• Title/Summary/Keyword: diffuser effect

Search Result 145, Processing Time 0.025 seconds

Conceptual Study of a Low-Speed Wind Tunnel for Performance Test of Wind Turbine (풍력터빈 성능시험을 위한 저속풍동 개념연구)

  • Kang, Seung-Hee
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.19 no.4
    • /
    • pp.24-29
    • /
    • 2011
  • Conceptual study of an open-circuit type low-speed wind tunnel for performance test of wind turbine blade and airfoil is conducted. The tunnel is constituted of a settling chamber, a contraction, closed test section, a diffuser, two corners, a cross leg and a fan and motor. For the performance test, the closed test section width of 1.8 m, height of 1.8 m and length of 5.25 m is selected. The contraction ratio is 9 to 1 and maximum speed in the test section is 67 m/sec. Input power in the tunnel is about 238 kW and its energy ratio is 3.6. The wind tunnel designed in present study will be an effective tool in research and development of wind turbine and airfoil.

A Study on Optical Losses for Tubular LED Lamp's Components (직관형 LED램프의 구성부품별 광손실에 관한 연구)

  • Jeong, Hee-Suk;Park, Chang-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.1-8
    • /
    • 2011
  • The high efficiency tubular LED lamp has been developed. But, it occurs optical losses in consists of LED package, module, diffuser etc.. By Measuring the tubular LED lamp's luminous flux, we compared and analyzed about the effect of optical losses for each component and actually using measured luminous intensity distribution data, illuminance distribution was simulated by Relux. Optical losses are 24[%] from LED package to luminaire and the tubular LED lamp can be replaced with fluorescent lamp. In this paper, we could provide data for optimum lighting design by analyzing the optical characteristics for developing and propagating the tubular LED lamp.

Holographic setereograms using spatial light modulator (공간 광 변조기를 이용한 홀로그래픽 스테레오그램의 제작)

  • Kim, Eun-Seok;Kim, Nam
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.2
    • /
    • pp.86-92
    • /
    • 1998
  • Holographic stereograms were made using a geometrical method easily. Becausethe conventioal sampling metod which is used in cylinder type stereograms, divide the anales of the object so it can't offer a binocular parallax effect very well, and it is also difficult to afficult to apply to the plane type stereograms. In this paper, holographic stereograms were made by use of a new method for the calculation of the sampling number(here, sampliing angles), and the TFT LCD. In order to calculate the sampling angles, geometrical method was used and 2-D images were projected onto diffuser screen through TFT LCD. Result stereorgrams which aremade by a sampling method proposed in this ppaer give a accurate binocular parallax and have a sufficient viewing zone and show that it is possible to make 3-D movies.

  • PDF

Research for fabricating micro-size PMMA beads using Electro-hydrodynamic process (Electro-hydrodynamic 프로세스를 이용한 PMMA 마이크로 비드 제조방법에 대한 연구)

  • Park, Jong-Ha;Lee, Jun-Hee;Kim, Wan-Doo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1509-1514
    • /
    • 2008
  • To fabricate microsized poly(methyl methacrylate)(PMMA) beads of uniform size and density on poly(ethylene terephthalate) (PET) fis, we introduce an electro spraying technique that uses a target electrode applied with an ac electric fid. Using the apparatus and various material properties, we could obtain uniform size PMMA beads which were deposited on the thin PET film. The optical properties, transmittance and light diffusivity of the fis electro sprayed with the PMMA were characterized. The results show that the sprayed beads appear to act as a good optical diffuser, like microlenses. To understand the effect of process variables, applied field conditions and rheological properties, the morphological pictures of the deposited particles were investigated through the optical and scanning electron microscope.

  • PDF

The Inlet Shape Optimization of Aftertreatment System for Diesel Engine with Taguchi Method (다꾸치 방법을 이용한 디젤엔진용 후처리시스템의 입구부 형상 최적화)

  • Jung, Jong-Hwa;Kim, Jong-Hag;Kim, Sang-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.5
    • /
    • pp.145-151
    • /
    • 2012
  • New design of catalytic converter is proposed by optimization of DFSS (Design For Six Sigma) and DOE (Design Of Experiment) method which is based on taguchi matrix. As a result of the optimization of design of catalytic converter, this paper classifies Exhaust-downpipe shapes with 3 parameters to increase flow velocity uniformity of front catalytic substrate face from CFD results. after finishing with L9 Taguchi test matrix, it can be found the main effect of each design parameter of concept model, and optimal design level. in conclusion, it can be increase flow uniformity from 0.60 upto 0.80 with optimal diffuser shape for Turbo-charger.

