 2006
  • In this paper, we present a design and implementation of a TV-Anytime metadata authoring tool for providing personalized data-broadcasting services. The TV-Anytime specifies metadata schema, metadata coding and delivery, and provides service models to provide personalized broadcasting content services at anytime when users want to consume using metadata including ECG (Electronic Content Guide) and content descriptive information in a PDR (Personal Digital Recorder)-centric environment. In spite of a useful services based on TV-anytime metadata, the metadata authoring still remains as a harassing and time consuming task. For easy metadata authoring, the proposed metadata authoring provides the following key functionalities: metadata visualization, media access, and semi-automatic method for editing segment related metadata.

Effect of Acupuncture at PC6(Neiguan) and SP4(Gongsun) points on Autonomic Nervous System in Healthy Adults (내관(內關)(PC6).공손(公孫)(SP4) 자침이 정상인의 자율신경계에 미치는 영향 연구)

  • Rheu, Kyoung-Hwan;Im, In-Hwan;Kim, Dong-Hyun;Na, Byong-Jo;Lee, Beom-Jun;Park, Seong-Uk;Ko, Chang-Nam
    • The Journal of Internal Korean Medicine
    • /
    • v.27 no.3
    • /
    • pp.698-705
    • /
    • 2006
  • Objectives : This study was designed to investigate the effect of PC6 and SP4 on autonomic nerve system in healthy adults. Methods : 22 healthy adults were recruited and randomized into the study group or control group. The study group (real acupuncture group) was acupuncturcd on PC6 and SP4. The control group (sham acupuncture group) was acupunctured superficially near PC6 and SP4 but not the exact points. The subjects rested for 10 minutes, and were then acupunctured. After 15 minutes, acupuncture needles were removed and the subjects rested for another 15 minutes. Heart rate variability(HRV) was continuously measured during the study period by FM-150 (digital Holter ECG recorder). Results : In the real acupuncture group. LF(low frequency) significantly decreased during the acupuncture period(p<0.05). LF/HF ratio also had a significant decrease during acupuncture period and the decrease was maintained during the post-treatment period as compared with the pre-treatment period. In the sham acupuncture group. LF significantly increased during the acupuncture period but LF/HF ratio had no significant changes. Conclusions : The results suggest that acupuncture on PC6 and SP4 can increase parasympathetic activity and balance autonomic nervous system.

  • PDF

Effects of Acupuncture on Autonomic Nervous System in Normal Subjects under Mental Stress (내관(內關)-공손(公孫) 자침이 스트레스 상태의 정상성인 자율신경계에 미치는 영향)

  • Park, Seong-Uk;Jung, Woo-Sang;Moon, Sang-Kwan;Park, Jung-Mi;Ko, Chang-Nam;Cho, Ki-Ho;Kim, Young-Suk;Bae, Hyung-Sup
    • The Journal of Korean Medicine
    • /
    • v.29 no.2
    • /
    • pp.107-115
    • /
    • 2008
  • Objectives: The objective of this study was to assess the effects of acupuncture applied at PC6 and SP4 points on heart rate variability (HRV) in normal subjects under mental stress Methods: 24 healthy male subjects were recruited and randomized to a treatment group (12 subjects) or a control group (12 subjects). Both groups performed a mental arithmetic stress test and then acupuncture needles were inserted on PC6 and SP4 for the study group. In the control group, they took sham acupuncture as a control. Heart rate variability (HRV) was measured during the whole study period by FM-150 (digital Holter ECG recorder). Results: In the both groups, low frequency (LF) power and ratio of low frequency to high frequency (LF/HF) was significantly increased after mental stress. Acupuncture induced significant decrease in low frequency (LF) power and ratio of low frequency to high frequency (LF/HF) which were increased after mental stress test. But sham acupuncture induced no changes. Results: In both groups, low frequency (LF) power and ratio of low frequency to high frequency (LF/HF) significantly increased after mental stress. Acupuncture induced significant decrease in low frequency (LF) power and ratio of low frequency to high frequency (LF/HF) which increased after mental stress test. In contrast, sham acupuncture induced no changes. Conclusions: Acupuncture on PC6 and SP4 could be useful to decrease sympathetic activity and balance autonomic nervous system for those who are under stress.

  • PDF