A Study on the Microbubble Characteristics of Ozone to Improve Dissolution Efficiency (오존 용해효율 향상을 위한 미세기포 특성 연구)

  • Kim, Jin-Hoon;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.6
    • /
    • pp.47-53
    • /
    • 2009
  • Ozone is a strong oxidant and a powerful disinfectant. In general, it has been used in drinking water treatment during last 100years. Ozone dissolution features are defined by the two categories of ozone contactors, bubble-diffuser and sidestream ozone contactor. Currently, sidestream-injection systems are gaining in popularity but operating cost might be slightly higher. Sidestream ozone system dissolve ozone into a sidestream flow via an injection setup or in the main process flow stream in some sidestream arrangements. The sidestream flow is subsequently mixed with the main process flow stream, which is directed to a reation tank or pipeline for oxidation and disinfection reactions. The purpose of this study is to suggest optimal operating pressure, to figure out the static-mixer effect and to understand the microbubble characteristics of ozone to improve dissolution efficiency.

A Study for optimum design of Thermal Storage tank (성층축열조 최적설계를 위한 연구)

  • Jang Dong-Soon;Shin Mi-Soo;Kim Hey-Suk;Song Hye-Young;Lee Young-Soo;Lee Sang-Nam
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.127-132
    • /
    • 2002
  • Numerical and experimental works have been made in order to figure out the physical mechanism of thermal storage system for the determination of optimal design and to enhance the thermal efficiency of the system. To this end a computer program is developed and evaluated successfully against experimental data measured with a bench scale facility. Considering the thermal efficiency of storage is critically impaired by the mixing effect, the minimum flow mixing situation is calculated by the assumption of uniform plug-type flow as a reference condition. Further a parametric systematic calculations have been made for a hypothetical full-scale storage system with Fr, storage dimension, diffuser type and loading hour, etc.

  • PDF

Spiral Casing of a Volute Centrifugal Pump - Effects of the Cross Sectional Shape - (볼류트 원심펌프의 스파이럴 케이싱 - 단면 형상의 영향 -)

  • Jin, Hyun Bae;Kim, Myung Jin;Son, Chang Ho;Chung, Wui Jun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.4
    • /
    • pp.28-34
    • /
    • 2013
  • Centrifugal pump consists of a axis, a impeller and a spiral casing. The impeller is the most important component in centrifugal pump. But to minimize flow loss in discharge passage including spiral casing, the shape of spiral casing is very important also. So, to investigate the effect of shape of the spiral casing on performance curve of pump, the characteristics of spiral casing were studied through numerical analysis for centrifugal pump used on industry field. From the results the rectangular model was showed more loss than the others because of asymmetric flow field.

Hydraulic performance and flow resistance tests of various hydraulic parts for optimal design of a reactor coolant pump for a small modular reactor

  • Byeonggeon Bae;Jaeho Jung;Je Yong Yu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.1181-1190
    • /
    • 2023
  • Hydraulic performance and flow resistance tests were performed to confirm the main parameters of the hydraulic instrumentation that can affect the pump performance of the reactor coolant pump. The flow resistance test offers important experimental data, which are necessary to predict the behavior of the primary coolant when the circulation of the reactor coolant pump is stopped. Moreover, the shape of the hydraulic section of the pump, which was considered in the test, was prepared to compare the mixed-flow- and axial-flow-type models, the difference in the number of blades of the impeller and diffuser, the difference in the shape of the impeller blade and its thickness, and the effect of coating at the suction bell. Additionally, five models of the hydraulic part were manufactured for the experiments. In this study, the differences in performance owing to the design factors were confirmed through the experimental results.

바이오응용을 위한 압전 공진형 MEMS 소자

  • Kim Yong Bum;Kim Hyung Joon;Kang Ji-Yoon;Kim Tae Song
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.1-7
    • /
    • 2002
  • This papers describes the preparation and experimental results of a micro mass detection devices based on cantilever and a diffuser-type micro pump using screen printing thick-film technologies and Si micro-machining. PZT-PCW thick films were prepared by new hybrid method based on the screen printing. By applying these PZT-PCW piezoelectric thick films on actuator, a cantilever for mass detection sensor and a micropump for microfluidic element are successfully fabricated. Resonant frequency and displacement of PZT-PCW thick film actuator in air and in liquid are measured by laser vibrometer system as a function of actuator size. The resonant frequency of PZT-PCW thick film actuator in liquid decreases order of 1/2-1/4 due to damping effect. The sensitivity of cantilever is characterized by Au deposition method which has the mass loading effect such as adsorption of protein. The Sensitivity of PZT-0.12PCW thick film cantilever is proportional to detecting area.

  • PDF